Loading...
Town Center BP-LR010511 LABORATORY COMPACTION CHARACTERISTICS OF SOIL Report Number: 94001422.0009 Service Date: April 30, 2001 8901 Carpenter Frwy., Suite//100 Dallas, Texas 75247 (214) 630-1010 Client: Excel Group, inc. Attn: Bryan Peck 2639 Walnut Hill Ln #218 Dallas TX 75229 Report Date: Project: Project Number: May 11, 2001 Town Center Business Park 205 East Parkway BIvd Coppell, Texas 94001422 Material Information Contractor: Excel Source of Material: Treated on-site Proposed Use: Paving Subgrade Laboratorl/ Test Data Test Procedure: Test Method: Sample Preparation: Rammer Type: Maximum Dry Unit Weight, pcf: 114.0 Optimum Water Content, %: 14.0 ASTM D-698 ASTM D-698 ASTM D-698 ASTM D-698 Sample Information Sampled By: Montgomery, Roy Sample Location: Native Sample Description: Dk brown sandy clay w/gravel (lime treated) Result Specifications Liquid Lim, it: 37 Plastic Limit: 22 Plasticity Index: 15 % Passing #200: % Passing #40: Moisture Density Relations Zero Air Voids Curve for assumed specific gravity 2.65 \\ \\ Services- Moisture-Density Relations Technician: Roy Montgomery Report Distribution: (1) Excel Group, Inc. (1) City of Coppell - Engr Dept (1) City of Coppe]l - BIdg Insp Reviewed by: Eric J. Cleveland, P.E Senior Project Engineer The tests were perlormed in general accordance with applicable ASTM test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval ol~ Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarity indicative of the propedies of other apparently similar or identical materials.