YMCA-LR011221 (2) GEOTECHNICAL AND ENVIRONMENTAL CONSULTANTS CONCRETE CYLINDER TEST REPORT Coppell YMCA 146 Town Center Boulevard Coppell, Texas REPORTED TO: YMCA of Metropolitan Dallas 601 Akard Street Dallas, Texas 75201 AI-I'N: Mr. Todd Baker REPORT NO. 18 REG PROJECT NO. 8524 SAMPLE DATE: 01-03-02 TECHNICIAN: R. Bullion CONTRACTOR: Hill & Wilkinson Location of Sample Set Number J Location 1 J Quantity Represented Piers: A-1.5, A-1 and B-1 10/16 Design Information Source of Concrete [ Mix Identification LMC 49 Specified Strength p.s.i. 3OOO Test Results Set Cylinder Age @ No. ID Date Tested Test 1 6059 01-10-02 7 6059 01-31-02 28 6059 01-31-02 28 6059 Hold H Total Load lbs. 100210 Compressive Strength p.s.i. 355O Average Strength p.s.i. Cylinder Data Set Cylinder Time of No. ID Slump Sample Air Temp. 6059 5.50 12:30PM 33 Concrete Air Ticket Temp. Entrainment Number 54 N/A 06-740889 Mail Distribution: (1) YMCA of Metropolitan Dallas/ Mr. Todd Baker (1) YMCA of Metropolitan Dallas/ Mr. Curt Hazelbaker (1) City of Coppell/Mr. Kenneth Griffen (1) Good Fulton & Farrell/ Mr. Scott Wegener (1) Hill & Wilkinson/Mr. Lanny Huggins (1) Dowdey Anderson & Associates/ Mr. Bill Anderson Submitted by: REED ENGINEERING GROUP, INC. Original Signed By Keith Atkins KEA/je 2424 STUTZDR. · SUITE400 · DALLAS, TX 75235 · TEL [214] 350 5600 · FAX [214] 3500019 GEOTECHNICALAND G Jc~J O I I j~ ENVIRONMENTAL CONSULTANTS CONCRETE CYLINDER TEST REPORT Coppell YMCA 146 Town Center Boulevard Coppell, Texas REPORTED TO: YMCA of Metropolitan Dallas 601 Akard Street Dallas, Texas 75201 ATTN: Mr. Todd Baker REPORT NO. 14 REG PROJECT NO. 8524 SAMPLE DATE: 12-21-01 TECHNICIAN: S. Davis CONTRACTOR: Hilt & Wilkinson Location of Sample Set Number J Location J Quantity Represented 1 Piers: C.9-2,9, A-2.2,. 2A-2.6 10/10 Design Information Source of Concrete J Mix Identification I Specified Strength p.s.i. LMC 49 3000 Test Results Set Cylinder Age @ Total Load Compressive Average No. ID Date Tested Test lbs. Strength p.s.i. Strength p.s.i. 5870 12-28-01 7 80260 2840 5870 01-18-02 28 97770 3460 5870 01-18-02 28 102040 3610 3540 5870 Hold H Cylinder Data Set Cylinder Time of Concrete Air Ticket N1. ID Slump Sample Air Temp. Temp. Entrainment Number 5870 5.00 11:45AM 54 61 N/A 111150 Mail Distribution: (1) YMCA of Metropolitan Dallas/ Mr. Todd Baker (1) YMCA of Metropolitan Dallas/ Mr. Curt Hazelbaker (1) City of Coppell/Mr. Kenneth Griffen (1) Good Fulton & Farrell/ Mr. Scott Wegener (1) Hill & Wilkinson/Mr. Lanny Huggins (1) Dowdey Anderson & Associates/ Mr. Bill Anderson Submitted by: REED ENGINEERING GROUP, INC. Original Signed By Keith Atkins KEA/je 2424 STUTZ DR. · SUITE 400 · DALLAS, TX 75235 · TEL [214] 350 5600 · FAX [214] 350 0019