Loading...
CF-Coppell Rd SC-LR020118 (2)Hooper Engineering Laboratories, Inc. Construction Materials Testing REPORT OF CONCRETE TESTS CLIENT: Texas Unified Constructors, Inc. PROJECT: Field Service Offices & Maint. Fac., Coppell LOCATION OF POUR SET 1: Grade beam, Bldg. 2, line B & D between 6 and 10 LOCATION OF POUR SET 2: JOB NO.: 01.1054 DATE: 18 January 2002 SUPPLIER: Lattimore SAMPLE DATA: SET I SET 2 MiX NO. Truck No. 1040 Cement Ticket No. 7112772 Flyash Time Batched 1:30pm Sand Time Sampled 2:15pm in. Concrete Temp. (ASTM CI064) 58°F 1.0 in. Air Content (ASTM C231) Water Unit Weight (ASTM C138) Admix #1 Admix #2 AEA 54 COMPRESSIVE STRENGTH TESTS (ASTM C39) (Standard 6 inch x 12 inch c¥1inder) Cylinder Slump Age Test Total Load Compressive Required Number Inches Days Date Pounds Strength 28-Day (ASTM C143) psi Strength 99 3.25 7 01 ~25~02 95,700 3390 100 3.25 28 02/15/02 132,200 4680 101 3.25 28 02/15/02 137,000 4850 28-Day Average 4780 3000 TECHNICIAN: DISTRIBUTION: CBC (2:00pm-3:30pm) (3) City of Coppell (1) Vidaud & Associates (1) Doyle Engineering Group (1) Texas Unified Constructors, Inc. 2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148