Loading...
Amberpoint BP-LR020225WATER INJECTION OBSERVATION ENGINEERING, INC. Date of Service: 02/25/02 Report No.: Client No.: 3181 Project No.: Client: Transwestern Commercial Services Project: 5001 Spring Valley Rd, Suite 600 W Dallas, TX 75244 Location: Building Pad - see attached sketch General Contractor: Injector: 94021029.0072 94021029 Amberpoint Building No. 1 Amberpoint Bus. Pk @ Coppell Coppell, Texas Hill & Wilkinson Jowell Procedure: On this date, a representative of HBC Engineering, Inc. observed the injection of water at this site. During the injection process, the following observations were recorded. Pass No.: 3rd No. of Probes: 4 Probe Length: 12 feet OBSERVATION SPECIFICATION Yes No N/A Surfactant added to each load. X Injection pressure 50 to 200 psi at manifold. X Injection downward in 18 inch intervals. X Total depth of injection was 10 feet. X Spacing of injection was 5 feet maximum. X Injection to refusal at each location. X Comments: Technician: S. Campbell Report Distribution: (l) Transwestem Commercial Services (I) O'Brien & Associates, Inc. ( I ) TechniStructures, Inc. (1) City of Coppell - Constr. lnsp. (1) City of Coppell - Bldg. lnsp (1) Hill & Wilkinson Ltd ( I ) Halff Associates (1) State Farm Insurance Engineering, Inc. Eugene Harbour Principal 99ss This repod is exclusively for the use of the client indicated above and shall not be reproduced in full without written approval of HBC Engineer