ST0001-LR020312RoneEngineers 8908 Ambassador Row Dallas, Texas 752474510 (214) 630-9745 (214) 630-9819 (fax) CONCRETE COMPRESSIVE STRENGTH TEST Client: City of Coppcll Report No.: 143433 Attn: Ms. Susan Taylor - Engineering Dept Project No.: 015729 PO Box 478 Date of Service: 02/11/2002  Report Date: 03/12/2002 Service~ Obtain sam IE.l;~h concrete at the placement locations, perform required field testing, cast compressive strength samples and bring ~to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUMP0~: AIR(%): TEST METHOD: CONTRACTOR: Infrastructure Services, Inc. CONCRETE SUPPLIER: Lattimore PLANT: 3 SPECIFICATION REQUIREMENTS 3000 psi ~ 28 Days 3% - 5% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 MIX DESIGN LD.: 42 PLACEMENT DATE: 02/11/2002 WEATHER CONDITIONS: CleflT TIME SAMPLED: 10:45am BATCHTIME: 10:06am TEMPERATURE (F) - AIR 46 F CONCRETE: 51 F T~UCK NO: 819 TIC~T NO: 3140259 AIR CONTENT (%): 4.2 UNIT WEIGHT (pc0: NA OVERALL PLACEMENT LOCATION: Paving - northbound left turn lane 90'-190' SAMPLE LOCATION: REPORT OF TESTS 20'-30' west of east curb and 130' north of start of left turn lane Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE 1 1 3.0 02/18/2002 7 111890 3960 ' Unbonded Cap 1 2 3.0 02/18/2002 7 114960 4070 Unbonded Cap Average 4020 1 3 3.0 03/11/2002 28 138630 4900 Unbonded Cap 1 4 3.0 03/11/2002 28 135355 4790 Unbonded Cap Average 4850 1 5 Hold LIMITATIONS: Thc test results presented herein were prepared based upon the epecifi¢ samples Pr°vided f°r testing' We assume no responsibility for variation in qualiiy (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of thc clients to whom they are addressed and shall not be reproduced except in full without the wri~en approval of Rone Engineers, Inc. 01DK Page 1 of 2 Report No.: 143433 R°ne£ngineers Project No.: 015729 Client: City of Coppell CYLINOER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH ' SET NO. (inches) T~STED (days) Obs. force) (psi) F~URE ~PE Water added at site: 10 9allons Technician: Dan Gammon Started: 9:00am Finished: l:00pm Report Distribution: /// (1) City of Coppoll (1) City of Coppell (1) City of Coppell (1) Schrickel, Rollins & Assoc., Inc. (1) City of Coppoll Proj~ (1) Inflastmcturc Services, Inc. y Stark t Manager LIMITATIONS: The test r~sults presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other featur~ of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the wxitten approval of Rone Engineers, Inc. 01DK Page 2 of 2