YMCA-LR011220 (2) GEOTECHNICAL AND ENVIP, ONMENTAL CONSULTANTS CONCRETE CYLINDER TEST REPORT Coppell YMCA 146 Town Center Boulevard Coppell, Texas REPORTED TO: YMCA of Metropolitan Dallas 601 Akard Street Dallas, Texas 75201 ATTN: Mr. Todd Baker REPORT NO. 11 REG PROJECT NO. 8524 SAMPLE DATE: 12-20-01 TECHNICIAN: S. Davis CONTRACTOR: Hill & Wilkinson Location of Sample Set Number I Location I Quantity Represented 1 Piers: D-2, 5.A-2.8 and .5.A-2.6 8/8 Design Information Source of Concrete I Mix Identification I Specified Strength p.s.i. LMC 49 3000 Test Results Set Cylinder Age @ Total Load Compressive No. D Date Tested Test lbs. Strength p.s.i. 1 5872 12-27-01 7 74180 2630 5872 01-17-02 28 5872 01-17-02 28 5872 Hold H Average Strength p.s.i. Cylinder Data Set Cylinder Time of Concrete Air Ticket N1o. ID Slump Sample Air Temp. Temp. Entrainment Number 5872 4.50 12:30PM 59 N/A 111063 Mail itted by: Distribution: (1) YMCA of Metropolitan Dallas/~ Mr. Todd Baker REED ENGINEERING GROUP, INC. (1) YMCA of Metropolitan Dallas/ Mr. Curt Hazelbaker Original Signed By (1) City of Coppell/Mr. Kenneth Griffen (1) Good Fulton & Farrell/ Keith Atkins Mr. Scott Wegener KEA/je (1) Hill & Wilkinson/Mr. Lanny Huggins (1) Dowdey Anderson & Associates/ Mr. Bill Anderson 2424 STUTZDR. * SUITE400 · DALLAS, TX 75235 · TEL [214] 350 5600 · FAX [214] 350 0019