Amberpoint BP-LR020206 (2)WATER INJECTION OBSERVATION
Date of Service:
Client No.:
Client:
Location:
Procedure:
02/06/02
3181
Transwestem Commercial Services
5001 Spring Valley Rd., Suite 600W
Dallas, Texas 75244
Building Pad
Report No.:
Project No.:
Project:
General Contractor:
Injector:
94021029.0040
94021029
Amberpoint Building No. 1
Amberpoint Bus. Pk @ Coppell
Coppell, Texas
Hill & Wilkinson
Jowell
On this date, a representative of HBC Engineering, Inc. observed the injection of water at this
site. During the injection process, the following observations were recorded.
4th No. of Probes:
Pass No.: __._._._._._._.____.-
4 Probe Length: 10 feet
SPECIFICATION
Surfactant added io each load.
~at manifold. ~
.__~_ection downward in 18 inch intervals. ~--
~ection was 10 feet. ~--
~tion was 5 feet maximum. ~
~usal at each location.
OBSERVATION________---
Yes No N/A
.____.____----
X ____________---
X ________.---
X __.______-----
X ______.-----
X _____----
Comments:
Technician: S. Long
U~ Engineering, Inc.
Report Distribution:
(l) Transwestera Commercial Setwiccs
(1) O'Briea & Associates, lac.
(1) TcctmiSb*uctares, Inc.
(1) Cit7 of Coppell - Cons~r. Insp.
(1) City of Coppell - Bldg. Insp.
(1) Hill & Wilkinson, Ltd.
(1) Halff Associa~s
(1) State Farm Insurance
Eugene Harbour
Principal
9911w
This report is exclusively for the use of the client indicated above and shall not be reproduced in full without written approval o~ HBC Engineer
® ®
WATER INJECTION OBSERVATION
ENGIi~EF-RING, INC.
Date of Service:
Client No.:
Client:
Location:
Procedure:
02/06/02
3181
Transwestern Commercial Services
5001 Spring Valley Rd., Suite 600W
Dallas, Texas 75244
Report No.:
Project No.:
Project:
94021029.0039
94021029
Ambe[point Building No. 1
Amberpoint Bus. Pk @ Coppell
Coppell, Texas
Building Pad #2
General Contractor: Hill & Wilkinson
Injector: Jowell
On this date, a representative of I-IBC Engineering, Inc. observed the injection of water at this
site. During the injection process, the following observations were recorded.
Pass No.: 4th No. of Probes: 4 Probe Length: 12 feet
OBSERVATION
SPECIFICATION Yes No N/A
Surfactant added to each load. X
Injection pressure 50 to 200 psi at manifold. X
Injection downward in 18 inch intervals. X
Total depth of injection was 10 feet. X
Spacing of injection was 5 feet maximum. X
~iection to refusal at each location. X
Comments:
Technician: S. Campbell
Report Distribution:
(1) Transwestern Commercial Services
(1) O'Btien & Associates, Inc.
(1) TechniStructures, Inc.
(1) City of Coppell - Constx. Insp.
9911w
(1) City of Coppell - Bldg. Insp.
(1) Hill & Wilkinson, Ltd.
( 1 ) Halff Asscciates
(1) State Farm Insurance
Engineering, Inc.
Eugene Harbour
Principal
This report is exclusively for ti'~ use of the client indicated above and shall not be reproduced in full without written approval of HBC Engineer
i I ®