Loading...
Town Center BP-LR010514CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94001422.0008 Service Date: April 30, 2001 Client: Excel Group, Inc. Attn: Bryan Peck 2639 Walnut Hill Ln #218 Dallas TX 75229 890~t Carpenter Finny., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: M~ Project: ~dP,ark?::~ . Project Number: '9401;~11132' Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 11:40am Supplier: Redi-Mix Track No: 287 LMix I.D. No.: 732 Plant: 5 Ticket No: 51580 Sample Information Sample Time: 2:15pm Technician: Roy Montgomery Weather Conditions: Clear Accumulative Yards: 150 Placement Method: Direct discharge Sample Locations: See placement location Placement Location: Paving, NW side of project Sample location: 200' S of north curb, 30' E of W curb Field Test Data Test Result Specification Test Method Slump, inches: 6.00 3-5 ASTM C-143 Air Content, %: 3-6 ASTM C-172 Concrete Temperature, o F: 90 ASTM C-39 Ambient Temperature, o F: 78 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Date Test Load Strength No. ID (inches) Tested (days) (lbs) (psi) 1 1 6.00 0510712001 7 76,840 2,720 1 2 6.00 05/07/2001 7 83,110 2,940 Average 2,830 1 3 05/28/2001 28 1 4 05/28/2001 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Roy Montgomery Report Distribution: (1) Exce~ G~oup, Inc. (1) City of Coppell - Engr Dept (1) City of Coppell - BIdg Insp Reviewed by: Senior Project Engineer The tests were performed in general accordance with applicable ASTM test methods. This report is exclusively for the usa of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transrnittod herein are only applicable to the actual saropies tested at the location(s) referenced and are not necessarily indicative of the preper~ies of other apparently similar or identical materials. CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94001422.0010 Service Date: May 1, 2001 Client: Excel Group, Inc. Attn: Bryan Peck 2639 Walnut Hill Ln #218 Dallas TX 75229 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: May 14, 2001 Project: Town Center Business Park 205 East Parkway Blvd Coppell, Texas Project Number: 94001422 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 1:04pm Supplier: Redi-Mix Track No: 223 Mix i.D. No.: 732 Field Test Data Plant: 91 Ticket No: 137868 Sample Information Sample Time: 1:30pm Technician: Albert Garcia Weather Conditions: Clear Accumulative Yards: 30 Placement Method: Direct discharge Sample Locations: 30' South of entrance Placement Location: East side fimlane Test Result Specification Test Method Slump, inches: 6.00 3-5 ASTM C-143 Air Content, %: 4.1 3-6 ASTM C-172 Concrete Temperature, o F: 82 ASTM C-39 Ambient Temperature, o F: 76 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Date Test Load Strength No. ID (inches) Tested (days) (lbs) (psi) 1 1 6.00 05/08/2001 7 80,510 2,850 1 2 6.00 05/08/2001 7 78,140 2,760 Average 2,810 1 3 05/29/2001 28 1 4 05/29/2001 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Albert Garcia Report Distribution: (1) Excel Group, thC. (1) City of Co,pail - Engr Dept (I) City of Coppell - Bldg Insp Reviewed by: Eric J Cleveland, P E Senior Project Engineer The tests were performed in general accordance with applicable ASTM test methods. This report is exclusively for the use of the client indicated above and shall not be repreduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the aotual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.