Loading...
YMCA-LR011220GEOTECHNICAL AND G R I-'1 U ~ ENVIRONMENTAL CONSULTANTS CONCRETE CYLINDER TEST REPORT Coppell YMCA 146 Town Center Boulevard Coppell, Texas REPORTED TO: YMCA of Metropolitan Dallas 601 Akard Street Dallas, Texas 75201 ATTN: Mr. Todd Baker CONTRACTOR: Hill & Wilkinson Location of Sample Set Number I Location 1 Paving: 75'W, 150'S of S.W. building corner REPORT NO. 13 REG PROJECT NO. 8524 SAMPLE DATE: 12-21-01 TECHNICIAN: S. Davis Quantity Represented 0~20 Design Information l Source of Concrete I Mix Identification I Specified Strength p.s.i. LMC 41 4000 Test Results Set Cylinder Age @ Total Load Compressive No. ID Date Tested Test lbs. Strength p.s.i. 1 5871 12-28-01 7 97960 3470 5871 01-18-02 28 129890 4600 5871 01-18-02 28 137050 4850 5871 Hold H Average Strength p.s.i. 473O Cylinder Data Set Cylinder Time of Concrete Air Ticket No. ID Slump Sample Air Temp. Temp. Entrainment Number 5871 4.00 10:00AM 48 54 4.2 740795 Mail Distribution: (1) YMCA of Metropolitan Dallas/ Mr. Todd Baker (1) YMCA of Metropolitan Dallas/ Mr. Curt Hazelbaker (1) City of Coppell/Mr. Kenneth Griffen (1) Good Fulton & Farrell/ Mr. Scott Wegener (1) Hill & Wilkinson/Mr. Lanny Huggins (1) Dowdey Anderson & Associates/ Mr. Bill Anderson Submitted by: REED ENGINEERING GROUP, INC. Original Signed By Keith Atkins KEA/je 2424 STUTZ DR * SUITE 400 · DALLAS, TX 75235 · TEl. [214] 350 5600 · FAX [214] 350 0019 GEOTECHNICAL AND ~ ~ r~l U P ~NVIRON~IENTAL EONSULTANT$ CONCRETE CYLINDER TEST REPORT Coppell YMCA 146 Town Center Boulevard Coppell, Texas REPORTED TO: YMCA of Metropolitan Dallas 601 Akard Street Dallas, Texas 75201 ATTN: Mr. Todd Baker REPORT NO. 11 REG PROJECT NO. 8524 SAMPLE DATE: 12-20-01 TECHNICIAN: S. Davis CONTRACTOR: Hill & Wilkinson Location of Sample [ SetNumber ILocation I Quantity Represented 1 Piers: D-2, 5.A-2.8 and .5.A-2.6 8/8 Design Information [S°urce °f C°ncrete ILMC Mix Identification 49 I Specified Strength P's'i' Test Results Set Cylinder Age @ Total Load Compressive No. ID Date Tested Test lbs. Strength p.s.i. 1 5872 12-27-01 7 74180 2630 5872 01-17-02 28 117860 4170 5872 01-17-02 28 109250 3870 5872 Hold H Average Strength p.s.i. 4O2O Cylinder Data Set Cylinder Time of Concrete Air Ticket N1o. ID Slump Sample Air Temp. Temp. Entrainment Number 5872 4.50 12:30PM 56 59 N/A 111063 Mail Distribution: (1) YMCA of Metropolitan Dallas/ Mr. Todd Baker (1) YMCA of Metropolitan Dallas/ Mr. Curt Hazelbaker (1) City of Coppell/Mr. Kenneth Griffen (1) Good Fulton & Farrell/ Mr. Scott Wegener (1) Hill & Wilkinson/Mr. Lanny Huggins (1) Dowdey Anderson & Associates/ Mr. Bill Anderson Submitted by: REED ENGINEERING GROUP, Original Signed By Keith Atkins KEA/je INC. 2424 STUTZ DR. · SUITE 400 · DALLAS, TX 75235 · TEL [214] 350 S600 · fAX [214] 350 0019