Windsor Estates-LR010531· REPORT OF DRILLED BELLED PIER INSPECTION
Report Number: 94011150.0009
Service Date: May 11,2001
Client: Excel Group, Inc.
Attn: Kelly Jordan
2639 Walnut Hill Ln #218
Dallas TX 75229
Report Date: May 31,2001
Project: Jordan Residence
Lot 14, DeForest Road
Coppell, Texas
Project Number: 94011150
8901 Carpenter Frwy., Suite #100
Dallas, Texas 75247
(214) 630-1010
Services: Drilled belled pier inspection.
On this date, an HBC Engineering technician arrived at the above referenced jobsite as scheduled for
drilled belled pier inspection. See the attached sheet for recorded data.
Technician: Terry L. Smith
Report Distribution:
(1) Excel Group, Inc.
(1) City of CoppeH - Constr Insp
(1) City of Coppell- Bldg Insp
Reviewed
~rJc J. Cleveland, P.E.
Senior Project Engineer
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessariJy indicative of the properties of other apparently similar or identical
materials.
REPORT OF DRILLED BELLED PIER INSPECTION
Report Number: 94011150.0011
Service Date: May 14, 2001
8901 Carpenter Frwy., Suite #100
Dallas, Texas 75247
(214) 630-1010
Client: Excel Group, Inc.
Attn: Kelly Jordan
2639 Walnut Hill Ln #218
Dallas TX 75229
Report Date: May 31,2001
Project: Jordan Residence
Lot 14, DeForest Road
Coppell, Texas
Project Number: 94011150
Services: Drilled belled pier inspection.
On this date, an HBC Engineering technician arrived at the above referenced jobsite as scheduled for
drilled belled pier inspection. See the attached sheet(s) for recorded data.
Technician: Terry L Smith
Report Distribution:
(1) Excel Group, Inc.
(1) City of Coppell - Constr Insp
(1) City of Coppell - Bldg Insp
Reviewed by: ~
Eric J. Cleveland, P.E.
Senior Project Engineer
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not bo reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.