Loading...
Amberpoint BP-LR020201WATER INJECTION OBSERVATION ENGINEEPdNG, INC. Date of Service: 02/01/02 Client No.: ~ -~. Clie~,~[ranswestem Comm~ices % f 5001Spri~, Suite 600W · D as 75244 Location: Report No.: Project No.: Project: Building Pad, lines 5.5 to 11, M to General Contractor: N.5 & lines 10 to 11, G to L.5 Iniector: 94021029.0031 94021029 Amberpoint Building No. 1 Amberpoint Bus. Pk @ Coppell Coppell, Texas Hill & Wilkinson Jowell Procedure: On this date, a representative of HBC Engineering, Inc. observed the injection of water at this site. During the injection process, the following observations were recorded. Pass No.: 2nd & 3rd No. of Probes: 4 Probe Length: 10 feet OBSERVATION SPECIFICATION Yes No N/A Surfactant added to each load. X Injection pressure 50 to 200 psi at manifold. X Injection downward in 18 inch intervals. X Total depth of injection was 10 feet. X Spacing of injection was 5 feet maximum. X In, iection to refusal at each location. X Comments: Technician: S. Long Report Distribution: (1) Transwestem Commercial Services (1) O'Brien & Associates, inc. ( 1 ) TechniStructures. Inc. (I) City of Coppell - Constr. lnsp. (1) City of Coppell - Bldg. lnsp. (1) Hill & Wilkinson, Ltd. ( 1 ) Halff Associates (1) State Farm Insurance ~ Engineering, Inc. Eugene Harbour Principal 99ss This report is exclusively for the use of the client indicated above and shall not be reproduced in full without writlen approval of HBC Engineer ® ??? ?? ?? WATER INJECTION OBSERVATION ENGINEERING, INC. Date of Service: Client No.: Client: 02/01/02 3181 Transwestern Commercial Services 5001 Spring Valley Rd., Suite 600W Dallas, Texas 75244 Report No.: Project No.: Project: 94021029.0030 94021029 Amberpoint Building No. ! Amberpoint Bus. Pk @ Coppell Coppell, Texas Location: Building Pad General Contractor: Hill & Wilkinson Injector: Jowell Procedure: On this date, a representative of I:tBC Engineering, Inc. observed the injection of water at this site. During the injection process, the following observations were recorded. Pass No.: 4th No. of Probes: 4 Probe Length: 12 feet OBSERVATION SPECIFICATION Yes No N/A Surfactant added to each load. X Injection pressure 50 to 200 psi at manifold. X Injection downward in 18 inch intervals. X Total depth of injection was i0 feet. X Spacin~ of injection was 5 feet maximum. X Iniection to refusal at each location. X Comments: Technician: S. Campbell Report Distribution: (I) Transwestem Commercial Services (1) O'Brien & Associates, Inc. (1) TechniStmctures, Inc. (I) City of Coppell - Const~. Insp. (1) City of Coppell - Bldg. lnsp. (1) Hill & Wilkinson, Ltd ( 1 ) Halff Associates (1) State Farm Insurance Engineering, Inc. Eugene Harbour Principal 99ss This report is exclusively for the use of the client indicated above and shall not be reproduced in full without wdtten approval of HBC Engineer