Loading...
CF-Coppell Rd SC-LR020130 (3)Hooper Engineering Laboratories, Inc. Construction Materials Testing REPORT OF CONCRETE TESTS`,`` .... JOB NO.: 01.1054 CLIENT: .' Texas Unified Constructors, In~c. *~ DATE: 30 January 2002 PROJEC'I~. Field Service Offices & Maint. Fac., Coppell SUPPLIER: Lattimore LOCATION OF POUR SET 1: Plinths: (9) (~ service center bldg., (5) between D12 and D13 line, (4) D line between service center bldg. and utility bldg. LOCATION OF POUR SET 2: SAMPLE DATA: SET 1 Truck No. 959 Ticket No. 7113335 Time Batched 11:57am Time Sampled 12:45pm Concrete Temp. IASTM C1064) 66°F Air Content (ASTM C231) Unit Weight (ASTM C138) SET 2 MIX NO. 54 Cement Flyash Sand iR. 1.0 in. Water Admix #1 Admix #2 AEA COMPRESSIVE STRENGTH TESTS (ASTM C39) (Standard 6 inch x 12 inch cylinder) Cylinder Slump Age Test Total Load Compressive Required Number Inches Days Date Pounds Strength 28-Day (ASTM C143) psi Strength 108 6.00 ~ 02/20/02 109 6.00 28 03/13/02 110 6.00 28 03/13/02 116,900 28-Day Average 414O 3000 TECHNICIAN: DISTRIBUTION: CBC (12:00 Noon-2:00pm) (3) City of Coppell (1) Vidaud & Associates (1) Doyle Engineering Group (1) Texas Unified Constructors, Inc. 2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148