Windsor Estates-LR010202CONCRETE COMPRESSIVE STRENGTH TEST
Client: Excel Group, Inc.
Attn: Bryan Peck
2639 Walnut Hill Ln #218
Dallas TX 75229
Report Date:
Project:
890t Carpenter Rwy., Suite #10o
Dallas, Te),as 75247
(214) 630-1010
February 02, 2001
Windsor Estates
Coppell, Texas
Service Date: January 23, 2001
Project Number: 94001501
Report Number: 94001501.0004
Material Information
Specified Strength: 4000 psi ~ 28 Days
Batch Time: 7:46am
Supplier: TXI
Truck No: 644
Mix I.D. No.: 8206
Plant: 41
Ticket No: 2811715
Sample Information
Sample Time: 8:18am
Technician: Dardn Phillips
Weather Conditions: Sunny, cool
Accumulative Yards: 70
Placement Method: Direct discharge
Sample Locations: Sta. 16+09
Placement Location: Paving
Field Test Data
Test Result Specification
Slump, inches: 4.00 4.0 Max
Air Content, %: 4.1 3-5
Concrete Temperature? F: 55
Ambient Temperature, O F: 41
Plastic Unit Weight, pcf:
Laboratory Test Data
Age at Maximum Compressive
Set Specimen Diameter Date Test Load Strength
No. ID (inches) Tested (days) (lbs) (psi)
7C 1 6.00 01/30/2001 7 161,140 5,700
7C 2 6.00 01/30/2001 7 159,440 5,640
Average 5,670
7C 3 02/20/2001 28
7C 4 02/20/2001 28
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
Technician: Damn Phillips
Report Distribution:
(1) Excel Group, Inc.
(1) City of Coppell - Engr Dept
(1) City of Coppell - Bldg Insp
Reviewed by:
Eric J. Cleveland, P.E.
Senior Project Engineer