Loading...
Amberpoint BP-LR020209 (2)WATER INJECTION OBSERVATION Date of Service: Client No.: Client: Location: Procedure: 02/09/02 3181 Transwestem Commercial Services 5001 Spring Valley Rd, Suite 600 W Dallas, TX 75244 Report No.: Project No.: Project: Building Pad General Contractor: Injector: 94021029.0046 94021029 Amberpoint Building No. 1 Amberpoint Bus. Pk ~ Coppell Coppell, Texas Hill & Wilkinson Jowell On this date, a representative of HBC Engineering, Inc. observed the injection of water at this site. During the injection process, the following observations were recorded. Pass No.: 6th No. of Probes: 4 Probe Length: 10 feet OBSERVATION SPECIFICATION Yes No N/A Surfactant added to each load. X Injection pressure 50 to 200 psi at manifold. X Injection downward in 18 inch intervals. X Total depth of injection was 7 feet. X Spacing of injection was 5 feet maximum. X Iqjection to refusal at each location. X Comments: Technician: M. Arandia Report Distribution: (l) Transwcstem Commercial Services (1) O'Brien & Associates, Inc. (1) TechniStmctures, Inc. (1) City of Coppell - Constr. Insp. (1) City of Coppeil -Bldg. lnsp. (1) ltill & Wilkinson, Ltd. (1) Halff Associates (1) State Farm Insurance m~ Engineering, Inc. Eugene Harbour Principal 99ss This re~ort is exclusively for the use of the client indicated above and shall not be reprcduced in full witho~ wrfften approval of HBC Engineer