YMCA-LR020116 (2)CONCRETE CYLINDER TEST REPORT
Coppell YMCA
146 Town Center Boulevard
Coppell, Texas
REPORTED TO: YMCA of Metropolitan Dallas
601 Akard Street
Dallas, Texas 75201
ATTN: Mr. Todd Baker
REPORT NO. 32
REG PROJECT NO. 8524
SAMPLE DATE: 01-16-02
TECHNICIAN: M. Banchetti
CONTRACTOR: Hill & Wilkinson
Location of Sample
Set Number I Location
1 Pier Cap: E.9-1
Quantity Represented
3/3
Design Information
Source of Concrete I Mix Identification
LMC 38
Specified Strength p.s.i.
3OOO
Test Results
Set Cylinder Age @ Total Load Compressive Average
No. ID Date Tested Test lbs. Strength p.s.i. Strength p.s.i.
1 6558 01-23-02 7 90500 3200
6558 02-13-02 28
6558 02-13-02 28
6558 Hold H
Cylinder Data
Set Cylinder Time of Concrete Air Ticket
N . ID Slump Sample Air Temp. Temp. Entrainment Number
~3 6558 4.25 1:30PM 65 64 4.75 7112679
Mail
Distribution: (1) YMCAof Metropolitan Dallas/
Mr. Todd Baker
(1) YMCA of Metropolitan Dallas/
Mr. Curt Hazelbaker
(1) City of Coppell/Mr. Kenneth Griffen
(1) Good Fulton & Farrell/
Mr. Scott Wegener
(1) Hill & Wilkinson/Mr. Lanny Huggins
(1) Dowdey Anderson & Associates/
Mr. Bill Anderson
Submitted by:
REED ENGINEERING GROUP, INC.
Original Signed By
Keith Atkins
KEA/je
2424 STUTZ DR. * SUITE 400 * DALLAS, TX 75235 * TEL [214] 350 5600 * FAX [214] 3S00019