CF-Coppell Rd SC-LR020116 (2)Hooper Engineering Laboratories, Inc.
CLIE
LOCATION OF POUR SET 1:
LOCATION OF POUR SET 2'.
his Testing
:RETE TESTS
Texas Unified Construc
Field ;~ Maint. Fac., C0ppell
JOB NO.: 01.1054
DATE: 16 January 2002
SUPPLIER: Lattimore
Grade beams at utility storage building, on line B
from 1 to 5 and on line 3 from B to B.3
SAMPLE DATA: SET 1 SET 2 MIX NO. 54
Truck No. 01125 Cement
Ticket No. 7112663 Flyash
Time Batched 9:04am Sand
Time Sampled 9:40am in.
Concrete Temp. IASTM C1064] 57°F 1.0 in.
Air Content (ASTM C231) Water
Unit Weight (ASTM C138) Admix //1
Admix //2
AEA
COMPRESSIVE STRENGTH TESTS (ASTM C39)
(Standard 6 inch x 12 inch cylinder)
Cylinder Slump Age Test Total Load Compressive Required
Number Inches Days Date Pounds Strength 28-Day
IASTM C143) psi Strength
93 4.50 7 01/23/02
94 4.50 28 02/I 3/02
95 4.50 28 02/13/02
TECHNICIAN:
DISTRIBUTION:
MFM (9:00am-11:00am)
(3) City of Coppell
(1) Vidaud & Associates
(1) Doyle Engineering Group
(1) Texas Unified Constructors, Inc,
105,600 3740
154,500 5470
160,800- 569Q~
2S-Day Average 5580
3OOO
2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148