ST0001-LR020121 (2)Ro gineers
Client:
Project:
City of Coppell
Atto: Ms. Sttsan Taylor - Engineering Dept
PO Box 478
Coppell TX 75109 ~. ~ 0//~
Creekview Drive and
Freeport Parkway
Coppell, TX
Perform In-Place Density Test in accordance with ASTM Standards.
PROJECT DATA
8908 Ambassador Row
Dallas, Texas 7524%4510
(214) 630-9745
(214) 630-9819 (fax)
IN-PLACE DENSITY TESTING
Report No.: 015729 141507
Project No.:
Date of Service: 01/10/2002
Report Date: 01/21/2002
Lqrr'_.0
CONTRACTOR: Infrastructure Services, Inc.
Gauge: Troxler 3430 Moisture
Test Methods: ASTM D-2922
ASTM D-3017 Gauge Serial No: 32685 Current: 640
Test Mode: DT Previous: 674
MOISTURE DENSITY RELATIONS
Maximum
M/D No. Description Moisture % Density pcf
Standard Counts
Density
Current: 3014
Previous: 3095
Project Requirements
Moisture Density
I Dark Brown, Gray and Tan Clay 2,5..~ ,s f . 9~.~1 ,~Optiml~m +5t 95 min
TEST
NO
PROBE M/D MOISTURE WET DENSITY DRYDENSITY DENSITY
TEST LOCATION DEPTH No. (%) (pc0 (pcl~ (% max)
Waterline/Backfill
1 Creekview, Station 6+00, 2' below grade 6" 1 21.7' 100.3 82.4 87 *
Waterline/Backfill
2 Creekview, Station 6+00, final 6" 1 22.7* 1 10.9 90.4 96
Waterline/Backfill
3 Creekview, Station 9+00, 2' below grade 6" 1 27.4 113.9 89.4 95
Waterline/Backfill
4 Creekview, Station 9+00, final 6" 1 29.9 120.7 92.9 98
Waterline/Backfill
5 Creekview, Station 12+00, 2' below grade 6" I 25.6 112.9 89.9 95
Waterline/Backfill
6 Creekview, Station 12+00, final 6" 1 20.4* 97.3 80.8 86 *
An asterisk (*) appears next to test results which do NOT meet the project specifications.
Started: 10:30a Finished: 12:30p
(1) City of Copp¢ll
(I) Schrickel, Rogins & Assoc.. Inc.
Technician: Joe Jernigan
Report Distribution:
(I) City of Coppell
(I) City of Coppell
(1) City of Coppe[l
(1) lnfi-astmcture Services, Inc.
C Stark
Project Manager
LiMiTATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject mailer provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they arc addressed and shall not be reproduced except in full without thc written approval of Roue Engineers, Inc.
07DK Page 1 of I