ST0001-LR020121 (2)Ro gineers Client: Project: City of Coppell Atto: Ms. Sttsan Taylor - Engineering Dept PO Box 478 Coppell TX 75109 ~. ~ 0//~ Creekview Drive and Freeport Parkway Coppell, TX Perform In-Place Density Test in accordance with ASTM Standards. PROJECT DATA 8908 Ambassador Row Dallas, Texas 7524%4510 (214) 630-9745 (214) 630-9819 (fax) IN-PLACE DENSITY TESTING Report No.: 015729 141507 Project No.: Date of Service: 01/10/2002 Report Date: 01/21/2002 Lqrr'_.0 CONTRACTOR: Infrastructure Services, Inc. Gauge: Troxler 3430 Moisture Test Methods: ASTM D-2922 ASTM D-3017 Gauge Serial No: 32685 Current: 640 Test Mode: DT Previous: 674 MOISTURE DENSITY RELATIONS Maximum M/D No. Description Moisture % Density pcf Standard Counts Density Current: 3014 Previous: 3095 Project Requirements Moisture Density I Dark Brown, Gray and Tan Clay 2,5..~ ,s f . 9~.~1 ,~Optiml~m +5t 95 min TEST NO PROBE M/D MOISTURE WET DENSITY DRYDENSITY DENSITY TEST LOCATION DEPTH No. (%) (pc0 (pcl~ (% max) Waterline/Backfill 1 Creekview, Station 6+00, 2' below grade 6" 1 21.7' 100.3 82.4 87 * Waterline/Backfill 2 Creekview, Station 6+00, final 6" 1 22.7* 1 10.9 90.4 96 Waterline/Backfill 3 Creekview, Station 9+00, 2' below grade 6" 1 27.4 113.9 89.4 95 Waterline/Backfill 4 Creekview, Station 9+00, final 6" 1 29.9 120.7 92.9 98 Waterline/Backfill 5 Creekview, Station 12+00, 2' below grade 6" I 25.6 112.9 89.9 95 Waterline/Backfill 6 Creekview, Station 12+00, final 6" 1 20.4* 97.3 80.8 86 * An asterisk (*) appears next to test results which do NOT meet the project specifications. Started: 10:30a Finished: 12:30p (1) City of Copp¢ll (I) Schrickel, Rogins & Assoc.. Inc. Technician: Joe Jernigan Report Distribution: (I) City of Coppell (I) City of Coppell (1) City of Coppe[l (1) lnfi-astmcture Services, Inc. C Stark Project Manager LiMiTATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject mailer provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they arc addressed and shall not be reproduced except in full without thc written approval of Roue Engineers, Inc. 07DK Page 1 of I