Windsor Estates-LR010920CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94001501.0026 Service Date: September 11,2001 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 680-1010 Client: Excel Group, Inc. Attn: Bryan Peck 2639 Walnut Hill Ln #218 Dallas TX 75229 Report Date: September 20, 2001 Project: Windsor Estates Coppell, Texas Project Number: 94001501 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 7:55am Supplier: TXI Truck No: 67 Mix I.D. No.: 8204SF Plant: 41 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, O F: Ambient Temperature, 0 F: Plastic Unit Weight, pcf: Laboratory Test Data Result 3.50 87 73 Set Specimen Diameter Area No. ID (inches) (sq. inches) 1 I 6.00 28.27 1 2 6.00 28.27 1 3 1 4 Ticket No: 2976559 Sample Information Sample Time: 8:30am Date Cast: September 11, 2001 Technician: Roy Montgomery Weather Conditions: Clear Accumulative Yards: 40 Placement Method: Sample Locations: Sta. 5+90 Placement Location: Paving- DeForest Specification 3.0 Max Test Method ASTM C-143 ASTM C-173 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 09/18/2001 7 94,410 3,340 09/18/2001 7 91,360 3,230 Average 3,290 10/09/2001 28 10/09/2001 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94001501.0026 Service Date: September 11, 2001 5901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Excel Group, Inc. Attn: Bryan Peck 2639 Walnut Hill Ln #218 Dallas TX 75229 Report Date: September 20, 2001 Project: Windsor Estates Coppell, Texas Project Number: 94001501 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 9:07am Supplier: TXI Truck No: 67 Mix I.D. No.: 8204SF Plant: 41 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 3.00 86 82 Set Specimen Diameter Area No. ID (inches) (sq. inches) 2 1 6.00 28.27 2 2 6.00 28.27 2 3 2 4 Ticket No: 2976674 Sample Information sample Time: 9:35am Date Cast: September 11,2001 Technician: Roy Montgomery Weather Conditions: Clear Accumulative Yards: 120 Placement Method: Sample Locations: Sra. 4+60 Placement Location: See page 1 Specification 3.0 Max Test Method ASTM C-143 ASTM C-173 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 09/1812001 7 104,480 3,690 09/18/2001 7 103,840 3,670 Average 3,680 10/09/2001 28 10/09/2001 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94001501.0026 Service Date: September 11, 2001 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Excel Group, Inc. Attn: Bryan Peck 2639 Walnut Hill Ln #218 Dallas TX 75229 Report Date: September 20, 2001 Project: Windsor Estates Coppell, Texas Project Number: 94001501 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 10:39am Supplier: TXI Truck No: 39 Mix I.D. No.: 8204SF Plant: 41 Field Test Data Test Result Slump, inches: 2.50 Air Content, %: 4.9 Concrete Temperature,O F: 77 Ambient Temperature, o F: 80 Plastic Unit Weight, pcf: Laboratory Test Data Ticket No: 2976839 Sample Information Sample Time: 11:00am Date Cast: September 11,2001 Technician: Roy Montgomery Weather Conditions: Clear Accumulative Yards: 220 Placement Method: Sample Locations: 2+90 Placement Location: See page 1 Specification 3.0 Max Test Method ASTM C-143 ASTM C-173 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 3 I 6.00 28.27 09/18/2001 7 95,140 3,360 3 2 6.00 28.27 09/18/2001 7 100,310 3,550 Average 3,460 3 3 10/09/2001 28 3 4 10/09/2001 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were per(ormed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use ef the client indicated above and shall not be reproduced except in 1ull without the wdtten approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94001501.0026 Service Date: September 11, 2001 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Excel Group, Inc. Attn: Bryan Peck 2639 Walnut Hill Ln #218 Dallas TX 75229 Report Date: September 20, 2001 Project: Windsor Estates Coppel[, Texas Project Number: 94001501 Material Information Specified Strength: 3000 psi ~ 28 Days Batch Time: 11:46am Supplier: TXI Truck No: 67 Mix I.D. No.: 8204SF Plant: 41 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,O F: Ambient Temperature, O F: Plastic Unit Weight, pcf: Laborator~ Test Data Ticket No: 2976979 Sample Information Sample Time: 12:35pm Date Cast: September 11,2001 Technician: Roy Montgomery Weather Conditions: Clear Accumulative Yards: 330 Placement Method: Sample Locations: Sra. 0+90 Placement Location: See page 1 Result Specification Test Method 2.50 3.0 Max ASTM C-143 5.0 ASTM C-173 90 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 4 1 6.00 28.27 09/18/2001 7 103,370 3,660 4 2 6.00 28.27 09/18/2001 7 109,490 3,870 Average 3,770 4 3 10/09/2001 28 4 4 10/09/2001 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Roy Montgomery ~~ee Report Distribution: lng, Inc. (1) Excel Group, Inc. (1) City of Coppell ~ Engr Dept Reviewed by: (1) city of Coppell - Bldg Insp ~ ~ E~c J. Cleveland, P.E. S~ior Project Engineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properiies of other apparently similar or identical materials CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94001501.0027 Service Date: September 11,2001 89Ol Carpenter F~Ny., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Excel Group, Inc. Attn: Bryan Peck 2639 Walnut Hill Ln #218 Dallas TX 75229 Report Date: September 20, 2001 Project: Windsor Estates Coppell, Texas Project Number: 94001501 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 1:04pm Supplier: TXI Truck No: 65 Mix I.D. No.: 8206 Plant: 41 Field Test Data Test Ticket No: 2877138 Sample Information sample Time: 1:35pm Date Cast: September 11, 2001 Technician: HBC Fort Worth Office Weather Conditions: Clear Accumulative Yards: 20 Placement Method: Direct Discharge Sample Locations: See placement location Placement Location: Paving Result Specification Test Method Slump, inches: 4.00 3-5 ASTM C-143 Air Content, %: 4.5 3-6 ASTM C-231 Concrete Temperature,° F: 87 ASTM C1064 Ambient Temperature, 0 F: 80 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 1 6.00 28.27 09/18/2001 7 138,250 4,890 1 2 6.00 28.27 09/18/2001 7 147,880 5,230 Average 5,060 1 3 10/09/2001 28 1 4 10/09/2001 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. · CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94001501.0027 Service Date: September 11,2001 8901 Carpenter Rwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Excel Group, Inc. Attn: Bryan Peck 2639 Walnut Hill Ln #218 Dallas TX 75229 Report Date: September 20, 2001 Project: Windsor Estates Coppell, Texas Project Number: 94001501 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 2:45pm Supplier: TXI Truck No: 713 Mix I.D. No.: 8206 Plant: 41 Ticket No: Field Test Data Test Result Slump, inches: 4.00 Air Content, %: 5.0 Concrete Temperature, o F: 78 Ambient Temperature, 0 F: 82 Plastic Unit Weight, pcf: Laboratory Test Data Sample Information Sample Time: Date Cast: September 11, 2001 Technician: HBC Fort Worth Office Weather Conditions: Clear Accumulative Yards: 100 Placement Method: Direct Discharge Sample Locations: 15' S of N line/10' E Placement Location: See page 1 Specification Test Method 3-5 ASTM C-143 3-6 ASTM C-231 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 2 1 6.00 28.27 09/18/2001 7 1321900 4,700 2 2 6.00 28.27 09/18/2001 7 135,410 4,790 Average 4,750 2 3 10/09/2001 28 2 4 10/09/2001 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: HBC Fort Worth Office Report Distribution: (1) Excel Group, Inc. (1) City of Coppelr - Engr Dept (1) City of Codpell - Bldg Insp Reviewed by: Senior Project Engineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This repot[ is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical matedals.