Loading...
ST22-01 Royal Lane-PT250908 70413- 5349632 LWVL S – RELO CABLES S ROYAL LN – RDMV DESIGNER: CAROL JONES 214.288.6730 70413- 5349632 LWVL S – RELO CABLES S ROYAL LN – RDMV DESIGNER: CAROL JONES 214.288.6730 WORK LOCATION EX DUCT BANK FRONTIER PROPOSED: ADJUST MH TO FINAL GRADE X X FRONTIER PROPOSED: CONSTRUCTION TO VERIFY DEPTH OF DUCT BANK. SECTION OF SS TO BE REPLACED & EX WL TO BE LOWERED AT CITY 1+35 AND NEW LAT AT CITY 3+25. IF IN CONFLICT, WILL REVISE TO REPLACE. LAT A2 – SEE PROFILE BELOW. X X X X XFRONTIER PROPOSED: 2" HDPE E/W 432 FIBER SEE PROFILE BELOW FRONTIER PROPOSED: 2" HDPE E/W 50C COPPER XXX EX DUCT BANK X X CAUTION: EXIST FIBER & COPPERXXMH 677MH676 STORM LINE A 70443- 5349632 LWVL S – RELOC S ROYAL LN COPPELL - RDMV DESIGNER: CAROL JONES 214.288.6730 70443- 5349632 LWVL S – RELOC S ROYAL LN COPPELL - RDMV DESIGNER: CAROL JONES 214.288.6730 Work Safely SHEET 1 OF 16 X BORE/NEW PLACEMENT NEW HANDHOLE EXIST HANDHOLE REMOVE HANDHOLE EXIST FIBER & COPPER EXIST COPPER REMOVE FIBER HDPE FOR FIBER DROP REMOVE DOWNGUY REMOVE PEDESTAL LEGEND XX X X X X X BORE/NEW PLACEMENT NEW HANDHOLE EXIST HANDHOLE REMOVE HANDHOLE EXIST FIBER & COPPER EXIST COPPER REMOVE FIBER HDPE FOR FIBER DROP REMOVE DOWNGUY REMOVE PEDESTAL LEGEND X X X X X FRONTIER PROPOSED: 2" HDPE E/W 432 FIBER & 50C COPPER GENERAL NOTES: * CONTACT 811 TEXAS FOR UTILITY LOCATES 48 HOURS PRIOR TO CONSTRUCTION START. * NEW HDPE TO BE AT 48" DEPTH, UNLESS SPECIFIED DIFFERENT FOR OTHER UTILITES AS SHOWN IN PROFILES. * EXISTING FIBER & COPPER CABLES TO BE PULLED FROM EXISTING CONDUIT. EXISTING PEDESTALS ARE TO BE REMOVED AS SHOWN. * EXISTING MH & HH TO BE PLACED TO FINAL GRADE. * CONTRACTOR IS REQUIRED TO HAVE APPROVED PERMIT AT JOB SITE AT ALL TIMES. CAUTION: EXIST FIBER & COPPER MH677A WATER NOT BEING PLACED PER CITY FRONTIER PROPOSED: 2" HDPE E/W 432 FIBER2' MIN2' MINFRONTIER PROPOSED: PLC 2X3 HH 5'5'45'45'18'18' FRONTIER PROPOSED: CLEAR TRAFFIC CONTROL BASE 18'18' MH678 FTR 3X5 FRONTIER PROPOSED: RELOC NECK & LID. ADJUST MH TO FINAL GRADE X X X X X X EX DUCT BANK CAUTION: EXIST FIBER & COPPER 70443- 5349632 LWVL S – RELOC S ROYAL LN COPPELL - RDMV DESIGNER: CAROL JONES 214.288.6730 70443- 5349632 LWVL S – RELOC S ROYAL LN COPPELL - RDMV DESIGNER: CAROL JONES 214.288.6730 Work Safely SHEET 2 OF 16 FRONTIER PROPOSED: HAND DIG TO ADJUST 3X5 TO FINAL GRADE FRONTIER PROPOSED: 2" HDPE E/W 50C COPPER 7'7'45'45'7'7'SEE SHEET 1SEE SHEET 1SHEET 3SHEET 3 XX XX EX DUCT BANK X EX 4-DUCT BANK X X RMV 2X3 X XXXX X X CAUTION: EXIST FIBER & COPPER WATER NOT BEING PLACED PER CITY FRONTIER PROPOSED: 2" HDPE E/W 50C COPPER FRONTIER PROPOSED: 2" HDPE E/W 50C COPPER FRONTIER PROPOSED: CONSTRUCTION TO VERIFY DEPTH OF DUCT BANK & NEW LAT AT CITY 11+95. IF IN CONFLICT, WILL REVISE TO REPLACE. LAT A6 - SEE CITY PROFILE BELOW. EX DUCT BANK Work Safely 7'7'45'45'7'7' 70443- 5349632 LWVL S – RELOC S ROYAL LN COPPELL - RDMV DESIGNER: CAROL JONES 214.288.6730 70443- 5349632 LWVL S – RELOC S ROYAL LN COPPELL - RDMV DESIGNER: CAROL JONES 214.288.6730 SHEET 3 OF 16SEE SHEET 2SEE SHEET 2SHEET 4SHEET 4 MH679 FRONTIER PROPOSED: 2" HDPE E/W 50C COPPER FRONTIER PROPOSED: ADJUST 3X5 TO FINAL GRADE. CAUTION: EXIST FIBER & COPPER RM PED X X 70443- 5349632 LWVL S – RELOC S ROYAL LN COPPELL - RDMV DESIGNER: CAROL JONES 214.288.6730 70443- 5349632 LWVL S – RELOC S ROYAL LN COPPELL - RDMV DESIGNER: CAROL JONES 214.288.6730 Work Safely SHEET 4 OF 16 FRONTIER PROPOSED: LOCATE & VERIFY FIBER & COPPER IF IN CONFLICT OF NEW INLET BOXES BEING PLACED. ONLY REPLACE IF CITY CAN NOT WORK AROUND. IF REQUIRED, 2" HDPE E/W FIBER &/OR COPPER. FRONTIER PROPOSED: RELOCATE LID AND NECK 2'. ADJUST TO FINAL GRADE. 45' MSz FTR 3X5 X X X 1111 NORTHPOINT DR1110 NORTHPOINT DRFTR 3X5 X X X X X X X X X X X X X X FRONTIER PROPOSED: LOCATE & VERIFY LOC & DEPTH OF FIBERS. NEW INLET BOX BEING PLACED AROUND CITY STA 14+00. ONLY REPLACE IF CITY WILL NOT WORK AROUND.. IF NEEDED, REVISION WILL BE MADE TO PLC 2" HDPE E/W FIBER &/OR COPPER. X CAUTION: EXIST FIBER & COPPER 70443- 5349632 LWVL S – RELOC S ROYAL LN COPPELL - RDMV DESIGNER: CAROL JONES 214.288.6730 70443- 5349632 LWVL S – RELOC S ROYAL LN COPPELL - RDMV DESIGNER: CAROL JONES 214.288.6730 Work Safely SHEET 5 OF 16 FTR 3X5 FTR 3X5 FRONTIER PROPOSED: PLC 2" HDPE E/W 50C COPPER. LOCATE & VERIFY LOCATION OF FIBERS CROSSING S. ROYAL LN. ONLY REPLACE IF NECESSARY, IN CONJUNCTION WITH NEW CULVERT BOX FINDINGS. FTR 3X5 FRONTIER PROPOSED: LOCATE & VERIFY FIBER & COPPER IF IN CONFLICT OF NEW INLET BOXES BEING PLACED. ONLY REPLACE IF CITY CAN NOT WORK AROUND. IF REQUIRED, 2" HDPE E/W FIBER &/OR COPPER. BORE PROFILE SEE SHEET 5A DETAIL PLAN & BORE PROFILE SEE SHEET 5B 10" SS FRONTIER PROPOSED: 2" HDPE ONLY IF NECESSARY 17' FRONTIER PROPOSED: 2" HDPE ONLY IF NECESSARY 17' UNKNOWN DEPTH 2' MIN MUST MAINTAIN A MINIMUM OF 2 FT SEPARTATION! 70443- 5349632 LWVL S – RELOC S ROYAL LN COPPELL - RDMV DESIGNER: CAROL JONES 214.288.6730 70443- 5349632 LWVL S – RELOC S ROYAL LN COPPELL - RDMV DESIGNER: CAROL JONES 214.288.6730 Work Safely SHEET 5A OF 16 PLAN ON SEE SHEET 5 2'2'8'8'6'6'31'31' 12" W EX 3X5 EX 3X5 FRONTIER PROPOSED: 2" HDPE ONLY IF NECESSARY 12" W UNK DEPTH POTHOLE WATER & VERIFY DEPTH PRIOR TO DIGGING! MUST MAINTAIN A MINIMUM OF 2 FT SEPARTATION! APPROX 4FT 7' 12" W EX 3X5 EX 3X5 FRONTIER PROPOSED: 2" HDPE ONLY IF NECESSARY 12" W UNK DEPTH POTHOLE WATER & VERIFY DEPTH PRIOR TO DIGGING! MUST MAINTAIN A MINIMUM OF 2 FT SEPARTATION! APPROX 4FT 7' 70443- 5349632 LWVL S – RELOC S ROYAL LN COPPELL - RDMV DESIGNER: CAROL JONES 214.288.6730 70443- 5349632 LWVL S – RELOC S ROYAL LN COPPELL - RDMV DESIGNER: CAROL JONES 214.288.6730 Work Safely SHEET 5B OF 16 2' MIN OVERALL PLAN ON SEE SHEET 5 FRONTIER PROPOSED: 2" HDPE E/W 96 FIBER IF NECESSARY MATCH LINEMATCH LINEMATCH LINEMATCH LINE CAUTION: EXIST FIBER & COPPER RMV GEN TEL MKR 445 S ROYAL LN 1111 NOTHPOINTFRONTIER PROPOSED: ADJUST 3X5 TO FINAL GRADE 70443- 5349632 LWVL S – RELOC S ROYAL LN COPPELL - RDMV DESIGNER: CAROL JONES 214.288.6730 70443- 5349632 LWVL S – RELOC S ROYAL LN COPPELL - RDMV DESIGNER: CAROL JONES 214.288.6730 Work Safely SHEET 6 OF 16 CAUTION: EXIST FIBER & COPPER 444 S ROYAL LN XXXXXX FRONTIER PROPOSED: 2" HDPE E/W 48 FIBER 445 S ROYAL LN 70443- 5349632 LWVL S – RELOC S ROYAL LN COPPELL - RDMV DESIGNER: CAROL JONES 214.288.6730 70443- 5349632 LWVL S – RELOC S ROYAL LN COPPELL - RDMV DESIGNER: CAROL JONES 214.288.6730 Work Safely SHEET 7 OF 16 EX FIBER & COPPER SHEET 8SHEET 8