St Andrews Manor-LR011227 (2)Hooper Engineering Laboratories, Inc. C ' n Materials Testing REPORTO~ JOB NO.: 01.1076 CLIENT: ~ne~olmes ~ullaers, Inc. ~' DATE: 27 December 2001 /'/ -- ,~" ,%. ---~,~ LOCATION ~;z: SAMPLE DATA: SET I SET 2 MIX NO. 982 Truck No. 278 Cement 361 Type I Ticket No, 52620 Flyash 64 Time Batched 3:30pm Sand 1541 Time Sampled 4:45pm in. Concrete Temp. (ASTM C1064~ 63°F 1.0 in. 1850 Air Content (ASTM C231) Water 270 Unit Weight (ASTM C138) Admix #1 None Admix #2 AEA COMPRESSIVE STRENGTH TESTS (ASTM C39) (Standard 6 inch x 12 inch c¥1inder) Cylinder Slump Age Test Total Load Compressive Required Number Inches Days Date Pounds Stren.gth 28-Day (ASTM C143) p S~ama~ Strength 1 5.50 ~7 ) 01/03/02 73,600 2 5.50 ~ 01/03/02 71,700 3 5.50 01/24/02 4 5.50 28 01/24/02 28-Day Average 3000 TECHNICIAN: DISTRIBUTION: MFM (1) The Holmes Builders, Inc. (1) City of Coppell 2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148