St Andrews Manor-LR011228 (3)Hooper Engineering Laboratories, Inc.
Construction Materials Testing
REPORT OF CONCRETE TESTS
CLIENT: The Holmes Builders, Inc.
PROJECT: St. Andrews Manor
748 DeForest, Coppell, TX
LOCATION OF POUR SET 1:
LOCATION OF POUR SET 2:
JOB NO.: 01.1076
DATE: 28 December 2001
SUPPLIER: Redi-Mix
Belled piers: #1, 2, 10, 11, 12, 17, 19, 20, 27 and 28
SAMPLE DATA: SET 1
Truck No. 275
Ticket No. 150687
Time Batched 11:20am
Time Sampled 12:53pm
Concrete Temp. (ASTM C1064) 60°F
Air Content (ASTM C231)
Unit Weight (ASTM C138)
SET 2
MIX NO. 982
Cement 361 Type I
Flyash 64
Sand 1541
1.0 in. 1850
Water 270
Admix #1 None
Admix #2
AEA
COMPRESSIVE STRENGTH TESTS (ASTM C39)
(Standard 6 inch x 12 inch cylinder)
Cylinder Slump Age Test Total Load Compressive Required
Number Inches Days Date Pounds Strength 28-Day
(ASTM C143~ psi Strength
5 5.50 7 01 ~04/02
6 5.50 7 01 ~04~02
7 5.50 28 01/25/02
8 5.50 28 01/25/02
66,000 2330
66,600 2360
98,400 5480
90,800 3210
28-Day Average 3350
3OOO
TECHNICIAN:
DISTRIBUTION:
MFM
(1) The Holmes Builders, Inc.
(1) City of Coppell
2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148