Loading...
ST0001-LR020320RoneEngineers 8908 Ambassador Row Dallas, Texas 75247-4510 (214) 630-9745 (214) 630-9819 (fax) CONCRETE COMPRESSIVE STRENGTH TEST Client: City of Coppell At'm: Ms. Susan Taylor - Engineering Dept PO Box 478 Coppell TX 75109 Report No.: 144160 Project No.: 015729 Date of Service: 02/19/2002 Report Date: 03/20/2002 Project: Services: Creekview Drive and Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordanen with applicable standards. PROJECT DATA STRENGTH: SLUMP (in): AIR (%): TEST METHOD: corcrRACTOR: Infrastructure Services, Inc. CONCRETE SUPPLIER: Lattimore PLANT: 6 SPECIFICATION REQUIREMENTS 4000 psi ~ 28 Days 3" - 5" 4% - 6% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 MIX DESIGN I.D.: 42 PLACEMENT OA~: 02/19/2002 WEATHER CONDITIONS: Partly cloudy TIME SAMPLED: 2:20pm BATCH TIME: 1:13pm TEMPERATURE (lq') - AIR 61 F CONCRETE: 60 F TRUC~rNO: 753 TICHETNO: 6169303 AIR CONTENT (%): 3.5 UNIT WEIGHT (PC0: NA OVERALL PLACEMENT LOCATION: Freeport Parkway paving SAMPLE LOCATION: Station 31+50 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) CYLINDER MEASURED MAXIMUM COMPRESSIVE MARBLED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE 4.0 02/22/2002 3 84525 2990 Unbonded Cap 4.0 02/26/2002 7 112710 3990 Unbonded Cap 4.0 03/05/2002 14 117240 4150 Unbonded Cap 4.0 03/19/2002 ~8) 131475 ~"~0) Unbonded Cap Hold LIMITATIONS: The test results p~sented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in qualiW (composition, appearance, performance, e~.) or any other feature of similar subject mattar provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Inc. 01DK Page 1 of 2 Report No.: 144160 Project No.: 015729 Client: City of Coppell CYLINDER MARKED SET NO. MEASURED SLUMP Onch~s) DATE TESTED AGE (days) RoneEngineers MAXIMUM COMPRESSIVE LOAD STRENGTH FRACTURE Obs. force) (psi) TYPE Water added at site: 5 gallons Technician: Todd Jonas Report Distribution: (1) City of Coppell (1) City of Copp¢ll (I) City of Copp¢ll (1) Infrastructure Services, Inc. Started: 12:00pm (1) City of Copp¢ll (1) $¢hrickel, Rollins & Assoc., Inc. Finished: 3:30pm Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subjcet matter provided by persons or conditions over which we have no control. Our letters and repolts are for the exclusive use of thc clients to whom they are addressed and shall not be reproduced cxocpt in full without the wriRen approval of Rone Engineers, Inc. 01DK Page 2 of 2