Amberpoint BP-LR020408CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94021029.0165
Service Date: March 29, 2002
ENGINEE I~JNG
8901 Carpenter Frwy,, Suite #100
Dallas, Texas 75247
(214) 630-1010
Client: Transwestern Commercial Services
Attn: Jim Gaspard
5001 Spring Valley Rd. Suite 600W
Dallas TX 75244
Report Date: April 08, 2002
Project: Amberpoint Building No. 1
Amberpoint Bus. Pk. @ Coppell
Coppell, Texas
Project Number: 94021029
Material Information
Specified Strength: 3000 psi @ 28 Days
Batch Time: 10:58am Plant: 16
Supplier: Potter
Truck No: 113
Mix I.D. No.: 9337
Ticket No: 612481
Sample Information
sample Time: 11:1 lam Date Cast: March 29, 2002
Technician: Gerry Graham
Weather Conditions: Fair, cloudy
Placement Method: Direct Discharge
Sample Locations: Q/9 and Q/9.5
Placement Location: Piers
Field Test Data
Test Result Specification Test Method
Slump, inches: 6.25 5-7 ASTM C-143
Air Content, %: N/A
Concrete Temperature, o F: 71 ASTM C1064
Ambient Temperature, o F: 75 ASTM C-1064
Plastic Unit Weight, pcf:
Laboratory Test Data
Age at
Maximum Compressive
Set Specimen Diameter Area Date Test Load Strength
No. ID (inches) (sq. inches) Tested (days) (lbs) (psi)
I 1 6.00 28.27 04/05/2002 7 110,030 3,890
1 2 6.00 28.27 04/05/2002 7 113,750 4,020
Average 3,960
1 3 04/26/2002 28
1 4 04/26/2002 28
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
Technician: Gerry Graham
Report Distribution:
(1) Transwestern Commercial Services
(1) O'Brien & Associates Inc
(1) TechniStructures Inc
(1) City of Coppel[ - Constr Insp
(1) City of Coppell - Bldg Insp
(1) Hill & Wilkinson Ltd
(1) Halff Associates
(1) State Farm Insurance
Reviewed by:
Principal
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the wdtten approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 1 O~-LL~"~