Amberpoint BP-LR020205WATER INJECTION OBSERVATION
Date of Service:
Client No.:
Client:
Location:
O2/05/O2
3181
Transwestern Commercial Services
5001 Spring Valley Rd., Suite 600W
Dallas, Texas 75244
Report No.:
Project No.:
Project:
Building Pad #2
General Contractor:
Injector:
94021029.0037
94021029
Amberpoint Building No. 1
Amberpoint Bus. Pk @ Coppell
Coppell, Texas
Hill & Wilkinson
Jowell
Procedure:
On this date, a representative of ItBC Engineering, Inc. observed the injection of water at this
site. During the injection process, the following observations were recorded.
Pass No.: 4th No. of Probes: 4 Probe Length: 12 feet
OBSERVATION
SPECIFICATION Yes No N/A
Surfactant added to each load. X
Injection pressure 50 to 200 psi at manifold. X
Injection downward in 18 inch intervals. X
Total depth of injection was 10 feet. X
Spacing of injection was 5 feet maximum. X
In, iection to refusal at each location. X
Comments:
Technician: S. Campbell
Report Distribution:
( 1 ) Transwestern Commercial Services
(1) O'Brien & Associates, Inc.
( 1 ) TechniStructures, Inc.
(1) City of Coppell - Constr. Insp.
(1) City of Coppell - Bldg. Insp.
(1) Hal & Willdnson, Ltd.
( 1 ) Halff Associates
(1) State Farm Insurance
I--I]C Engineering, Inc.
Eugene Harbour
Principal
9911w This report is exclusively for the use of the client indicated above and shall not be reproduced in full without written approval of HBC Engineer
WATER INJECTION OBSERVATION
Date of Service:
Client No.:
Client:
O2/05/02
3181
Transwestem Commercial Services
5001 Spring Valley Rd., Suite 600W
Dallas, Texas 75244
Report No.:
Project No.:
Project:
94021029.0036
94021029
Amberpoint Building No. 1
Amberpoint Bus. Pk ~ Coppell
Coppell, Texas
Location:
Building Pad, lines L to Q and
9.2to 11
General Contractor: Hill & Wilkinson
Injector: .lowell
Procedure:
On this date, a representative of HBC Engineering, Inc. observed the injection of water at this
site. During the injection process, the following observations were recorded.
Pass No.: 3rd No. of Probes: 4 Probe Length: 10 feet
OBSERVATION
SPECIFICATION Yes No N/A
Surfactant added to each load. X
Injection pressure 50 to 200 psi at manifold. X
Injection downward in 18 inch intervals. X
Total depth of injection was 10 feet. X
Spacing of injection was 5 feet maximum. X
Injection to refusal at each location. X
Commen~:
Technician: S. Long
Re~o~t Distribution:
(1) Transwestern Commercial Services
(1) O'Brien & Associates, Inc.
( ! ) TeelmiStructures, Inc.
( 1 ) City of Copl~ll - Constr. Imp.
(1) City of Copp¢ll - Bldg. Insp.
(I) Hill & Wilkinson, Ltd.
(1) Haiti' gssociat~
(1) State Farm Insurance
I-~ Engineering, Inc.
Eugene Harbour
Principal
This report is exclus~vety for the use of the client imlicated above and shall not be reproduced in full without written approval of HBC Engineer