Gigabit-PT251203Install conduit in DART ROW to connect existing Gigabit facilities.
12/02/2025
SWL
CONTACT CITY OF COPPELL ROW INSPECTOR TYLER BOYER (469-978-0818,
tboyer@coppelltx.gov) PRIOR TO ANY CONSTRUCTION ACTIVITY
Depth of 8" SS field
measured at approximately
14 ft deep at this SSMH
FREEPORT PKWY FREEPORT PK
W
Y
1+00
2+00
2+80
0+00 102°
102°
0027.9
0
32.9494278
-97.0107834
DART RAIL LINE35'4'40'35'65'DRIVEWAYDRIVEWAY39'31'B
U
R
I
E
D
F
I
B
E
R
C
A
U
T
I
O
N
A
C
T
I
V
E
G
I
G
A
B
I
T
O
P
T
I
C
C
A
B
L
E
BURI
E
D
FI
B
E
R
CAU
TI
O
N
ACTI
V
E
GI
G
A
BI
T
OPTI
C
C
A
B
L
E
STA. 0+00 TO STA. 2+80
DIR.BORE (280') 1-86" HDPE
CASING E/W 2-1.25" HDPE
864ct FIBER OPTIC CABLE
STA. 0+00
PROP. 4X4 BORE PIT
LAT: 32.915608
LONG: -97.126431
STA. 2+80
PROP. 4X4 BORE PIT
LAT: 32.915608
LONG: -97.126431148'66'120'XXXX
XXXXXXXXX4'4'100'
100'DART RAIL LINE14
SCALE
EXCEPT AS MAY BE OTHERWISE PROVIDED BY
CONTRACT, THESE DRAWINGS AND SPECIFICATIONS
S H A L L R E M A I N T H E P R O P E R T Y O F M C I
COMMUNICATIONS SERVICES INC. BOTH BEING
ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE
REPRODUCED, COPIED, OR USED FOR ANY
PURPOSE WITHOUT SPECIFIC WRITTEN PERMISSION.TITLE: FIBER OPTIC CABLE ROUTEOUTSIDE PLANT CONSTRUCTIONINNERCITY FIBERNET, LLCDBAGIGABIT FIBERDATE:
ENGINEER:
CHECKED BY:
HORIZONTAL:
VERTICAL:
SHEET OF
FILE:GIGABIT FIBER - COPPELLREVISIONS
DATE DESCRIPTION BYNo.
COBBFENDLEY
CP
10/17/2024
DRAWN BY:
N/A
COPPELL ,TX
COPPELL, TX15
CITY OF COPPELL
PROJECT:P2024-01-FTW2
COPPELL_FTW to Ring 2- 125,803
CITY OF COPPELL
CONFIDENTIAL
FOR PROPRIETARY USE ONLY
EXCEPT AS MAY BE OTHERWISE
PROVIDED THIS DRAWING SHALL
REMAIN THE PROPERTY OF
GIGABIT FIBER
AND SHALL NOT BE REPRODUCED,
COPIED OR USED FOR ANY PURPOSE
WITHOUT SPECIFIC WRITTEN
PERMISSION.
SM
1:50
DALLAS COUNTY
COPPELL, TX
SEE PROFILE ON
SHEET 15
CALL BEFORE YOU DIG
HOURS NOTICE REQUIRED
1-800-245-4545
48
NOTE:
UNDERGROUND UTILITIES HAVE BEEN PLOTTED FROM AVAILABLE
RECORDS AND FIELD OBSERVATIONS BUT ARE NOT NECESSARILY EXACT.
IT IS THE CONTRACTOR RESPONSIBILITY TO FIELD LOCATE ALL
UNDERGROUND OBSTRUCTIONS AND UTILITIES PRIOR TO CONSTRUCTION.
COMPLETE REPAIR OF ANY AND ALL DAMAGES INCURRED SHALL BE AT
THE EXPENSE OF THE CONTRACTOR.
CAUTION !!!!
CONTRACTOR TO LOCATE &
VERIFY ALL EXISTING UTILITIES
PRIOR TO CONSTRUCTION
CAUTION!!!
EXIST. BURIED FIBER, TELEPHONE, CATV, GAS, ELECTRIC, WATER,
SANITARY SEWER & STORM SEWER FACILITIES IN CONSTRUCTION AREA
AND HAVE NOT BEEN FIELD LOCATED, CONTRACTOR TO VERIFY EXACT
LOCATION AND DEPTH PRIOR TO ANY DIGGING AND/OR BORING.
NOTE:
CONTRACTOR TO VERIFY
EXISTING GIGABIT TIE-IN POINT
PRIOR CONSTRUCTION.
Know what's below.
before you dig.Call
RNOTE:
RIGHT OF WAY LINES WERE ESTABLISHED BY RESEARCH OF PUBLIC INFORMATION.
NO BOUNDARY SURVEY OR PROPERTY LINE SURVEY WAS ESTABLISHED BY
COBB FENDLEY & ASSOCIATES. RIGHT OF WAY BOUNDARY MUST BE FIELD VERIFIED
BY A REGISTERED PROFESSIONAL LAND SURVEYOR TO ACCURATELY VERIFY
RIGHT OF WAY AND PROPERTY LINES PRIOR TO CONSTRUCTION.
NOTE:
•CALL LOCATES 48HRS IN ADVANCE. HAVE ALL UTILITIES MARKED. CONTACT APPROPRIATE RR
AUTHORITIES.
•SET UP THE NECESSARY TRAFFIC CONTROL, FLAGGERS, AND PERSONAL PROTECTION FOR THE WORKERS.
•REVIEW THE PLANS ONSITE AND FOLLOW THROUGHOUT THE JOB.
•PREPARE MACHINERY AND MATERIALS
•POTHOLE ALL UTILITIES VIA HYDRO-EXCAVATION
•FINAL WALK THRU WITH INSPECTOR
•START CONSTRUCTION. HORIZONTAL DIRECTIONAL BORE.
•PULL THROUGH CASING. PULL THROUGH DUCT.
•CLEAN AND MAKE SAFE CONSTRUCTION SITE AND REPAIR THE AREA.
STA. 0+00 TO STA. 2+80
DIR. BORE (280')
1-6" HDPE CASING
TWO (2) 1.25" HDPE SDR 11
ONE (1) 1.86" 4-WAY
E/W 864ct FIBER OPTIC CABLE
W/10GA TRACER WIRE
EXHIBIT A14
EXHIBIT A-14
City of Coppell 8"
sanitary sewer
Depth of 8" SS field
measured at approximately
14 ft deep at this SSMH
0+00 2+001+00
SCALE
HOR: 1" = 50
PROFILE
WEST SIDE OF FREEPORT PKWY
LOOKING EAST
VER: 1" = 10'
520
530
510
3+00
540
PROP. 4'X4'
BORE PIT
PROP. 4'X4'
BORE PIT
DIR. BORE (280') 1-86" 4-WAY
E/W 2-1-25" HDPE SDR 11BEG. DIR. BORESTA 0+00BEG. 1-86" 4-WAYEND. DIR. BORESTA 2+80END. 1-86" 4-WAY864ct FIBER OPTIC CABLE20'DEPTH520
530
510
540
500 5008' SEPARATION7' SEPARATION7' SEPARATION15
SCALE
EXCEPT AS MAY BE OTHERWISE PROVIDED BY
CONTRACT, THESE DRAWINGS AND SPECIFICATIONS
S H A L L R E M A I N T H E P R O P E R T Y O F M C I
COMMUNICATIONS SERVICES INC. BOTH BEING
ISSUED IN STRICT CONFIDENCE AND SHALL NOT BE
REPRODUCED, COPIED, OR USED FOR ANY
PURPOSE WITHOUT SPECIFIC WRITTEN PERMISSION.TITLE: FIBER OPTIC CABLE ROUTEOUTSIDE PLANT CONSTRUCTIONINNERCITY FIBERNET, LLCDBAGIGABIT FIBERDATE:
ENGINEER:
CHECKED BY:
HORIZONTAL:
VERTICAL:
SHEET OF
FILE:GIGABIT FIBER - COPPELLREVISIONS
DATE DESCRIPTION BYNo.
COBBFENDLEY
CP
10/17/2024
DRAWN BY:
N/A
COPPELL ,TX
COPPELL, TX15
CITY OF COPPELL
PROJECT:P2024-01-FTW2
COPPELL_FTW to Ring 2- 125,803
CITY OF COPPELL
CONFIDENTIAL
FOR PROPRIETARY USE ONLY
EXCEPT AS MAY BE OTHERWISE
PROVIDED THIS DRAWING SHALL
REMAIN THE PROPERTY OF
GIGABIT FIBER
AND SHALL NOT BE REPRODUCED,
COPIED OR USED FOR ANY PURPOSE
WITHOUT SPECIFIC WRITTEN
PERMISSION.
SM
1:50
DALLAS COUNTY
COPPELL, TX
CALL BEFORE YOU DIG
HOURS NOTICE REQUIRED
1-800-245-4545
48
Know what's below.
before you dig.Call
R
NOTE:
UNDERGROUND UTILITIES HAVE BEEN PLOTTED FROM AVAILABLE
RECORDS AND FIELD OBSERVATIONS BUT ARE NOT NECESSARILY EXACT.
IT IS THE CONTRACTOR RESPONSIBILITY TO FIELD LOCATE ALL
UNDERGROUND OBSTRUCTIONS AND UTILITIES PRIOR TO CONSTRUCTION.
COMPLETE REPAIR OF ANY AND ALL DAMAGES INCURRED SHALL BE AT
THE EXPENSE OF THE CONTRACTOR.
CAUTION!!!
EXIST. BURIED FIBER, TELEPHONE, CATV, GAS, ELECTRIC, WATER,
SANITARY SEWER & STORM SEWER FACILITIES IN CONSTRUCTION AREA
AND HAVE NOT BEEN FIELD LOCATED, CONTRACTOR TO VERIFY EXACT
LOCATION AND DEPTH PRIOR TO ANY DIGGING AND/OR BORING.
NOTE:
RIGHT OF WAY LINES WERE ESTABLISHED BY RESEARCH OF PUBLIC INFORMATION.
NO BOUNDARY SURVEY OR PROPERTY LINE SURVEY WAS ESTABLISHED BY
COBB FENDLEY & ASSOCIATES. RIGHT OF WAY BOUNDARY MUST BE FIELD VERIFIED
BY A REGISTERED PROFESSIONAL LAND SURVEYOR TO ACCURATELY VERIFY
RIGHT OF WA Y AND PROPERTY LINES PRIOR TO CONSTRUCTION.
STA. 0+00 TO STA. 2+80
DIR. BORE (280')
1-6" HDPE CASING
TWO (2) 1.25" HDPE SDR 11
ONE (1) 1.86" 4-WAY
E/W 864ct FIBER OPTIC CABLE
W/10GA TRACER WIRE END. DIR. BOREEND. 1-4" HDPE CASING1-6"BEG. DIR. BOREBEG. 1-4" HDPE CASING1-6"EXHIBIT A-15
Updated Depth to 20' to avoid Water at 14.5', SS at 15' and Lumen line at 18'
Depth of 8" SS field
measured at approximately
15 ft deep.