Windsor Estates-LR010221 (2)"CONCRETE COMPRESSIVE STRENGTH TEST Client: Excel Group, Inc. Attn: Bryan Peck 2639 Walnut Hill Ln #218 Dallas TX 75229 Dallas, Texas 75247 (214) 630-1010 Report Date: Project: February 21,2001 Windsor Estates Coppell, Texas Service Date: January 22, 2001 Project Number: 94001501 Report Number: 94001501.0003 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 9:27am Supplier: TXl Truck No: 59 Mix I.D. No.: 8204 Plant: 41 Ticket No: 2810659 Sample Information Sample Time: 9:51 am Technician: Darrin Phillips Weather Conditions: Sunny, clear Accumulative Yards: 50 Placement Method: Direct discharge Sample Locations: Sta. 2+04 Placement Location: St;' James Street Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,O F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Set Specimen Diameter No. ID (inches) 2C 1 6.00 2C 2 6.00 Result 2.50 4.3 51 40 Specification 2 max 3-5 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 01/29/2001 7 107,550 3,800 01/29/2001 7 117,320 4,150 Average 3,980 2C 3 6.00 02/19/2001 28 129,110 4,570 2C 4 6.00 02/19/2001 28 134,980 4,770 Average 4,670 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM test methods. This repor~ is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terra(on. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 5 o, ~.~,,.o,.~.,..~ . CONCRETE COMPRESSIVE STRENGTH TEST 8901 carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Excel Group, Inc. Attn: Bryan Peck 2639 Walnut Hill Ln #218 Dallas TX 75229 Report Date: Project: February 21, 2001 Windsor Estates Coppell, Texas Service Date: January 22, 2001 Project Number: 94001501 Report Number: 94001501.0003 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 11:48am Supplier: TXI Truck No: 38 Mix I.D. No.: 8204 Plant: 41 Ticket No: 2810897 Sample Information Sample Time: 12:30pm Technician: Darrin Phillips Weather Conditions: Sunny, clear Accumulative Yards: 250 Placement Method: Direct discharge Sample Locations: Sta. 13+69 Placement Location: DGForest Street Field Test Data Test Result Specification Slump, inches: 2.00 2 max Air Content, %: 4.2 3-5 Concrete Temperature,O F: 59 Ambient Temperature, o F: 53 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Date Test Load Strength No. ID (inches) Tested (days) (lbs) (psi) 3C 1 6.00 01/29/2001 7 89,040 3,150 3C 2 6.00 01/29/2001 7 94,290 3,330 Average 3,240 3C 3 6.00 02/19/2001 28 157,810 5,580 3C 4 6.00 02/19/2001 28 137,590 4,870 Average 5,230 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in tull without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 5 o,~,w~ CONCRETE COMPRESSIVE STRENGTH TEST 8901 carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Excel Group, Inc. Attn: Bryan Peck 2639 Walnut Hill Ln #218 Dallas TX 75229 Report Date: Project: February 21,2001 Windsor Estates Coppell, Texas Service Date: January 22, 2001 Project Number: 94001501 Report Number: 94001501.0003 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 1:34pm Supplier: TXI Truck No: 712 Mix I.D. No.: 8204 Plant: 41 Ticket No: 2811123 Sample Information Sample Time: 2:21 pm Technician: Darrin Phillips Weather Conditions: Sunny, clear Accumulative Yards: 400 Placement Method: Direct discharge Sample Locations: Sta. 11+52 Placement Location: D~Forest Street Field Test Data Test Result Specification Slump, inches: 2.50 2 max Air Content, %: 4.4 3-5 Concrete Temperature,O F: 58 Ambient Temperature, 0 F: 56 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Date Test Load Strength No. ID (inches) Tested (days) (lbs) (psi) 4C 1 6.00 01/29/2001 7 90,330 3,190 4C 2 6.00 01/29/2001 7 84,410 2,980 Average 3,090 4C 3 6.00 02/19/2001 28 117,310 4,150 4C 4 6.00 02/19/2001 28 123,370 4,360 Average 4,260 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. · CONCRETE COMPRESSIVE STRENGTH TEST 8901 carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Excel Group, Inc. Attn: Bryan Peck 2639 Walnut Hill Ln #218 Dallas TX 75229 Report Date: Project: February 21,2001 Windsor Estates Coppell, Texas Service Date: January 22, 2001 Project Number: 94001501 Report Number: 94001501.0003 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 3:14pm Supplier: TXI Plant: 41 Truck No: 66 Ticket No: 2811307 Mix I.D. No.: 8204 Sample Information Sample Time: 4:00pm Technician: Darrin Phillips Weather Conditions: Sunny, clear Accumulative Yards: 550 Placement Method: Direct discharge Sample Locations: Sta. 8+51 Placement Location: DeForest Street Field Test Data Test Result Specification Slump, inches: 2.00 2 max Air Content, %: 4.5 3-5 Concrete Temperature,O F: 59 Ambient Temperature, o F: 57 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Date Test Load Strength No. ID (inches) Tested (days) (lbs) (psi) 5C 1 6.00 01/29/2001 7 111,140 3,930 5C 2 6.00 01/29/2001 7 112,650 3,980 Average 3,960 5C 3 6.00 02/19/2001 28 172,000 6,080 5C 4 6.00 02/19/2001 28 167,180 5,910 Average 6,000 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CONCRETE COMPRESSIVE STRENGTH TEST 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Excel Group, Inc. Attn: Bryan Peck 2639 Walnut Hill Ln #218 Darlas TX 75229 Report Date: Project: February 21,2001 Windsor Estates Coppell, Texas Service Date: January 22, 2001 Project Number: 94001501 Report Number: 94001501.0003 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: Supplier: TXI Plant: 41 Truck No: 804 Ticket No: 2811435 Mix I.D. No.: 8204 Sample Information Sample Time: 5:50pm Technician: Darrin Phillips Weather Conditions: Cloudy, cool Accumulative Yards: 700 Placement Method: Direct discharge Sample Locations: Sta. 6+00 Placement Location: De'Forest Street Field Test Data Test Result Specification Slump, inches: 2.00 2 max Air Content, %: 4.4 3-5 Concrete Temperature,o F: 59 Ambient Temperature, o F: 51 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Date Test Load Strength No. ID (inches) Tested (days) (lbs) (psi) 6C 1 6.00 01/29/2001 7 117,320 4,150 6C 2 6.00 01/29/2001 7 113,080 4,000 Average 4,080 6C 3 6.00 02/19/2001 28 123,030 4,350 6C 4 6.00 02/19/2001 28 142,760 5,050 Average 4,700 Services - Obtain samples of fresh concrete at the placement locations, pedorm required field tests and cast compressive strength samples. Repod Distribution: Inc. (1) Excel Group, Inc. (1) City of Coppell - Engr Dept Reviewed by: (1) city of Coppell - Bldg Insp ~--/Enc"~. Cleveland, P.E. Senior Project Engineer The tests were performed in general accordance with applicable ASTM test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terrecon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 5 o, ~_w~,.F~,o,~,