Loading...
YMCA-LR020115 GEOTECHNICAL AND ENVIRONMENTAL CONSULTANTS CONCRETE CYLINDER TEST REPORT Coppell YMCA 146 Town Center Boulevard Coppell, Texas REPORTED TO: YMCA of Metropolitan Dallas 601 Akard Street Dallas, Texas 75201 ATTN: Mr. Todd Baker REPORT NO. 32 REG PROJECT NO. 8524 SAMPLE DATE: 01-16-02 TECHNICIAN: M. Banchetti CONTRACTOR: Hill & Wilkinson Location of Sample Set Number J Location J Quantity Represented 1 Pier Cap: E.9-1 3/3 Design Information Source of Concrete J Mix Identification J Specified Strength p.s.i. LMC 38 3000 Test Results Set Cylinder Age @ Total Load Compressive No. ID Date Tested Test lbs. Strength p.s.i. I 6558 01-23-02 7 90500 3200 6558 02-13-02 28 6558 02-13-02 28 6558 Hold H Average Strength p.s.i. Cylinder Data Set J Cylinder Time of Concrete Air Ticket No. ID Slump Sample Air Temp. Temp. Entrainment Number 5558 4.25 1:30PM 65 64 4.75 7112679 Mail Distribution: (1) YMCA of Metropolitan Dallas/ Mr. Todd Baker (1) YMCA of Metropolitan Dallas/ Mr. Curt Hazelbaker (1) City of Coppell/Mr. Kenneth Griffen (1) Good Fulton & Farrell/ Mr. Scott Wegener (1) Hill & Wilkinson/Mr. Lanny Huggins (1) Dowdey Anderson & Associates/ Mr. Bill Anderson Submitted by: REED ENGINEERING GROUP, INC. Original Signed By Keith Atkins KEAJje 2424 STUTZDR · SUIT£400 · DALLAS, TX 75235 · T~L [214] 3~05600 · ~AX [214] 350 0019 GEOTECHNICAL AND ENVIRONPIENTAL CONSULTANTS CONCRETE CYLINDER TEST REPORT Coppell YMCA 146 Town Center Boulevard Coppell, Texas REPORTED TO: YMCA of Metropolitan Dallas 601 Akard Street Dallas, Texas 75201 ATTN: Mr. Todd Baker CONTRACTOR: Hill & Wilkinson Location of Sample Set Number I Location REPORT NO. 30 REG PROJECT NO. 8524 SAMPLE DATE: 01-15-02 TECHNICIAN: R. Bullion Quantity Represented Grade beams line E.3 from 1.6 to 1.9, line 1.6 10/10 from E.3 to F and line D.3 from 1 to 1.9 Design Information lS°urce °f C°ncrete ILMC Mix Identification 38 J Specified Strength P's'i' 1 3000 Test Results Set Cylinder Age @ Total Load Compressive Average No. ID Date Tested Test lbs. Strength p.s.i. Strength p.s.i. 1 6538 01-22-02 7 103040 3650 6538 02-12-02 28 117240 4150 6538 02-12-02 28 125220 4430 6538 Hold H 429O Cylinder Data Set I Cylinder Time of Concrete Air Ticket lNo. ID Slump Sample Air Temp. Temp. Entrainment Number 6538 3.50 3:40PM 57 66 N/A 07-111323 Mail Distribution: (1) YMCAof Metropolitan Dallas/ Mr. Todd Baker (1) YMCA of Metropolitan Dallas/ Mr. Curt Hazelbaker (1) City of Coppell/Mr. Kenneth Griffen (1) Good Fulton & Farrell/ Mr. Scott Wegener (1) Hill & Wilkinson/Mr. Lanny Huggins (1) Dowdey Anderson & Associates/ Mr. Bill Anderson Submitted by: REED ENGINEERING GROUP, INC. original Signed By Keith Atkins KEA/je 2424 STUTZ DR. · SUITE400 · DALLAS, TX75235 · TEL [214] SS0 5600 * ~x [2141350 0019