Loading...
CF-Coppell Rd SC-LR020116 (2)Hooper Engineering Laboratories, Inc. CLIE LOCATION OF POUR SET 1: LOCATION OF POUR SET 2'. his Testing :RETE TESTS Texas Unified Construc Field ;~ Maint. Fac., C0ppell JOB NO.: 01.1054 DATE: 16 January 2002 SUPPLIER: Lattimore Grade beams at utility storage building, on line B from 1 to 5 and on line 3 from B to B.3 SAMPLE DATA: SET 1 SET 2 MIX NO. 54 Truck No. 01125 Cement Ticket No. 7112663 Flyash Time Batched 9:04am Sand Time Sampled 9:40am in. Concrete Temp. IASTM C1064] 57°F 1.0 in. Air Content (ASTM C231) Water Unit Weight (ASTM C138) Admix //1 Admix //2 AEA COMPRESSIVE STRENGTH TESTS (ASTM C39) (Standard 6 inch x 12 inch cylinder) Cylinder Slump Age Test Total Load Compressive Required Number Inches Days Date Pounds Strength 28-Day IASTM C143) psi Strength 93 4.50 7 01/23/02 94 4.50 28 02/I 3/02 95 4.50 28 02/13/02 TECHNICIAN: DISTRIBUTION: MFM (9:00am-11:00am) (3) City of Coppell (1) Vidaud & Associates (1) Doyle Engineering Group (1) Texas Unified Constructors, Inc, 105,600 3740 154,500 5470 160,800- 569Q~ 2S-Day Average 5580 3OOO 2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148