Loading...
Windsor Estates-LR010514CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94011150.0004 Service Date: May 2, 2001 8901 Carpenter Fn,vy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Excel Group, Inc. Attn: Kelly Jordan 2639 Walnut Hill Ln #218 Dallas TX 75229 Report Date: May 14, 2001 Project: Jordan Residence Lot 14, DeForest Road Coppell, Texas Project Number: 94011150 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 2:50pm Supplier: Redi-Mix Truck No: 273 Mix I.D. No.: 914 Plant: 1 Field Test Data Test Ticket No: 16210 Sample Information Sample Time: 3:22pm Technician: Gerry Graham Weather Conditions: Fair, partly cloudy Accumulative Yards: 10 Placement Method: Direct discharge Sample Locations: 6,7,8,10,12,13,14, 17, 24 & 28 Placement Location: Piers Result Specification Test Method Slump, inches: 5.75 5-7 ASTM C-143 Air Content, %: N/A ASTM C-172 Concrete Temperature, O F: 84 ASTM C-39 Ambient Temperature, o F: 84 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Date Test Load Strength No. ID (inches) Tested (days) (lbs) (ps[) 1 1 6.00 05/09/2001 7 105,970 3,750 1 2 6.00 05/09/2001 7 108,230 3,830 Average 3,790 1 3 05/30/2001 28 1 4 05/30/2001 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Gerry Graham Report Distribution: (1) Excel Group, Inc. (1) City of Coppell - Constr Insp (1) City of Coppell - Bldg Insp Reviewed by: Senior Project Engineer The tests were pedormed in general accordance with applicable ASTM test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. · REPORT OF DRILLED BELLED PIER INSPECTION Report Number: 94011150.0005 Service Date: May 3, 2001 8901 Carpenter Fr,,vy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Excel Group, Inc. Attn: Kelly Jordan 2639 Walnut Hill Ln #218 Dallas TX 75229 Report Date: May 14, 2001 Project: Jordan Residence Lot 14, DeForest Road Coppell, Texas Project Number: 94011150 Services: Drilled belled pier inspection. On this date, an HBC Engineering technician arrived at the above referenced jobsite as scheduled for drilled belied pier inspection. See attached sheets for recorded data. Report Distribution: (1) Excel Group, Inc. (1) City of Coppell - Constr Insp Reviewed by: (1) City of Coppell - Bldg Insp EricJ Cleveland P E Senior Project Engineer The tests were performed in general accordance with applicable ASTM test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the wri[ten approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the proper[les of other apparently similar or identical materials.