CF-Coppell Rd SC-LR020118Hooper Engineering Laboratories, Inc.
Construction Materials Testing
REPORT OF CONCRETE TESTS JOB NO.:
CLIENT: Texas Unified Constructors, Inc. DATE:
PROJECT: Field Service Offices & Maint. Fac., Coppell SUPPLIER:
LOCATION OF POUR SET 1: Grade beam, Bldg. 2, line B & D
between 6 and 10
LOCATION OF POUR SET 2:
01.1054
18 January 2002
Lattimore
SAMPLE DATA: SET 1
Truck No. 1040
Ticket No. 7112772
Time Batched 1:30pm
Time Sampled 2:15pm
Concrete Temp. IASTM C1064) 58°F
Air Content IASTM C231)
Unit Weight (ASTM C138)
SET 2 MIX NO. 54
Cement
Flyash
Sand
ir].
1.0 in.
Water
Admix //1
Admix //2
AEA
COiVIPRESS/VE STRENGTH TESTS (ASTM C39)
(Standard 6 inch x 12 inch cylinder)
Cylinder Slump Age Test Total Load Compressive Required
Number Inches Days Date Pounds Strength 2B-Day
IASTM C143} psi Strength
99 3.25 7 01/25/02
100 3.25 28 02/15/02
101 3.25 28 02/15/02
95,700
28-Day Average
3390
3000
TECHNICIAN:
DISTRIBUTION:
CBC (2:00pm~3:30pm)
(3) City of Coppell
(1) Vidaud & Associates
(1) Doyle Engineering Group
(1) Texas Unified Constructors, Inc,
2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148
Hooper Engineering Laboratories, Inc.
Construction Materials Testing
REINFORCING STEEL PLACEMENT INSPECTION
CLIENT: Texas Unified Constructors, Inc. DATE: 18 January 2002
PROJECT: Field Service Offices & Maintenance Facility JOB NO. 01.1054
Coppell, TX
TIME: 1.5 hours
AREA INSPECTED:
DATE OF INSPECTION:
DEFICIENCIES NOTED:
Grade beam, Bldg. 2, line 10; line B & D between
lines 6 & 10
1/18/02 (12:30pm-2:00pm)
CORRECTIONS
NUMBER LOCATION/ITEM DESCRIPTION OBSERVED
1 Clean off tops of pier caps. Yes
TECHNICIAN:
DISTRIBUTION:
CBC
(3) City of Coppell
(1) Vidaud & Associates
(1) Doyle Engineering Group
(1) Texas Unified Constructors, Inc.