Loading...
CF-Coppell Rd SC-LR020306Hooper Engineering Laboratories, Inc. Construction Materials Testing REINFORCING STEEL PLACEMENT INSPECTION CLIENT: Texas Unified Constructors, Inc. DATE: 6 March 2002 PROJECT: Field Service Offices & Maintenance Facility JOB NO. 01.1054 Coppell, TX TIME: 2.5 hours AREA INSPECTED: DATE OF INSPECTION: DEFICIENCIES NOTED: Slab on cartons, service cener building, lines A to G and 0.1 to 7.8 3/6/02 (10:00am-11:30am, 2;00pm-3:00pm) CORRECTIONS NUMBER LOCATION/ITEM DESCRIPTION OBSERVED 1 Top bars at perimeter incomplete. Yes 2 Bottom bars at perimeter too high. Yes TECHNICIAN: DISTRIBUTION: MFM (3) City of Coppell (1) Vidaud & Associates (1) Doyle Engineering Group (1) Texas Unified Constructors, Inc. 2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148 Hooper Engineering Laboratories, Inc. Construction Materials Testing REPORT OF SOIL GRADATIONS CLIENT: Texas Unified Constructors, Inc. DATE: 6 March 2002 PROJECT: Field Service Offices & Maintenance Fac. JOB NO.: 01.1054 Coppell, TX Taken by representative of Hooper Engineering Laboratories, Inc. on 3/6/02. SAMPLES: 5) 6) 7) LOCATION Pavinq Subqrade 40' south of central utility storage building 70' south of southeast corner of service center 80' south of southwest corner of service center PERCENT PASSING NO. 4 SIEVE % 60.2 66,3 70.1 SPECIFICATION REQUIREMENTS % 60 + NOTE: 100% of all tested material passed the 1-3/4" sieve. TECHNICIAN: DISTRIBUTION: MFM (3) City of Coppell (1) Vidaud & Associates (1) Doyle Engineering Group (1) Texas Unified Constructors, Inc. 2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148 Hooper Engineering Laboratories, Inc. 2870 Walnut Hill Lane Dallas , Texaa 75229 (214) 351.6418 Client: Texas Unified Constructors, Inc. Date: 5 March 20.02 Project: Field Service Offices & Maintenance Job No: 01.1054 Fac., Co~]~ell, TX ~Boil Deecription: Lime Stabilized Suhgrade Grey Silty Clay 'with Lime Maximum Deneity : 96.0 pcf Optimum Moiature : 23.0% Liquid Limit : 31.3 Plasticity Index : 8.1 Distribution: (3) City of Coppell (1) Vidaud & Associates (1) Doyle Engineering Group (1) Texas Unified Constructors, 0 120 0 0 110 100 90 th 80 Thc. MOISTURE-DENSITY RELATIONSHIPASTM D698 i111111111~1 15 25 35 Moisture Content - percent