YMCA-LR020104FR I~ E /-'1 I
GEOTECHNICAL AND G F=~ r-I L.J ~
ENVIF, ONPIENTAL CONSULTANTS
CONCRETE CYLINDER TEST REPORT
Coppell YMCA
146 Town Center Boulevard
Coppell, Texas
REPORTED TO: YMCA of Metropolitan Dallas
601 Akard Street
Dallas, Texas 75201
A'i-FN: Mr. Todd Baker
REPORT NO. 20
REG PROJECT NO. 8524
SAMPLE DATE: 01-07-02
TECHNICIAN: R. Bullion
CONTRACTOR: Hill & Wilkinson -~
Location of Sample
Set Number I Location I Quantity Represented
1 Piers: E.3-1.6 and E-1.6 7/15
Design Information
Source of Concrete J Mix Identification J Specified Strength p.s.i.
LMC 49 3000
Test Results
Set Cylinder Age @ Total Load Compressive Average
No. ID Date Tested Test lbs. Strength p.s.i. Strength p.s.i.
1 6168 01-14-02 7 103120 3650
6168 02-04-02 28
6168 02-04-02 28
6168 Hold H
Cylinder Data
Set Cylinder Time of
N1o. iD Slump Sample Air Temp.
6168 4.50 12:05PM 48
Concrete Air Ticket
Temp. Entrainment Number
61 N/A 07-111285
Mail
Distribution: (1) YMCA of Metropolitan Dallas/
Mr. Todd Baker
(1) YMCA of Metropolitan Dallas/
Mr. Curt Hazetbaker
(1) City of Coppell/Mr. Kenneth Griffen
(1) Good Fulton & Farrell/
Mr. Scott Wegener
(1) Hill & Wilkinson/Mr. Lanny Huggins
(1) Dowdey Anderson & Associates/
Mr. Bill Anderson
Submitted by:
REED ENGINEERING GROUP, INC.
Original Signed By
Keith Atkins
KEA/je
2424 STUTZ DR. · SUITE400 · DALLAS, TX75235 · TELl214]3505600 · FAX[214]3500019
GEOTECHNICAL AND J~ F~J t"l U F~j
ENVIRONMENTAL CONSULTANTS
CONCRETE CYLINDER TEST REPORT
Coppell YMCA
146 Town Center Boulevard
Coppell, Texas
REPORTED TO: YMCA of Metropolitan Dallas
601 Akard Street
Dallas, Texas 75201
ATTN: Mr. Todd Baker
REPORT NO. 19
REG PROJECT NO. 8524
SAMPLE DATE: 01-04-02
_TECHNICIAN: R. Bullion
CONTRACTOR: Hill & Wilkinson
Location of Sample
Set Number I Location I Quantity Represented
1 Pier: G-1.8 4/14
Design Information
Source of Concrete I Mix Identification I Specified Streih~h p.s./.
LMC 49 3000
Test Results
Set Cylinder Age @ Total Load
No. ID Date Tested Test lbs.
1 6078 01-11-02 7 79480
6078 02-01-02 28 129630
6078 02-01-02 28 130980
6078 Hold H
Compressive Average
Strength p.s./. Strength p.s./.
2810
4590
464O 4620
Cylinder Data
Set Cylinder Time of Concrete Air Ticket
N . ID Slump Sample Air Temp. Temp. Entrainment Number
~ 6078 5.00 12:00PM 38 61 N/A 06-740951
Mail
Distribution: (1) YMCA of Metropolitan Dallas/
Mr. Todd Baker
(1) YMCA of Metropolitan Dallas/
Mr. Curt Hazelbaker
(1) City of Coppell/Mr. Kenneth Griffen
(1) Good Fulton & Farrell/
Mr. Scott Wegener
(1) Hill & Wilkinson/Mr. Lanny Huggins
(1) Dowdey Anderson & Associates/
Mr. Bill Anderson
Submitted by:
REED ENGINEERING GROUP, INC.
Original Signed By
Keith Atkins
KEA/je
2424 STUTZ DR. · SUITE 400 · DALLAS, TX75235 · T£L [214] 350 5600 · FAX [214] 3500019