Amberpoint BP-LR020211WATER INJECTION OBSERVATION
Date of Service:
Client No.:
Client:
Location:
Procedure:
02/11/02
3181
Transwestern Commercial Services
5001 Spring Valley Rd, Suite 600 W
Dallas, TX 75244
Report No.:
Project No.:
Project:
94021029.0047
94021029
Amberpoint Building No. 1
Amberpoint Bus. Pk @ Coppell
Coppell, Texas
Building Pad
General Contractor: Hill & Wilkinson
Injector: Jowell
On this date, a representative of HBC Engineering, Inc. observed the injection of water at this
site. During the injection process, the following observations were recorded.
Pass No.: 1st No. of Probes: 4 Probe Length: 12 feet
OBSERVATION
SPECIFICATION Yes No N/A
Suffactant added to each load. X
Injection pressure 50 to 200 psi at manifold. X
Injection downward in 18 inch intervals. X
Total depth of injection was 7 feet. X
Spacing of injection was 5 feet maximum. X
In, iection to refusal at each location. X
Comments: Jowell was unable to start injecting until 1:00 p.m. due to equipment problems.
Technician: S. Campbell
Report Distribution:
(l) Transwestem Commercial Services
(1) O'Brien & Associates, thc.
(1) TectmiStructures. Inc.
(1) City of Coppell - Constr. hasp.
(1) City of Coppell - Bldg. hasp.
(I) Hill & Wilkinson, Ltd.
(1) Halff Associates
(1) State Farm Insurance