ST0001-LR020320 (2)RoneEngineers 8908 Ambassador Row Dallas, Texas 75247-4510 (214) 630-9745 (214) 630-9819 (fax) CONCRETE COMPRESSIVE STRENGTH TEST Client: City of Coppell Arm: Ms. Susan Taylor - Engineering Dept PO Box 478 Coppell TX 75109 Report No.: 144160 Project No.: 015729 Date of Service: 02/19/2002 Report Date: 03/20/2002 Project: Services: Creekview Drive and Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUMP (in): AIR (%): TEST METHOD: coNTRActoR: Infrastructure Services, Inc. CONCRETE SUPPLIER: Lattimore PLANT: 6 SPECIFICATION REQUIREMENTS 4000 psi ~ 28 Days 3" - 5" 4% - 6% ASTM C-172 ASTIvl C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTIVl C-138 ASTM C-39 MIX DESIGN I.D.: 42 eLACEMENT DA~: 02/19/2002 WEATHER CONDITIONS: Partly cloudy TIME SAMPLED: 2:20pm BATCH TIME: 1:13pm TEMPERATURE (F) - AIR 61 E CONCRETE: 60 r TRUCK NO: 753 TICKET NO: 6169303 AIR CONTENT (%): 3.5 UNIT WEIGHT (PC0: NA OVERALL PLACEMENT LOCATION: Fr~port Parkway paving SAMPLE LOCATION: Station 31+50 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) Obs. force) (psi) TYPE i 1 4.0 02/22/2002 3 84525 2990 Unbonded Cap 1 2 4.0 02/26/2002 7 112710 3990 Unbonded Cap 1 3 4.0 03/05/2002 14 117240 4150 Unbonded Cap 1 4 4.0 03/19/2002 28 131475 4650 Unbonded Cap 1 5 Hold LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no respo~sinillty for variation in quality (composition, appearance, perfonnaace, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineem, Inc. 01DK Page 1 of 2 Report No.: 144160 Project No.: 015729 CYLINDER MARKED SET NO. Client: City of Coppell MEASURED SLUMP DATE (inches) TESTED AGE (days) RoneEngineers MAXIMUM COMPRESSIVE LOAD STRENGTH FRACTURE (lbs. force) (psi) TYPE Water added at site: Technician: Todd Jonas Report Distribution: (1) City of Copp¢ll (1) City of Coppcll (1) City of Coppell (I) In frash'ucture Services, Inc. 5 gallons Started: 12:00pm (1) City of Coppell (1) Schrickel, Rollins & Assoc., Inc. Finished: 3:30pm Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in Inll without the written approval of Rone Engineers, Inc. 01DK Page 2 of 2