Amberpoint BP-LR020307 (2)WATER INJECTION OBSERVATION
Date of Service:
Client No.:
Client:
Location:
Procedure:
03/12/02
3181
Transwestem Commercial Services
5001 Spring Valley Rd, Suite 600 W
Dallas, TX 75244
Report No.:
Project No.:
Project:
94021029.0123
94021029
Amberpoint Building No.1
Amberpoint Bus. Pk. ~ Coppell
Coppell, Texas
Building Pad - see attached sketch General Contractor: Hill & Wilkinson
injector: Jowell
On this date, a representative of HBC Engineering, Inc. observed the injection of water at this
site. During the injection process, the following observations were recorded.
Pass No.: 7th No. of Probes: 4 Probe Length: 12 feet
OBSERVATION
SPECIFICATION Yes No N/A
Surfactant added to each load. X
Injection pressure 50 to 200 psi at manifold. X
Injection downward in 18 inch intervals. X
Total depth of injection was 10 feet. X
Spacing of injection was 5 feet maximum. X
Injection to refusal at each location. X
Commen~:
Technician: S. Campbell
Report Distribution:
(1) Tramwcstem Commercial Services
(1) O'Bricn &Associatcs, Inc.
(1) TcchniStmcturcs, Inc.
(1) City of Coppell - Constr. Insp.
(1) City of Copp¢ll - Bldg. Insp.
(1) Hill & Wilkinson, Ltd.
(1) HalffAs$ociates
(1) State Farm Insurance
~ Engineering, Inc.
Eugene Harbour
Principal
99ss This report is exclusively for the use of the client indicated above and shall not be mpreduced in full without wdttefl approval of HBC Engineer
'~0
WATER INJECTION OBSERVATION
ENGINEERING, 1NC.
Date of Service:
Client No.:
Client:
Location:
Procedure:
O3/07/O2
3181
Transwestem Commercial Services
5001 Spring Valley Rd. Suite 600 W
Dallas, TX 75244
Report No.:
Project No.:
Project:
94021029.0109
94021029
Amberpoint Building No. 1
Amberpoint Bus. Pk. @ Coppell
Coppell, Texas
Building Pad - see attched sketch General Contractor:
Injector:
Hill & Wilkinson
Jowell
On this date, a representative of HBC Engineering, Inc. observed the injection of water at this
site. During the injection process, the following observations were recorded.
Pass No.: 6th No. of Probes: 4 Probe Length: 10 feet
OBSERVATION
SPECIFICATION Yes No N/A
Surfactant added to each load. X
Injection pressure 50 to 200 psi at manifold. X
Injection downward in 18 inch intervals. X
Total depth of injection was 10 feet. X
Spacing of injection was 5 feet maximum. X
Iniection to refusal at each location. X
Comments: On this date, four injection rigs were working this area. Surfactant was supposed to be added two
(2) times a day. Jowell was also instructed by Brian, Hill & Wilkinson's superintendent, to let one of
HBC's technician witness the addition. The surfactant was never added on this date.
Technician: S. Campbell
Report Distribution:
( l )Transwestern Commercial Services
(1) O'Brien & Associates, Inc.
( 1 ) TechniStructures. [nc.
(1) City of Coppell - Constr. [nsp.
(I) City of Coppell - Bldg. Insp.
(I) Hill & Wilkinson, Ltd.
( 1 ) Halff Associates
(1) State Farm Insurance
~ Engineering, Inc.
Eugene arb~our
Principal