Loading...
CF-Coppell Rd SC-LR020117 (2)Hooper En'gineering Laboratories, Inc. Construction Materials Testing REPORT OF CONCRETE TESTS JOB NO.: C~_ Texas Unified Constructors, In DATE: PROJECT: Field Service ~es & Mmnt. Fac., Coppell SUPPLIER: LOCATION OF POUR SET 1: Grade beam, line 3 & 5 @ Bldg. 2 LOCATION OF POUR SET 2: 01.1054 17 January 2002 Lattimore SAMPLE DATA: SET 1 SET 2 MIX NO. Truck No. 1106 Cement Ticket No. 3139504 Flyash Time Batched 12:30pm Sand Time Sampled 1:30pm in. Concrete Temp. (ASTM C1064) 60°F 1.0 in. Air Content IASTM C231) Water Unit Weight (ASTM C138) Admix #1 Admix //2 AEA 54 COMPRESSIVE STRENGTH TESTS (ASTM C39) (Standard 6 inch x 12 inch cylinder) Cylinder Slump Age Test Total Load Compressive Required Number Inches Days Date Pounds Strength 2S-Day {ASTM C143) psi Strength 96 3.75 01/24/02 97 3.75 ~ 28 ~,~ 02/14/02 98 3.75 ~ 02/14/02 106,400 3760 156,600 SS40,i,~ 160,400 5670f 28-Da¥ Average 5610 3O0O TECHNICIAN: DISTRIBUTION: CBC (1:00pm-2:30pm) (3) City of Coppell (1) Vidaud & Associates (1) Doyle Engineering Group (1) Texas Unified Constructors, Inc. 2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148