Amberpoint BP-LR020206 (2)WATER INJECTION OBSERVATION Date of Service: Client No.: Client: Location: Procedure: 02/06/02 3181 Transwestem Commercial Services 5001 Spring Valley Rd., Suite 600W Dallas, Texas 75244 Building Pad Report No.: Project No.: Project: General Contractor: Injector: 94021029.0040 94021029 Amberpoint Building No. 1 Amberpoint Bus. Pk @ Coppell Coppell, Texas Hill & Wilkinson Jowell On this date, a representative of HBC Engineering, Inc. observed the injection of water at this site. During the injection process, the following observations were recorded. 4th No. of Probes: Pass No.: __._._._._._._.____.- 4 Probe Length: 10 feet SPECIFICATION Surfactant added io each load. ~at manifold. ~ .__~_ection downward in 18 inch intervals. ~-- ~ection was 10 feet. ~-- ~tion was 5 feet maximum. ~ ~usal at each location. OBSERVATION________--- Yes No N/A .____.____---- X ____________--- X ________.--- X __.______----- X ______.----- X _____---- Comments: Technician: S. Long U~ Engineering, Inc. Report Distribution: (l) Transwestera Commercial Setwiccs (1) O'Briea & Associates, lac. (1) TcctmiSb*uctares, Inc. (1) Cit7 of Coppell - Cons~r. Insp. (1) City of Coppell - Bldg. Insp. (1) Hill & Wilkinson, Ltd. (1) Halff Associa~s (1) State Farm Insurance Eugene Harbour Principal 9911w This report is exclusively for the use of the client indicated above and shall not be reproduced in full without written approval o~ HBC Engineer ® ® WATER INJECTION OBSERVATION ENGIi~EF-RING, INC. Date of Service: Client No.: Client: Location: Procedure: 02/06/02 3181 Transwestern Commercial Services 5001 Spring Valley Rd., Suite 600W Dallas, Texas 75244 Report No.: Project No.: Project: 94021029.0039 94021029 Ambe[point Building No. 1 Amberpoint Bus. Pk @ Coppell Coppell, Texas Building Pad #2 General Contractor: Hill & Wilkinson Injector: Jowell On this date, a representative of I-IBC Engineering, Inc. observed the injection of water at this site. During the injection process, the following observations were recorded. Pass No.: 4th No. of Probes: 4 Probe Length: 12 feet OBSERVATION SPECIFICATION Yes No N/A Surfactant added to each load. X Injection pressure 50 to 200 psi at manifold. X Injection downward in 18 inch intervals. X Total depth of injection was 10 feet. X Spacing of injection was 5 feet maximum. X ~iection to refusal at each location. X Comments: Technician: S. Campbell Report Distribution: (1) Transwestern Commercial Services (1) O'Btien & Associates, Inc. (1) TechniStructures, Inc. (1) City of Coppell - Constx. Insp. 9911w (1) City of Coppell - Bldg. Insp. (1) Hill & Wilkinson, Ltd. ( 1 ) Halff Asscciates (1) State Farm Insurance Engineering, Inc. Eugene Harbour Principal This report is exclusively for ti'~ use of the client indicated above and shall not be reproduced in full without written approval of HBC Engineer i I ®