Amberpoint BP-LR020311WATER INJECTION OBSERVATION Date of Service: Client No.: Client: 03/11/02 3181 Transwestem Commercial Services 5001 Spring Valley Rd, Suite 600 W Dallas, TX 75244 Report No.: Project No.: Project: 94021029.0119 94021029 Amberpoint Building No. 1 Amberpoint Bus. Pk. ~ Coppell Coppell, Texas Location: Building Pad - see attached sketch General Contractor: Hill & Wilkinson Injector: Jowell Procedure: On this date, a representative of HBC Engineering, Inc. observed the injection of water at this site. During the injection process, the following observations were recorded. Pass No.: 7th No. of Probes: 4 Probe Length: 12 feet OBSERVATION SPECIFICATION Yes No NIA Surfactant added to each load. X Injection pressure 50 to 200 psi at manifold. X Injection downward in 18 inch intervals. X Total depth of injection was 7 feet. X Spacing of injection was 5 feet maximum. X Iniection to refusal at each location. X Commen~: Technician: K. Douglas Report Distribution: (1) Transwcstcm Commercial Services (1) O'Brien & Associates, Inc. (1) T¢chniStructures, Inc. (1) City of Coppell - Constr. lnsp. (1) City of Coppell - Bldg. Insp. (1) Hill & Wilkinson, Ltd. (1) HalffAssociates (1) State Farm Insurance I-~ Engineering, Inc. Eugene Harbour Principal 99ss This report is exclusively for the use of the client indicated at:ove and shall not be reproduced in full without written approval of HBC Engineer 'B' ;II-C;Z. ® ® © ® @ _I .I WATER INJECTION OBSERVATION ENGINEERING, INC. Date of Service: Client No.: Client: 03/09/02 3181 Transwestem Commercial Services 5001 Spring Valley Rd, Suite 600 W Dallas, TX 75244 Report No.: Project No.: Project: 94021029.0115 94021029 Amberpoint Building No. i Amberpoint Bus. Pk. @ Coppell Coppell, Texas Location: Building Pad - see attached sketch General Contractor: Hill & Wilkinson Injector: Jowell Procedure: On this date, a representative of HBC Engineering, Inc. observed the injection of water at this site. During the injection process, the following observations were recorded. Pass No.: 7th No. of Probes: 4 Probe Length: 12 feet OBSERVATION SPECIFICATION Yes No N/A Surfactant added to each load. X Injection pressure 50 to 200 psi at manifold. X Injection downward in 18 inch intervals. X Total depth of injection was 7 feet. X Spacing of injection was 5 feet maximum. X Injection to refusal at each location. X Comments: Technician: S. Campbell Report Distribution: (1) Transwestem Commercial Services (I) O'Brien & Associates, Inc. ( I ) TechniStructures, Inc. (I) City of Coppoll - Constr. Insp. (I) City of Coppell - Bldg Insp (1) Hill & Wilkinson, Ltd ( I ) Halff Associates (I) State Farm Insurance H~C Engineering, Inc. Eugene H bou~r Principal 99ss This report is excluslvely for the use of the client indicated above and shall not be reproduced in full without wdtten approval of HBC Engineer 0.0, ..mO