Loading...
CF-Coppell Rd SC-LR020116Hooper Engineering Laboratories, Inc. Construction Materials Testing .... DATE: 16 January 2002 PROJECT: Field Service Offices & Maint. Fac., Coppell SUPPLIER: Lattimore LOCATION OF POUR SET 1: Grade beams at utility storage building, on line B from 1 to 5 and on line 3 from B to B.3 LOCATION OF POUR SET 2: SAMPLE DATA: SET 1 Truck No. 01125 Ticket No. 7112663 Time Batched 9:04am Time Sampled 9:40am Concrete Temp. {ASTM C1064) 57°F Air Content (ASTM C231) Unit Weight (ASTM C138) SET 2 MIX NO. 54 Cement Flyash Sand in, 1.0 in. Water Admix #1 Admix #2 AEA COMPRESSIVE STRENGTH TESTS (ASTM C39) (Standard 6 inch x 12 inch cylinder) Cylinder Slump Age Test Total Load Compressive Required Number Inches Days Date Pounds Stren.gth 28-Day (ASTM C143) psi Strength 93 4.50 ~ 01/23/02 105,600 94 4.50 02/13/02 95 4.50 28 02/13/02 28-Day Average 3000 TECHNICIAN: DISTRIBUTION: MFM (9:00am-11:00am) (3) City of Coppell (1) Vidaud & Associates (1) Doyle Engineering Group (1) Texas Unified Constructors, Inc. 2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148