Northpoint Dr-LR020328CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94021061.0013
Service Date: March 26, 2002
8901 Carpenter F~%,., Suite #100
Dallas, Texas 75247
(214) 630-1010
Client: Transwestem Commercial Services
Attn: Jim Gaspard
5001 Spring Valley Rd Suite 600W
Dallas TX 75244
Report Date: March 28, 2002
Project: Northpoint Drive &
Associated Utilities
Coppell, Texas
Project Number: 940~1061
Material Information
Specified Strength:
Batch Time: N/A
Supplier: N/A
Truck No: N/A
Mix I.D. No.: N/A
Plant: N/A
Field Test Data
Test
Result
Slump, inches: N/A
Air Content, %: N/A
Concrete Temperature,O F: N/A
Ambient Temperature, o F: N/A
Plastic Unit Weight, pcf:
Laboratory Test Data
Ticket No: N/A
Sample Information
sample Time: N/A Date Cast: March 8, 2002
Technician: Contractor Made
Weather Conditions: N/A
Accumulative Yards: N/A
Placement Method: N/A
Sample Locations: MH Sta. 0+69.17 Line C
Placement Location: See page 1
Specification
Test Method
N/A ASTM C-143
N/A
ASTM C1064
ASTM C-1064
Age at Maximum Compressive
Set Specimen Diameter Area Date Test Load Strength
No. ID (inches) .(sq. inches) Tested (days) (lbs) (psi)
2 1 6.00 28.27 03/27/2002 19 132,270 4,680
2 2 6.00 28.27 03/27/2002 19 121,570 4,300
Average 4,490
2 3 04/05/2002 28
2 4 04/05/2002 28
Services - Pick up test cylinders cast by others and return them to the laboratory for curing and testing.
Technician: Brad Rengstorff
Report Distribution:
(1) Transwestem Commercial Sen/ices
(1) Glenn Thurman Inc
(1) Halff Associates
(1) City of Coppell - Engineering
(1) City of Coppell - Bldg Insp
(1) State Farm Insurance
(1) Moss Construction
Reviewed by:
HBC Engi.~
Eugene Harbour
Principal
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94021061.0015
Service Date: March 26, 2002
8901 Carpenter Frv~y., Suite #1(30
Dallas, Texas 75247
(214) 630-1010
Client: Transwestern Commercial Services
Attn: Jim Gaspard
5001 Spring Valley Rd Suite 600W
Dallas TX 75244
Report Date: March 28, 2002
Project: Northpoint Drive &
Associated Utilities
Coppell, Texas
Project Number: 94021061
Material Information
Specified Strength:
Batch Time: N/A
Supplier: N/A
Truck No: N/A
Mix I.D. No.: N/A
Plant: N/A
Field Test Data
Test
Ticket No: N/A
Sample Information
Sample Time: N/A Date Cast: March 12, 2002
Technician: Contractor Made
Weather Conditions: N/A
Placement Method: N/A
Sample Locations: MH Sta. 7+26.58 Line C
Placement Location: Sanitary Sewer
Result Specification Test Method
Slump, inches: N/A N/A ASTM C-143
Air Content, %: N/A N/A
Concrete Temperature,° F: N/A ASTM C1064
Ambient Temperature, o F: N/A ASTM C-1064
Plastic Unit Weight, pcf:
Laboratory Test Data
Age at Maximum Compressive
Set Specimen Diameter Area Date Test Load Strength
No. ID (inches) (sq. inches) Tested (days) (lbs) (psi)
1 1 6.00 28.27 03/27/2002 15 129,810 4,590
1 2 6.00 28.27 03/27/2002 15 135,110 4,780
Average 4,690
1 3 04/09/2002 28
1 4 04~09~2002 28
Services - Pick up test cylinders cast by others and return them to the laboratory for curing and testing.
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials
CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94021061.0015
Service Date: Mamh 26, 2002
8901 Carpenter Frwy., Suite #100
Dallas, Texas 75247
(214) 630-1010
Client: Transwestem Commercial Services
Attn: Jim Gaspard
5001 Spring Valley Rd Suite 600W
Dallas TX 75244
Report Date: March 28, 2002
Project: Northpoint Drive &
Associated Utilities
Coppell, Texas
Project Number: .94021061
Material Information
Specified Strength:
Batch Time: N/A
Supplier: N/A
Truck No: N/A
Mix I.D. No.: N/A
Plant: N/A
Field Test Data
Test
Slump, inches:
Air Content, %:
Concrete Temperature,O F:
Ambient Temperature, e F:
Plastic Unit Weight, pcf:
Laboratory Test Data
Ticket No: N/A
Sample Information
sample Time: N/A Date Cast: March 12, 2002
Technician: Contractor Made
Weather Conditions: N/A
Accumulative Yards: N/A
Placement Method: N/A
Sample Locations: N/A
Placement Location: See page 1
Result Specification Test Method
N/A N/A ASTM C-143
N/A N/A
N/A ASTM C1064
N/A ASTM C-1064
Set Specimen Diameter Area Date
No. ID (inches) (.sq. inches) Tested
2 I 6.00 28.27 03/27/2002 15 128,530 4,550
2 2 6.00 28.27 03/27/2002 15 125,740 4,450
Average 4,500
2 3 04/09/2002 28
2 4 04/09/2002 28
Age at Maximum Compressive
Test Load Strength
(days) (lbs) (psi)
Services - Pick up test cylinders cast by others and return them to the laboratory for curing and testing.
Technician: Brad Rengstorff
Report Distribution:
(1) Transwestern Commercial Services
(1) Glenn Thurman Inc
(1) Halff Associates
(1) City of Coppell - Engineering
(1) City of Coppell - Bldg Insp
(1) State Farm Insurance
(1) Moss Construction
Reviewed by:
HBC Enginee~
Eugene Harbeur
Principal
The tests were pedorrned in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94021061.0016
Service Date: March 26, 2002
8901 Carpenter Fn,vy., Suite #100
Dallas, Texas 75247
(214) 630-1010
Client: Transwestem Commercial Services
Attn: Jim Gaspard
5001 Spring Valley Rd Suite 600W
Dallas TX 75244
Report Date: March 28, 2002
Project: Northpoint Drive &
Associated Utilities
Coppell, Texas
Project Number: 94021061.
Material Information
Specified Strength:
Batch Time: N/A
Supplier: N/A
Truck No: N/A
Mix I.D. No.: N/A
Plant: N/A
Field Test Data
Test
Ticket No: N/A
Slump, inches:
Air Content, %:
Concrete Temperature,° F:
Ambient Temperature, o F:
Plastic Unit Weight, pcf:
Sample Information
sample Time: N/A Date Cast: March 14, 2002
Technician: Contractor Made
Weather Conditions: N/A
Accumulative Yards: N/A
Placement Method: N/A
Sample Locations: MH Sta. 12+51.39 Line C
Placement Location: Sanitary Sewer
Result Specification Test Method
N/A N/A ASTM C-143
N/A N/A
N/A ASTM C1064
N/A ASTM C-1064
Laboratory Test Data Age at Maximum Compressive
Set Specimen Diameter Area Date Test Load Strength
No. ID (inches) (sq. inches) Tested (days) (lbs) (psi)
1 1 6.00 28.27 03/27/2002 '13 101,700 3,600
1 2 6.00 28.27 03/27/2002 13 100,700 3,560
Average 3,580
1 3 04/11/2002 28
1 4 04/11/2002 28
Services - Pick up test cylinders cast by others and return them to the laboratory for curing and testing.
Technician: Brad Rengstorff
Report Distribution:
(1) Transwestern Commercial Services
(t) Glenn Thurman Inc
(1) Halff Associates
(1) City of Coppell - Engineering
(1) City of Coppell - eldg Insp
(1) State Farm Insurance
(1) Moss Construction
Reviewed by:
HBC Engine-
Eugene Ha~o/~r
Principal
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
FIELD DENSITY TESTING
Report Number: 94021061.0006
Service Date: Mamh 13, 2002
Client: Transwestem Commercial Services
Attn: Jim Gaspard
5001 Spring Valley Rd Suite 600W
Dallas TX 75244
Repo~l~ll~'!'-March 27, 20~
Proj~
Coppell, Texas
Project Number: 94021061
8901 Carpenter Fn~y., Suite #100
Dallas, Texas 75247
(214) 630-1010
Material Information Lab Test Data Proiect Requirements
Optimum Max. Lab Water
Water Dry Unit Content Minimum Dry
Material Laboratory Content Weight Range Unit Weight
No. Test Method Description and Classification (%) (pcf) (%) (% compaction)
1. 210610004 ASTM D 698 Reddish brown silty clayey sand 11.8 117.0 -1/+3 95
Field Test Data Probe Water Dry Unit Dry Unit
Test LiftJ Mat. Depth Content Weight Weight
No. Test Location Elevation No. (inches) (%) (pct') (% compaction)
Sanitary Sewer, Line C
13 Sra. 4+75 6' BEG 1 6 10.8/112.6 96
14 Sta. 5+50 4' BEG 1 6 11.4/ 113.1 97
15 Sta. 6+00 7' BEG I 6 11.7~, 113.4 97
16 Sta. 7+00 3' BEG I 6 12.6 ~ 112.3 96
Datum: BEG = below existing grade
Comments:
Test results on this report meet project specification,
Services o Perform in-place density and moisture content tests to determine degree of compaction and material moisture
condition.
Field Test Method:ASTM D2922, ASTM D3017
Gauge ID:
Field Results Reported To: Contractor/Moss
Technician: Brad Rengstorff
Report Distribution:
(1) Transwestern Commemial Services
(1) Glenn Thurman Inc
( 1 ) Haitf Associates
(1) City of Coppell - Engineering
(1) City of Coppell - Bldg Insp
(1) State Farm Insurance
(1) Moss Construction
Reviewed by:
HBC Engin~
Eugene Harbour
Principal
The tests were pedormed in general accordance with applicable ASTM, MSHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
FIELD DENSITY TESTING
Report Number: 94021061.0008
Service Date: Mamh 15, 2002
Client: Transwestern Commercial Services
Attn: Jim Gaspard
5001 Spring Valley Rd Suite 600W
Dallas TX 75244
Proj~: Northpoint Drive &
ciated Utilities
Coppell, Texas
Project Number: 9402'1061
8901 Carpenter Fn~y., Suite #100
Dallas, Texas 75247
(214) 630-1010
Material Information Lab Test Data Proiect Requirements
Optimum Max. Lab Water
Water Dry Unit Content Minimum Dry
Matedal Laboratory Content Weight Range °Unit We~,ig ht
No. Test Method Description and Classification (%) (pcf) (%) (yo ,~'~"c~n)
1. 210610004 ASTM D 698 Reddish brown silty clayey sand 11.8 117.0 -11+3 9~r 95
2. 210290004 ASTM D-698 Dk brown clay 22.4 99.9 -1/+3
Field Test Data Probe Water Dry Unit Dry Unit
Test Lift/ Mat. Depth Content Weight Weight
No. Test Location Elevation No. (inches) (%) (pcf) (% compaction)
Sanitary Sewer, Line C ~
21 Sra. 12+00 6' BEG 1 6 12.2 114.3 ~98
22 Sta. 13+00 5' BEG 1 6 13.1 111.9 96
23 Sta. 14+00 2' BEG 1 6 12.8 112.6 96
Water Line, Line A
24 Sra. 1+10 1st 2 6 24.2 96.6 97
25 Sta. 1+10 2nd/Final 2 6 23.9 97.2 97
26 Sta. 2+25 1st 2 6 23.7 96,3 96
27 Sta, 2+25 2nd/Final 2 6 22.8 99.8
Datum: BEG = below existing grade
Comments:
Test results on this report meet project specification.
Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture
condition.
Field Test Method:ASTM D2922, ASTM D3017
Gauge ID:
Field Results Reported To: ContractodMoss
Technician: Brad Rengstorff
Report Distribution:
(1) Transwestem Commercial Services
(1) Glenn Thurn~an Inc
( 1 ) Halff Associates
(1) City of Coppell - Engineering
(1) City of Coppell - BIdg Insp
(1) State Fam~ Insurance
(1) Moss Construction
Reviewed by:
HBC En~J~
Eugene Harbour
Principal
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above aod shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.