CF-Coppell Rd SC-LR020117Hooper Engineering Laboratories, Inc.
Construction Materials Testing
PROJECT: Field Service Offices & Maint. Fac., Coppell
LOCATION OF POUR SET 1: Grade beam, line 3 & 5 @ Bldg. 2
LOCATION OF POUR SET 2:
JOB NO.: 01.1054
DATE: 17 January 2002
SUPPLIER: Lattimore
SAMPLE DATA: SET 1 SET 2 MIX NO.
Truck No. 1106 Cement
Ticket No. 3139504 Flyash
Time Batched 12:30pm Sand
Time Sampled 1:30pm in.
Concrete Temp. (ASTM C10641 60°F 1.0 in.
Air Content (ASTM C231) Water
Unit Weight (ASTM C138) Admix //1
Admix //2
AEA
54
COMPRESSIVE STRENGTH TESTS (ASTM C39)
(Standard 6 inch x 12 inch cylinder)
Cylinder Slump Age Test
Number inches Days Date
(ASTM C143)
96 3.75 0~~7 J 1/24/02
97 3.75~02/I 4/02
98 3.75 02/14/02
Total Load Compressive Required
Pounds Strength 28-Day
psi Strength
106,400 ~
28-Day Average 3000
TECHNICIAN:
DISTRIBUTION:
CBC (1:00pm-2:30pm)
(3) City of Coppell
(1) Vidaud & Associates
(1) Doyle Engineering Group
(1) Texas Unified Constructors, Inc.
2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148
Hooper Engineering Laboratories, Inc.
Construction Materials Testing
REINFORCING STEEL PLACEMENT INSPECTION
CLIENT: Texas Unified Constructors, Inc.
DATE: 17 January 2002
PROJECT:
Field Service Offices & Maintenance Facility
Coppeil, TX
JOB NO. 01.1054
TIME: 1.0 hour
AREA INSPECTED: Grade beam, Bldg. 2, lines 3, 5 and 6
DATE OF INSPECTION: 1/17/02 (12:00 Noon-1:00pm)
DEFICIENCIES NOTED:
NUMBER
LOCATION/ITEM DESCRIPTION
CORRECTIONS
OBSERVED
None
REMARKS:
All items reviewed were present and placed according to project plans and
specifications, at time of final inspection.
TECHNICIAN:
DISTRIBUTION:
CBC
(3) City of Coppell
(1) Vidaud & Associates
(1) Doyle Engineering Group
(1) Texas Unified Constructors, Inc.
2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148