Loading...
Blackberry Farm-PN240517AN EXTERIOR DESIGN PACKAGE FROML0.00SHEET INDEXPROJECT NUMBER:ISSUE DATE: SHEET SIZE: 24" x 36"2404905.17.2024PRELIMINARY SET (NOT FOR CONSTRUCTION)SHEET TITLESHEET NO.CENTRAL PARK AT BLACKBERRY FARM 1011 BLACKBERRY DRIVE, COPPELL, TX234 561123456ABCDEFABCDEF214.970.7565support@blountdesigns.com5600 Tennyson Pkwy, Suite 335Plano, Texas 75024L0.00SHEET INDEXSHEET INDEXL0.01NOTES, LEGENDS, & SELECTIONSL1.01DEMOLITION & TREE PROTECTION PLANL2.01SITE PLANL2.01ADIMENSIONAL CONTROL PLANL3.01GRADING PLANL3.01ADRAINAGE PLANL4.01SITE DETAILSL5.01POOL OVERVIEWL5.02POOL LAYOUT PLANSL5.03POOL DETAILSL7.00PLANTING SCHEDULE & DETAILSL7.01PLANTING PLANL8.01IRRIGATION PLANL9.01LIGHTING PLANL10.01FURNISHINGS & APPLIANCESL6.01STRUCTURE OVERVIEWL6.02STRUCTURE PLANSL6.03STRUCTURE DETAILS L0.01NOTES, LEGENDS &SELECTIONSLOT COVERAGE & IMPERMEABLE CALCULATIONSLOT SIZESLAB COVERAGEREMAINING LOT COVERAGETOTAL COVERAGELOT CATEGORYPROPOSED IMPERVIOUSMAX. IMPERVIOUS ALLOWED0 - 6,000 SF3,600 SF>SFSFSFSFXXXXX SF OR X %8' HT. COLUMN6' HT. COLUMN4' HT. COLUMNEXISTING WOOD FENCEEXISTING IRON FENCEPROPOSED WOOD FENCEPROPOSED IRON FENCEGATE MOTOREX-IRONEX-IRONEX-WOODEX-WOODXXXXXFENCE LEGENDA\CHVAC UNITP.E.POOL EQUIPMENTGMGAS METERGRGAS RISER INTO HOUSEEELECTRICAL METERWMWATER METERCOCLEAN OUTMHMAN HOLEIRDIRRIGATION DOUBLE CHECKIRVIRRIGATION VALVEMOGATE MOTORTCTRASH CANTWTOP OF WALLBWBOTTOM OF WALLTRTOP OF RISERBRBOTTOM OF RISERVIFVERIFY IN FIELDTYPTYPICALPTPATIO TOPPINGOCON CENTEREQEQUAL DISTANCEADAREA DRAINCBCATCH BASINCJCONTROL JOINTEJ EXPANSION JOINTHPHIGH POINTLPLOW POINTPOBPOINT OF BEGINNINGTCTOP OF COLUMNTFTOP OF FOOTINGVBVOLLEYBALLBBBASKETBALLUMUMBRELLAMBMAILBOXTPBTOP OF POOL BEAMTPCTOP OF POOL COPINGABBREVIATIONSEXISTING ELEVATIONPROPOSED ELEVATIONFLOW DIRECTION00"00GRADING LEGENDEXISTING MINOR TOPO.EXISTING MAJOR TOPO.PROPOSED MINOR TOPO.PROPOSED MAJOR TOPO.SWALESWALESWALEDRAINAGE LEGENDDRAINAGE SLEEVE4" DRAIN LINE6" DRAIN LINE8" DRAIN LINE12" DRAIN LINE4" PERFORATED DRAIN LINE6" PERFORATED DRAIN LINEFRENCH DRAINFRENCH DRAINDOWNSPOUTAREA DRAINCHANNEL DRAINSUMP PUMPPOP-UPDRAIN VENTCURB CASTINGT-DRAIN12"18"24"1.ALL EXISTING SITE CONDITIONS & UTILITIES ARE TO BE VERIFIED IN FIELD PRIOR TOCONSTRUCTION. LANDSCAPE DESIGNER SHALL NOT BE HELD ACCOUNTABLE FOR ANYDISCREPANCIES PERTAINING TO SURVEY OR EXISTING CONDITIONS.SITE CONDITIONS NOTEEXISTING GASEXISTING ELECTRICALEXISTING SEWEREXISTING WATERPROPOSED GASPROPOSED ELECTRICALPROPOSED SEWERPROPOSED WATERGASGASGASGASGASGASGASELECELECELECELECELECELECELECSEWERSEWERSEWERSEWERSEWERSEWERSEWERWATERWATERWATERWATERWATERWATERWATEREX.GASEX.GASEX.GASEX.GASEX.GASEX.GASEX.GASEX.ELECEX.ELECEX.ELECEX.ELECEX.ELECEX.ELECEX.ELECEX.SEWEREX.SEWEREX.SEWEREX.SEWEREX.SEWEREX.SEWEREX.WATEREX.WATEREX.WATEREX.WATEREX.WATEREX.WATEROVERHEAD EASEMENTOHEOHEOHEOHEOHEOHEOHEWATER METERWATER VALVEGAS METERWMGMMANHOLEMHHOSE BIBGAS RISERELECTRIC PANELCLEAN OUTA/C UNITGRETRASH CANFIRE HYDRANTF HUTILITY POLEUPMBMAILBOXUTILITY LEGENDSTANDARD PIER/FOOTING3' DEEP PIER/FOOTING5' DEEP PIER/FOOTINGPIER/FOOTING W/ STEEL PLATEHELICAL PIERx'FOOTING & PIER LEGENDLIGHTING NOTES:1.LIGHTING SYMBOLS FOR COORDINATION/REFERENCE ONLY. REFER TO L9.01DRAWINGS/SPECIFICATIONS FOR DETAILS, FIXTURE TYPES, INSTALLATION, ANDENGINEERING.PLANTING NOTES:1.THE CONTRACTOR SHALL STAKE OUT ALL TREE LOCATIONS IN THE FIELD FOR REVIEW BY THELANDSCAPE ARCHITECT BEFORE PLANTING.2.PLANTING BEDS SHALL BE STAKED FOR REVIEW BY THE LANDSCAPE ARCHITECT BEFOREEXCAVATION AND BED PREPARATION.3.THE LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION OFALL UNDERGROUND UTILITIES, PIPES, STRUCTURES, AND LINE RUNS IN THE FIELD BEFORETHE INSTALLATION OF ANY PLANT MATERIAL.4.IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ADVISE THE LANDSCAPE ARCHITECT OFANY CONDITION FOUND ON THE SITE THAT PROHIBITS INSTALLATION AS SHOWN ON THESEDRAWINGS.5.ALL PLANT MATERIAL SHALL BE MAINTAINED IN A HEALTHY AND GROWING CONDITION ANDMUST BE REPLACED WITH PLANT MATERIAL OF THE SAME VARIETY AND SIZE IF DAMAGED,DESTROYED, OR REMOVED.6.THE LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR FINE GRADING AND REMOVALOF DEBRIS BEFORE PLANTING IN ALL AREAS.7.FINAL FINISH GRADING SHALL BE REVIEWED BY THE LANDSCAPE ARCHITECT. THE LANDSCAPECONTRACTOR SHALL BE RESPONSIBLE FOR ANY ADDITIONAL TOPSOIL REQUIRED TO CREATEA SMOOTH CONDITION BEFORE PLANTING.8.ALL PLANT QUANTITIES LISTED ARE FOR INFORMATION ONLY. IT IS THE CONTRACTOR’SRESPONSIBILITY TO PROVIDE FULL COVERAGE IN ALL PLANTING AREAS AS SPECIFIED IN THEPLANT SCHEDULE AND VERIFY ALL QUANTITIES.9.REFER TO PLANS FOR STEEL EDGING LAYOUT/LOCATIONS.10.ALL PLANT MATERIAL SHALL CONFORM TO THE SPECIFICATIONS AND SIZES GIVEN IN THEPLANT LIST AND SHALL BE NURSERY-GROWN IN ACCORDANCE WITH THE AMERICANSTANDARD FOR NURSERY STOCK. THE LATEST EDITION OF THE AMERICAN ASSOCIATION OFNURSERYMEN STANDARDS. ANY PLANT SUBSTITUTION SHALL BE APPROVED BY THELANDSCAPE ARCHITECT BEFORE PURCHASE.11.THE CONTRACTOR IS REQUIRED TO PERFORM A PERCOLATION TEST FOR EACH TREE PITBEFORE INSTALLATION. IF DRAINAGE DOES NOT OCCUR WITHIN 24 HOURS, THE CONTRACTORWILL BE REQUIRED TO PROVIDE A GRAVEL SUMP, FILTER FABRIC, AND STANDPIPE. ALLSUMPS SHOULD BE INCLUDED IN THE BASE BID AND PROVIDED AS A DEDUCT ALTERNATE IFNOT REQUIRED AFTER THE PERCOLATION TEST IS PERFORMED.12.THE LANDSCAPE CONTRACTOR IS RESPONSIBLE FOR ANY COORDINATION WITH OTHERCONTRACTORS ON-SITE AS REQUIRED TO ACCOMPLISH ALL PLANTING OPERATIONS.13.AN AUTOMATIC IRRIGATION SYSTEM SHALL BE PROVIDED FOR ALL PLANTING AREAS. OVERSPRAY ON STREETS AND WALKS IS PROHIBITED.CONCRETE NOTES:1.CAST-IN-PLACE CONCRETE SHALL MEET THE FOLLOWING REQUIREMENTS:-MINIMUM 3,000 PSI COMPRESSIVE STRENGTH AT 28 DAYS.-AGGREGATES: ASTM C33, MAXIMUM ¾" IN SIZE.-SLUMP: 3 TO 5 INCHES.-AIR CONTENT: 4 TO 6 PERCENT BY VOLUME.2.CONCRETE THICKNESS:-PEDESTRIAN AREAS = 4" THICK.-VEHICULAR AREAS = 6" THICK.3.CONCRETE REINFORCING:-4" THICK = #3'S @ 18" O.C., BOTH WAYS.-6" THICK = #3'S @ 18" O.C., BOTH WAYS.4.SAW CUT JOINTS TO BE PLACED AS INDICATED ON PLANS TO A MINIMUM ½" DEPTH. REFER TOLAYOUT PLANS FOR EXACT LOCATIONS.5.EXPANSION JOINTS:-PLACE AT A MAXIMUM OF 20' O.C. AND COORDINATE WITH THE OVERALL PAVINGPATTERN AND SAW JOINTS.-PROVIDE 18" #4 SMOOTH DOWELS AT A MAXIMUM OF 18" ON CENTER. COAT ONE END OFTHE DOWEL TO PREVENT BONDING.-REFER TO LAYOUT PLANS FOR EXACT LOCATIONS.TREE PROTECTION NOTES:1.BEFORE HARDSCAPE WORK, HIRE A LICENSED ARBORIST TO ASSESS CONDITIONS AFFECTINGEXISTING TREES DURING CONSTRUCTION.2.PROTECT DESIGNATED TREES AND PLANTS AT THE SITE FROM CONSTRUCTION DAMAGE.3.ERECT 4-FOOT CHAIN-LINK FENCES AROUND TREES/PLANTS AS INDICATED ON PLANS.DISPLAY "KEEP OUT" SIGNS ON TREE PROTECTION ZONE (TPZ) FENCING.4.SUPERVISE EARTHWORK TO PREVENT DAMAGE TO CRITICAL ROOT ZONES.5.ASSIGN A MONITOR FOR TPZ FENCING MAINTENANCE THROUGHOUT CONSTRUCTION.6.EMPLOY A PROFESSIONAL ARBORIST FOR REGULAR TREE MAINTENANCE TASKS.7.SHIELD TREE ROOTS FROM RUNOFF DURING MATERIAL PLACEMENT. MINIMIZE TRENCHING INTREE AREAS.8.PREVENT PONDING, ERODING, OR EXCESSIVE WETTING IN TPZ DURING WATERINGOPERATIONS.9.NO CONSTRUCTION MATERIALS WITHIN TPZ; AVOID SOIL COMPACTION OVER ROOTS.10.KEEP TPZ FREE OF WEEDS AND TRASH.11.MULCH TPZ WITH 4" ORGANIC LAYER, AVOIDING PROXIMITY TO THE TREE TRUNK.12.NO EXCAVATION WITHIN TPZ WITHOUT APPROVAL. HAND PRUNE ROOTS 1' OUTSIDE REQUIREDEXCAVATION LIMIT.13.PROTECT ROOTS DURING EXCAVATION; PROVIDE TEMPORARY SUPPORT UNTILPERMANENTLY COVERED.GENERAL NOTES:1.CAUTION! CALL THE TOLL-FREE NUMBER 800-892-0123 BEFORE EXCAVATION.2.DIMENSIONS PROVIDED IN WRITING TAKE PRECEDENCE OVER SCALED DIMENSIONS. REPORTANY DISCREPANCIES TO THE LANDSCAPE ARCHITECT.3.THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING UNDERGROUND UTILITIES, PIPES, ANDSTRUCTURES. IMMEDIATE REPAIR OF ANY DAMAGE TO UTILITIES IS THE CONTRACTOR'SRESPONSIBILITY. THE LANDSCAPE ARCHITECT IS NOT LIABLE FOR ITEMS NOT SHOWN ONPLANS.4.THE INDICATED LOCATIONS OF EXISTING UTILITIES ARE APPROXIMATE; OTHER UTILITIES MAYEXIST. EXERCISE CAUTION.5.PROPOSED AND FINISHED GRADES ARE BASED ON OWNER-PROVIDED INFORMATION. REPORTANY FIELD MEASUREMENT DISCREPANCIES TO THE LANDSCAPE ARCHITECT PROMPTLY.6.BEFORE HARDSCAPE CONSTRUCTION, SURVEY AND STAKE OUT PIERS, FOOTINGS, ANDWALLS FOR LANDSCAPE ARCHITECT REVIEW. THE CONTRACTOR ASSUMES RESPONSIBILITYFOR CORRECTIONS DUE TO LAYOUT ERRORS.7.QUANTITIES PER DRAWINGS AND SPECIFICATIONS ARE THE CONTRACTOR'S RESPONSIBILITY.LANDSCAPE ARCHITECT-PROVIDED QUANTITIES ARE FOR CONVENIENCE; CONTRACTORSSHOULD BID THEIR VERIFIED QUANTITIES.8.REFER TO CIVIL ENGINEER'S DRAWINGS FOR ADDITIONAL INFORMATION ON EASEMENTS,SETBACKS, AND UNDERGROUND UTILITIES.9.BLOUNT DESIGNS IS NOT RESPONSIBLE FOR DAMAGES RESULTING FROM PLAN CHANGESWITHOUT WRITTEN CONSENT.PROPERTY LINEEASEMENTS & SETBACKSCENTERLINESITE LEGENDEXPANSION JOINTEJEJEJCONTROL JOINTCJCJCJDECORATIVE SCORINGLANDSCAPE EDGINGCLALIGNALIGNALIGNFLOODLINEMATERIAL CALL OUTDETAIL CALL OUTX-#X/0#DETAILSHEET #CATEGORY MATERIAL #ENLARGEMENT REFERENCEACENTERLINEALIGNALIGNALIGNALIGNALIGNCLCLX##SECTION/ELEVATION REFERENCEPLAN LEGENDTREE TO REMAINDEMO & TREE PROTECTION LEGENDTREE PROTECTION FENCINGTREE PROTECTIONTREE PROTECTIONTREE TO BE REMOVEDTREE #XTREE #HARDSCAPE DEMOLANDSCAPE DEMODRAINAGE NOTES:1.DRAINLINES-ALL DRAIN LINE PIPES SHOULD BE PVC ASTM D3034 SDR 35, UNLESS SPECIFIED OTHERWISE.USE SANITARY TEES, SWEEP ELBOWS, OR 45-DEGREE WYE FITTINGS FOR TEE CONNECTIONSWHENEVER POSSIBLE. ENSURE A SMOOTH CONTINUOUS FALL WITH A MINIMUM DRAINAGESLOPE OF ONE (1%) PERCENT.2.FRENCH DRAINS-FOR FRENCH DRAINS, USE 4" PERFORATED PVC SDR 35, 2-HOLE PIPE, UNLESS OTHERWISENOTED. EXCAVATE DRAINAGE TRENCH TO ACCOMMODATE A MINIMUM OF ONE CUBIC FOOTOF WASHED CRUSHED STONE AGGREGATE (ASTM #57). SEPARATE AGGREGATE FROMSUBGRADE SOIL WITH FILTER FABRIC LINING THROUGHOUT THE TRENCH. OVERLAP FILTERFABRIC MATERIAL A MINIMUM OF 12" AT THE TOP OF THE TRENCH. CONNECT DRAIN LINESUSING SANITARY TEES, SWEEP ELBOWS, OR 45-DEGREE WYE FITTINGS. AVOID THE USE OFCORRUGATED DRAIN PIPES. ENSURE A MINIMUM DRAINAGE SLOPE OF ONE (1%) PERCENTWITH A SMOOTH CONTINUOUS FALL.3.SLEEVING-CONTRACTOR MUST NOTE AND INSTALL SLEEVES AT LOCATIONS AS SHOWN ON THEDRAINAGE PLAN. BLOUNT DESIGNS SHOULD BE NOTIFIED TO REVIEW SLEEVE LOCATIONSBEFORE CONCRETE POUR. ALL SLEEVES SHOULD BE 24" DEEP, PVC SCHEDULE 40, AND 4" INDIAMETER UNLESS OTHERWISE SPECIFIED.4.WATERPROOFING-BEHIND ALL RETAINING WALLS, THE CONTRACTOR MUST INSTALL BITUTHENE 3000BELOW-GRADE WATERPROOFING MEMBRANE WITH HYDRODUCT 220 GEOCOMPOSITE DRAINLAYER. INSTALLATION SHOULD COMPLY WITH THE MANUFACTURER'S SPECIFICATIONS.5.SKIMMER COVERS-AT EACH POOL SKIMMER LOCATION, THE CONTRACTOR MUST INCLUDE AND INSTALLHIDE-A-LID SKIMMER LIDS APPROVED BY THE LANDSCAPE ARCHITECT.6.SLOPE-ALL PLANTED AREAS SHOULD DRAIN AT A MINIMUM OF TWO (2%) PERCENT IN THE DIRECTIONOF CATCH BASINS AND AWAY FROM THE HOUSE. NO STANDING WATER OR PONDING ISALLOWED.7.LOCATION-ALL DRAINAGE DEVICES MUST BE LOCATED AND SPECIFIED AS SHOWN ON THE PLAN. THECONTRACTOR SHALL NOT RELOCATE OR SUBSTITUTE DEVICES WITHOUT PRIORAUTHORIZATION FROM BLOUNT DESIGNS.IRRIGATION NOTES:1.THE IRRIGATION SYSTEM MUST BE DESIGNED BY A LICENSED IRRIGATOR AND APPROVED BYTHE APPROPRIATE GOVERNING AGENCY BEFORE ANY WORK IS PERFORMED.2.PERMITS AND FEES SHOULD BE INCLUDED IN THE ESTIMATE.3.SEPARATE THE IRRIGATION SYSTEM FROM THE POTABLE WATER SYSTEM WITH ANAPPROVED DOUBLE-CHECK ASSEMBLY INSTALLED IN A JUMBO METER BOX WITH A BLACK LID.THE METER SIDE OF THE DOUBLE-CHECK SHALL BE CONNECTED WITH COPPER.4.ZONE THE SYSTEM WITH SHADY AREAS SEPARATE FROM SUNNY AREAS AND BEDSSEPARATED FROM THE LAWN.5.ALL NEW TREES SHOULD HAVE AT LEAST TWO ADJUSTABLE BUBBLE HEADS, AND THEYSHOULD BE ZONED SEPARATELY.6.POTS SHOULD BE ZONED SEPARATELY.7.USE CL200 OR BETTER FOR ALL PIPING, EXCEPT FOR 1/2", WHICH WILL BE CL315.8.POP-UP LAWN AND BED HEADS SHOULD BE RAINBIRD 1800 SERIES EQUIPMENT WITH AWEATHERMATIC B SERIES NOZZLE.9.ALL SOLENOID VALVES SHOULD BE RAINBIRD PEB SERIES OR BETTER.10.SHRUB RISERS SHOULD BE 1/2" TYPE M COPPER EQUIPPED WITH A WEATHERMATIC #92SHRUB ADAPTER AND A #100 SERIES NOZZLE.11.THE CONTROLLER SHOULD BE A RAINBIRD ESP SERIES OR BETTER.12.ALL FIELD WIRING SHOULD BE 14UF RED FOR ALL HOT WIRES AND 14UF WHITE FOR THECOMMON.13.VALVE BOXES SHOULD HAVE BLACK LIDS.14.TRENCHING WITHIN THE DRIP LINE OF ANY EXISTING TREE OR SHRUB SHOULD BE DONE BYHAND TO MINIMIZE ROOT DISTURBANCE. TUNNEL UNDER ANY TREE ROOT 2" DIAMETER ORGREATER.15.ALL WORK SHOULD BE GUARANTEED FOR ONE YEAR FROM THE DATE OF ACCEPTANCE. ANYNECESSARY ADJUSTMENTS WITHIN THE ONE-YEAR WARRANTY PERIOD SHOULD BECOMPLETED AT NO ADDITIONAL COST TO THE OWNER.16.AFTER COMPLETION AND ACCEPTANCE OF THE INSTALLATION, PROVIDE THE OWNER WITHCOMPLETE AS-BUILT DRAWINGS SHOWING THE LOCATION OF ALL SPRINKLER HEADS, VALVES,AND PIPING TO SCALE.17.INSTRUCT THE OWNER IN THE PROPER OPERATION OF THE IRRIGATION SYSTEM.18.THE CONTRACTOR SHOULD BE THOROUGHLY COVERED BY PUBLIC LIABILITY AND PROPERTYDAMAGE INSURANCE.BED PREP, PLANTING, SOD NOTES:BED PREP1.REGULAR MIX: USE THIS MIX FOR ALL NEW BEDS, EXCEPT THOSE LISTED IN THE AZALEASECTION BELOW. EXCAVATE SOIL AS NECESSARY, ADD A 6" LAYER OF MIX SOIL CONSISTINGOF 70% COMPOST AND 30% EXPANDED SHALE. TILL TO A DEPTH OF 6 INCHES, RESULTING IN AFINAL PRODUCT OF A 50/50 BLEND OF MIX SOIL AND NATIVE SOIL.2.ACIDIC MIX: USE THIS MIX FOR AZALEAS, CAMELLIAS, JAPANESE MAPLES, LOROPETALUMS,HYDRANGEAS, AND OTHER ACID-LOVING PLANTS. EXCAVATE SOIL AS NECESSARY. EACHPLANT INDICATED ABOVE SHOULD HAVE A MINIMUM OF 9 SQ. FT. BY 15" DEPTH OF PRE-MIXEDAZALEA MIX. MOUND SOIL UP TO 6" MAX, IF POSSIBLE, TO AID IN DRAINAGE.3.MULCH: AFTER PLANTING OPERATIONS ARE COMPLETE, TOP DRESS ALL BEDS, EXCEPTAZALEAS AND ASIAN JASMINE, WITH A 2" LAYER OF SHREDDED HARDWOOD MULCH. KEEPMULCH OFF PLANT TRUNKS A MINIMUM OF 2".IMPORTANT NOTE1.ALL BEDS SHOULD SLOPE AWAY FROM THE HOUSE A MINIMUM OF 2% FOR 10 FT MINIMUM ORTO THE CLOSEST DRAIN. MIX SOILS AVAILABLE AT SOIL BUILDING SYSTEMS OR LIVING EARTHTECHNOLOGIES. ANY OTHER VENDORS MUST BE APPROVED BY THE LANDSCAPE ARCHITECT.2.QUANTITIES LISTED ARE FOR BUDGETING PURPOSES ONLY. THE CONTRACTOR SHOULDEXECUTE THEIR TAKEOFF TO ENSURE THE FINAL PLANT COUNTS ARE CORRECT. USE PLANTSPACING INDICATED TO DETERMINE GROUNDCOVER QUANTITIES.3.THE OWNER, CLIENT, AND LANDSCAPE ARCHITECT RESERVE THE RIGHT TO REJECT ANYUNHEALTHY OR INFERIOR PLANT MATERIAL AT ANY TIME.RENDERS ARE FOR CONCEPTUAL PURPOSES ONLYREFERENCE PLANS FOR BIDDING OR CONSTRUCTION PURPOSESDETAILS ARE FOR CONCEPTUAL PURPOSES ONLY.CONTRACTOR OR ENGINEER TO VERIFY.PROJECT NUMBER:ISSUE DATE: SHEET SIZE: 24" x 36"2404905.17.2024PRELIMINARY SET (NOT FOR CONSTRUCTION)SHEET TITLESHEET NO.CENTRAL PARK AT BLACKBERRY FARM 1011 BLACKBERRY DRIVE, COPPELL, TX234 561123456ABCDEFABCDEF214.970.7565support@blountdesigns.com5600 Tennyson Pkwy, Suite 335Plano, Texas 75024 MHX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX X X X X X XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX2'-0"2'-0" 1'-8"4" 6" 4" MIN.GRADE TO DRAINFINISH GRADE4'x2'x2' LEUDERSLIMESTONE BLOCKSAWN ON 4 SIDESDECOMPOSEDGRANITECOMPACTEDGRAVEL BASEFILTER FABRICEDGINGSODL2.01SITE PLANScale: 1" = 20'-0"SITE PLANAPROJECT NUMBER:ISSUE DATE: SHEET SIZE: 24" x 36"2404905.17.2024PRELIMINARY SET (NOT FOR CONSTRUCTION)SHEET TITLESHEET NO.CENTRAL PARK AT BLACKBERRY FARM 1011 BLACKBERRY DRIVE, COPPELL, TX234 561123456ABCDEFABCDEF214.970.7565support@blountdesigns.com5600 Tennyson Pkwy, Suite 335Plano, Texas 750248' HT. COLUMN6' HT. COLUMN4' HT. COLUMNEXISTING WOOD FENCEEXISTING IRON FENCEPROPOSED WOOD FENCEPROPOSED IRON FENCEGATE MOTOREX-IRONEX-IRONEX-WOODEX-WOODXXXXXFENCE LEGENDPROPERTY LINEEASEMENTS & SETBACKSCENTERLINESITE LEGENDEXPANSION JOINTEJEJEJCONTROL JOINTCJCJCJDECORATIVE SCORINGLANDSCAPE EDGINGCLALIGNALIGNALIGNFLOODLINEScale: 1" = 1'-0"LIMESTONE BLOCK - SECTIONBBL2.01EXISTING 5'-0" SIDEWALKEXISTING 5'-0" SIDEWALKEXISTING 5'-0"SIDEWALKLANDSCAPE BERMLANDSCAPE BERMLANDSCAPE BERMDECOMPOSED GRANITE(2) 4'x2'x2' LEUDERS LIMESTONEBLOCK SAWN ON 4 SIDESDECOMPOSED GRANITESODSODSODCANOPY TREE4' MULCH RING W/ V-CUT EDGE (TYP)CANOPY TREE4' MULCH RING W/ V-CUT EDGE (TYP)DRAINAGE INLET (TYP)IRON FENCEIRON FENCEIRON FENCE5'- 0 "5'-0"5'-0"5'-0"5'- 0 "STORM DRAIN INLETPER CIVILPLANT BED ONLANDSCAPE BERMPLANT BED (TYP)21" RCP5'-0" CONCRETE WALK5'-0" CONCRETE WALK5'-0" CONCRETE WALKBOLLARD W/ LIGHT (TYP)ELECTRIC SLEEVE (TYP) MHX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX X X X X X XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX5'-0"6'-5"1 5 ' - 0 "7'-0"10'-0"3 0 ' - 0 "5'-0"10'-0" 5'-0"13'-0"15'-0"42'-0"15'-0"7'-0"23'-5"20'-0"26'-4"2 2 ' - 1 1 " 6 0 ' - 4 " 43' - 0 " 22'-0"24'-0"10'-0"10' -0"9'-3"9'-0"4'-4"4'-8"30'-0"1 5 ' - 0 "1'-6"4'-4"30'-0"15'-8"L2.01ADIMENSIONALCONTROL PLANScale: 1" = 20'-0"DIMENSIONAL CONTROL PLANAPROJECT NUMBER:ISSUE DATE: SHEET SIZE: 24" x 36"2404905.17.2024PRELIMINARY SET (NOT FOR CONSTRUCTION)SHEET TITLESHEET NO.CENTRAL PARK AT BLACKBERRY FARM 1011 BLACKBERRY DRIVE, COPPELL, TX234 561123456ABCDEFABCDEF214.970.7565support@blountdesigns.com5600 Tennyson Pkwy, Suite 335Plano, Texas 750248' HT. COLUMN6' HT. COLUMN4' HT. COLUMNEXISTING WOOD FENCEEXISTING IRON FENCEPROPOSED WOOD FENCEPROPOSED IRON FENCEGATE MOTOREX-IRONEX-IRONEX-WOODEX-WOODXXXXXFENCE LEGENDPROPERTY LINEEASEMENTS & SETBACKSCENTERLINESITE LEGENDEXPANSION JOINTEJEJEJCONTROL JOINTCJCJCJDECORATIVE SCORINGLANDSCAPE EDGINGCLALIGNALIGNALIGNFLOODLINEDRAINAGE LEGENDDRAINAGE SLEEVE4" DRAIN LINE6" DRAIN LINE8" DRAIN LINE12" DRAIN LINE4" PERFORATED DRAIN LINE6" PERFORATED DRAIN LINEFRENCH DRAINFRENCH DRAINDOWNSPOUTAREA DRAINCHANNEL DRAINSUMP PUMPPOP-UPDRAIN VENTCURB CASTINGT-DRAIN12"18"24"21" RCPSTORM DRAIN INLETPER CIVIL MHX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX X X X X X XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXL3.01GRADING & DRAINAGEPLANScale: 1" = 20'-0"GRADING & DRAINAGE PLANAEXISTING ELEVATIONPROPOSED ELEVATIONFLOW DIRECTION00"00GRADING LEGENDEXISTING MINOR TOPO.EXISTING MAJOR TOPO.PROPOSED MINOR TOPO.PROPOSED MAJOR TOPO.SWALESWALESWALEPROJECT NUMBER:ISSUE DATE: SHEET SIZE: 24" x 36"2404905.17.2024PRELIMINARY SET (NOT FOR CONSTRUCTION)SHEET TITLESHEET NO.CENTRAL PARK AT BLACKBERRY FARM 1011 BLACKBERRY DRIVE, COPPELL, TX234 561123456ABCDEFABCDEF214.970.7565support@blountdesigns.com5600 Tennyson Pkwy, Suite 335Plano, Texas 7502449.9'53.0'49.8'49.0'49.2'50.2'49.5'FL:444.0'49.5'48.9'50.0'48.3'50.1'50.8'50.1'51.4'50.7'50.3'51.4'50.6'50.0'49.8'50.0'53.0'50.8'50.0'50.6'50.4'49.8'50.8'51.2'51.3'51.0'51.0'50.5'51.1'50.9'50.7'50.2'49.0'50.2'47.0'DRAINAGE LEGENDDRAINAGE SLEEVE4" DRAIN LINE6" DRAIN LINE8" DRAIN LINE12" DRAIN LINE4" PERFORATED DRAIN LINE6" PERFORATED DRAIN LINEFRENCH DRAINFRENCH DRAINDOWNSPOUTAREA DRAINCHANNEL DRAINSUMP PUMPPOP-UPDRAIN VENTCURB CASTINGT-DRAIN12"18"24"EXISTING 5'-0" SIDEWALKEXISTING 5'-0" SIDEWALKEXISTING 5'-0"SIDEWALKSTORM DRAIN INLETPER CIVIL21" RCP5'-0" CONCRETE WALK5'-0" CONCRETE WALK5'-0" CONCRETE WALKLANDSCAPE BERMLANDSCAPE BERMLANDSCAPE BERM6" PVC TO CONNECT TOEXISTING STORM DRAIN CURBINLET (BEYOND)6" PVC TO CONNECT TOEXISTING STORM DRAIN CURBINLET (BEYOND)ELECTRIC SLEEVE (TYP) MHX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX X X X X X XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXL7.01PLANTING PLANScale: 1" = 20'-0"PLANTING PLANAPROJECT NUMBER:ISSUE DATE: SHEET SIZE: 24" x 36"2404905.17.2024PRELIMINARY SET (NOT FOR CONSTRUCTION)SHEET TITLESHEET NO.CENTRAL PARK AT BLACKBERRY FARM 1011 BLACKBERRY DRIVE, COPPELL, TX234 561123456ABCDEFABCDEF214.970.7565support@blountdesigns.com5600 Tennyson Pkwy, Suite 335Plano, Texas 75024PLANT SCHEDULECANOPY TREESORNAMENTAL TREESSHRUBSGRASSESGROUND COVERSYMB.QTY.COMMON NAME / Botanical NameSIZESPACING4LIVE OAK / Quercus virginiana4" CAL.PER PLAN2SHUMARD RED OAK / Quercus shumardii4" CAL.PER PLAN2MAGNOLIA / Magnolia grandiflora4" CAL.PER PLAN1PERSIMMON OAK / Diospyros texana4" CAL.PER PLAN2EASTERN RED CEDAR / Juniperus virginiana3" CAL.PER PLAN1BUR OAK / Quercus macrocarpa4" CAL.PER PLAN3LACEBARK ELM / Ulmus parvifolia4" CAL.PER PLAN3VITEX / Vitex agnus-castus2" CAL.PER PLAN3ELDARICA (AFGAN) PINE / Pirus eldarica2" CAL.PER PLAN13CRIMSON BARBERRY / Berberis thunbergii 'Crimson Pygmy'3 GAL.30" O.C.78PETITE PILLAR DWARF BOXWOOD / Buxus sempervirens 'Monalex'3 GAL.24" O.C.10TEXAS SAGE GREEN CLOUD /7 GAL.30" O.C.19PINK PAMPAS GRASS / Cortaderia selbana 'Rosea'15 GAL.60" O.C.88REGAL MIST PINK MUHLY / Muhlenbergia capillaris 'Lenca'5 GAL.36" O.C.64MEXICAN FEATHER GRASS / Nassella tenuissima1 GAL.24" O.C.37,805 SFSODN/AN/A258 SFDECOMPOSED GRANITEN/AN/A(14) BOLLARD W/ LIGHT (TYP)CHRISTMAS LIGHTS IN MAGNOLIAS