Loading...
YMCA-LR020116 (2)CONCRETE CYLINDER TEST REPORT Coppell YMCA 146 Town Center Boulevard Coppell, Texas REPORTED TO: YMCA of Metropolitan Dallas 601 Akard Street Dallas, Texas 75201 ATTN: Mr. Todd Baker REPORT NO. 32 REG PROJECT NO. 8524 SAMPLE DATE: 01-16-02 TECHNICIAN: M. Banchetti CONTRACTOR: Hill & Wilkinson Location of Sample Set Number I Location 1 Pier Cap: E.9-1 Quantity Represented 3/3 Design Information Source of Concrete I Mix Identification LMC 38 Specified Strength p.s.i. 3OOO Test Results Set Cylinder Age @ Total Load Compressive Average No. ID Date Tested Test lbs. Strength p.s.i. Strength p.s.i. 1 6558 01-23-02 7 90500 3200 6558 02-13-02 28 6558 02-13-02 28 6558 Hold H Cylinder Data Set Cylinder Time of Concrete Air Ticket N . ID Slump Sample Air Temp. Temp. Entrainment Number ~3 6558 4.25 1:30PM 65 64 4.75 7112679 Mail Distribution: (1) YMCAof Metropolitan Dallas/ Mr. Todd Baker (1) YMCA of Metropolitan Dallas/ Mr. Curt Hazelbaker (1) City of Coppell/Mr. Kenneth Griffen (1) Good Fulton & Farrell/ Mr. Scott Wegener (1) Hill & Wilkinson/Mr. Lanny Huggins (1) Dowdey Anderson & Associates/ Mr. Bill Anderson Submitted by: REED ENGINEERING GROUP, INC. Original Signed By Keith Atkins KEA/je 2424 STUTZ DR. * SUITE 400 * DALLAS, TX 75235 * TEL [214] 350 5600 * FAX [214] 3S00019