Loading...
Monitoring Well 205 N Denton Tap RdCONTACT CITY OF COPPELL ROW INSPECTOR AVERY DAVIS (469-858-2006, adavis@coppelltx.gov) AT LEAST 48 HOURS PRIOR TO ANY CONSTRUCTION ACTIVITY 03/28/2025Scott Latta X Existing MW Proposed MW Place the proposed monitoring well in the 5' wide area of the ROW and sidewalk and utility easement that is between back of curb and the sidewalk Actual approximate location of 16" water line N Denton Tap Rd.Speed Limit Posted: 40 MPH 320 ft240 ft240 ft240 ft RIGHT LANECLOSED RIGHT LANECLOSED ROADWORKAHEADENDROAD WORKMatch Line AMatch Line AMergingTaper LegendPortable Sign StandArrow BoardDate: 3/19/2025Author: J. PerteeTTCP: 19815Notes:-Sign spacing may be adjusted to fit field conditions.-Buffer space may be eliminated or modified to fit field conditions.-Roads with no posted speed limit have been designed for 30 mph.-Road Work Ahead signs shall be placed on all cross streetsintersecting within the advance signing. T he signs should be placeda minimum of 100 feet in advance of the intersection. Project: Sun-Belt Industrial Services-240 N Denton Tap Rd-Coppell T XComments:All signs & devices shall be placed in accordance with the latest provisions of the TexasDepartment of Transportation (T xDOT )-Traffic Operations Division Standard Drawingswith respect to any applicable provisions from the city of Coppell.Access to residential and commercial driveway s to be maintained at all times.Parking ban shall be coordinated with the City of Coppell Police Department. 1(800)-343-2650www.awpsafety.com Sheet 1 of 2PLANS ARENOT T O SCALEN-Channelizing Device Spacing:-Taper - 40 ft C-C- Tangent - 80 ft C-C N Denton Tap Rd.Speed Limit Posted: 40 MPHKingsbridge DrSpeed Limit Posted: 25 MPHTown Center DrSpeed Limit Not PostedTown Center DrSpeed Limit Not Posted450 ft320 ft BufferSpace 240 ft ENDROAD WORKROADWORKAHEAD100 ftROADWORKAHEAD120 ftROADWORKAHEAD 120 ft ROADWORKAHEADMatch Line AMatch Line ASIDEWALKCLOSEDSIDEWALKCLOSEDRIGHT LANEMUSTTURN RIGHTMergingTaper LegendPortable Sign StandProposed WellWork AreaTubularADA Pedestrian Barricade Date: 3/19/2025Author: J. PerteeTTCP: 19815Notes:-Sign spacing may be adjusted to fit field conditions.-Buffer space may be eliminated or modified to fit field conditions.-Roads with no posted speed limit have been designed for 30 mph.-Road Work Ahead signs shall be placed on all cross streetsintersecting within the advance signing. T he signs should be placeda minimum of 100 feet in advance of the intersection. Project: Sun-Belt Industrial Services-240 N Denton Tap Rd-Coppell T XComments:All signs & devices shall be placed in accordance with the latest provisions of the TexasDepartment of Transportation (T xDOT )-Traffic Operations Division Standard Drawingswith respect to any applicable provisions from the city of Coppell.Access to residential and commercial driveway s to be maintained at all times.Parking ban shall be coordinated with the City of Coppell Police Department. 1(800)-343-2650www.awpsafety.com Sheet 2 of 2PLANS ARENOT T O SCALEN-Channelizing Device Spacing:-Taper - 40 ft C-C- Tangent - 80 ft C-C