Amberpoint BP-LR020412CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0181 Service Date: April 4, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 Report Date: April 12, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 9:10am Supplier: Potter Truck No: 108 Mix I.D. No.: 9349 Plant: 16 Ticket No: 612581 Sample Information Sample Time: 9:35am Date Cast: April 4, 2002 Technician: Marvin Arandia Weather Conditions: Cloudy Accumulative Yards: 600 Placement Method: Direct Discharge Sample Locations: M.3, 9.8 Placement Location: Slab lines 9-11, C-N Field Test Data Test Result Specification Test Method Slump, inches: 4.00 ASTM C-143 Air Content, %: Concrete Temperature, o F: 60 ASTM C1064 Ambient Temperature, o F: 54 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Set Specimen Diameter Area Date Test No. ID (inches) (sq. inches) Tested (days) 7 1 6.00 28.27 04/11/2002 7 7 2 6.00 28.27 04/11/2002 7 Average 7 3 05/02/2002 28 7 4 05/02/2002 28 Maximum Compressive Load Strength (lbs) (psi) 155,630 5,500 151,280 5,350 5,430 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Marvin Arandia Report Distribution: (1) Transwestern Commercial Services (1) O'Brien & Associates Inc (1) TechniStructures Inc (1) City of Copper - Constr Insp (1) City of Coppell - Bldg [nsp (1) Hill & Wilkinson Ltd (1) Halff Associates (1) State Farm Insurance Reviewed by: HBC Engin~'''~ Eugene Harbour Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. 0~ LLW~0, Page 7 of 7 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0181 Service Date: April 4, 2002 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 ENGINF. ERING 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: April 12, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 8:13am Supplier: Potter Truck No: 102 Mix I.D. No.: 9349 Plant: 16 Ticket No: 612569 Sample Information Sample Time: 8:45am Date Cast: April 4, 2002 Technician: Marvin Arandia Weather Conditions: Cloudy Accumulative Yards: 500 Placement Method: Direct Discharge Sample Locations: L, 9.3 Placement Location: Slab lines (9-11, C-N) Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 5.50 60 53 Set Specimen Diameter Area No. ID (inches)~(sq. inches) 6 1 6.00 28.27 6 2 6.00 28.27 6 3 6 4 Specification Test Method ASTM C-143 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 04/11/2002 7 152,960 5,410 04/11/2002 7 159,110 5,630 Average 5,520 05/02/2002 28 05/02/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 6 of 7 o, LLW~O~ CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0181 Service Date: April 4, 2002 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: April 12, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 6:33am Plant: 16 Supplier: Potter Truck No: 107 Mix I.D. No.: 9349 Ticket No: 612560 Sample Information Sample Time: 7:00am Date Cast: April 4, 2002 Technician: Marvin Arandia Weather Conditions: Cloudy Accumulative Yards: 400 Placement Method: Direct Discharge Sample Locations: J, 10 Placemen( Location: Slab lines 9-11, C-N Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result Specification Test Method 4.00 ASTM C-143 60 ASTM C1064 48 ASTM C-1064 Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 5 1 6.00 28.27 04/11/2002 7 164,510 5,820 5 2 6.00 28.27 04/11/2002 7 169,860 6,010 Average 5,920 5 3 05/02/2002 28 5 4 05/02/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 7 0, ~Lw,.0~ CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0181 Service Date: April 4, 2002 Client: Transwestem Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: April 12, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. (~ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 5:05am Supplier: Potter Truck No: 111 Mix I.D. No.: 9349 Plant: 16 Ticket No: 612549 Sample Information Sample Time: 5:30am Date Cast:April 4, 2002 Technician: Marvin Arandia Weather Conditions: Clear Accumulative Yards: 300 Placement Method: Direct Discharge Sample Locations: 9.2, F.8 Placement Location: Slab lines 9-11, C-N Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result Specification Test Method 5.50 ASTM C-143 60 ASTM Cl 064 48 ASTM C-1064 Set Specimen Diameter Area No. ID (inches) (sq. inches) Age at Date Test Tested (days) 4 I 6.00 28.27 04/11/2002 7 4 2 6.00 28,27 04/11/2002 7 Average 4 3 05/02/2002 28 4 4 05/02/2002 28 Maximum Compressive Load Strength (lbs) (psi) 165,890 5,870 171,270 6,060 5,970 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indidated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical Page 4 of 7 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0181 Service Date: April 4, 2002 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: April 12, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 4:27am Supplier: Potter Truck No: 110 Mix I.D. No.: 9349 Plant: 16 Ticket No: 612541 Sample Information Sample Time: 5:00am Date Cast: April 4, 2002 Technician: Marvin Arandia Weather Conditions: Clear Accumulative Yards: 210 Placement Method: Direct Discharge Sample Locations: 10.4, E Placement Location: Slab lines (9-11, C-0) Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result Specification Test Method 5.50 ASTM C-143 60 ASTM C1064 48 ASTM C-1064 Set Specimen Diameter Area Date No. ID (inches) (.sq. inches) Tested 3 1 6.00 28.27 04/11/2002 7 152,640 5,400 3 2 6.00 28.27 04/11/2002 7 148,300 5,240 Average 5,320 3 3 05/02/2002 28 3 4 05/02/2002 28 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 7 ~ LLW'"~I."~. CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0181 Service Date: April 4, 2002 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: April 12, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 3:30am Supplier: Potter Truck No: 111 Mix I.D. No.: 9349 Plant: 16 Field Test Data Test Ticket No: 612529 Sample Information Sample Time: 4:05am Date Cast:April 4, 2002 Technician: Marvin Arandia Weather Conditions: Clear Accumulative Yards: 100 Placement Method: Direct Discharge Sample Locations: D.3, 10.5 Placement Location: Slab lines 9-11, C-0 Result Specification Test Method 5.75 ASTM C-143 59 ASTM C1064 48 ASTM C-1064 Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratorv Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 2 I 6.00 28.27 04/11/2002 7 160,270 5,670 2 2 6.00 28.27 04/11/2002 7 154,890 5,480 Average 5,580 2 3 05/02/2002 28 2 4 05/02/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical Page 9 of 7 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0181 Service Date: April 4, 2002 ENGINEERING 8901 Carpenter Fnt,,y., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestem Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 Report Date: April 12, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 2:54am Supplier: Potter Truck No: 102 Mix i.D. No.: 9349 Plant: 16 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratorv Test Data Ticket No: 612521 Sample Information Sample Time: 3:25am Date Cast: April 4, 2002 Technician: Marvin Arandia Weather Conditions: Clear Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: 9, C.1 Placement Location: Slab lines (9-11 ,C-0) Result Specification Test Method 6.00 ASTM C-143 60 ASTM C1064 48 ASTM C-1064 Set Specimen Diameter Area Date No. ID (inches) (sq. inches) Tested 1 1 6.00 28.27 04/11/2002 7 154,180 5,450 1 2 6.00 28.27 04/11/2002 7 151,860 5,370 Average 5,410 1 3 05/02/2002 28 1 4 05/02/2002 28 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) Services - Obtain samples of fresh concrete at the placement locations, pedorm required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use cf the client indicated above and shah not be reproduced except in fu~l without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 7 o~ ~w~0~ CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0183 Service Date: April 4, 2002 8901 Carpenter Fn,W., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commemial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 Report Date: April 12, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 3000 psi (~ 28 Days Batch Time: 10:29am Plant: 16 Supplier: Potter Truck No: 103 Mix I.D. No.: 9337 Field Test Data Test Ticket No: 612594 Sample Information Sample Time: 10:37am Date Cast: April 4, 2002 Technician: Gerry Graham Weather Conditions: Fair, cloudy Accumulative Yards: 20 Placement Method: Direct Discharge Sample Locations: B/4, C/4 & D/4 Placement Location: Piers Result Specification Test Method 5.75 5-7 ASTM C-143 N/A 67 ASTM C1064 56 ASTM C-1064 Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 1 6.00 28.27 04/11/2002 7 153,820 5,440 1 2 6.00 28.27 04/11/2002 7 153,470 5,430 Average 5,440 1 3 05/02/2002 28 1 4 05/02/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Gerry Graham Report Distribution: (1) Transwestern Commercial Services (1) O'Brien & Associates Inc (1) TechniStructures Inc (1) City of Coppell - Constr Insp (1) City of Coppell - Bldg Insp (1) Hill & Wilkinson Ltd (1) Halff Associates (1) State Farm Insurance Reviewed by: HBC Eng~ Eugene Harbour Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the wdtten approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials Page 1 of 1 °'~L~°l CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0125 Service Date: March 14, 2002 ENGINEEI~r~ 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 Report Date: April 12, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas 'Project Number: 94021029 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 2:24pm Supplier: LMC Truck No: 834 Mix I.D. No.: 44 Plant: 3 Field Test Data Test Ticket No: 3141890 Sample Information Sample Time: 3:45pm Date Cast: March 14, 2002 Technician: Steve Campbell Weather Conditions: Clear Accumulative Yards: 10 Placement Method: Crane & Bucket Sample Locations: See placement location Placement Location: Manhole Sta. 00+00 Result Specification Test Method 3.25 2.0 Max ASTM C-143 4.1 3-5 ASTM C-231 79 ASTM C1064 78 ASTM C-1064 Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 I 6.00 28.27 03/21/2002 7 109,650 3,880 I 2 6.00 28.27 03/21/2002 7 108,440 3,830 Average 3,860 I 3 6.00 28.27 04/11/2002 28 138,810 4,910 1 4 6.00 28.27 04/11/2002 28 135,240 4,780 Average 4,850 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Steve Campbell Report Distribution: HBC Engine/,/~-- (1) Transwestern Commercial Services (1) City of Coppell- Bldg Insp (// (1) O'Brien & Associates Inc (1) Hill & Wilkinson Ltd Reviewed by: (1) TechniStructures Inc (1) Halff Associates Eugene HaJ~edr (1) City of Coppell - Constr Insp (1) State Farm Insurance Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full w~thout the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 0,.L~,,~0, CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0191 Service Date: April 4, 2002 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: April 12, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. (~ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 4000 psi ~ 28 Days Batch Time: 2:04pm Supplier: LMC Truck No: 757 Mix I.D. No.: 44 Plant: 7 Field Test Data Test Ticket No: 7115188 Sample Information Sample Time: 4:00pm Date Cast: April 4, 2002 Technician: Steve Campbell Weather Conditions: Cloudy Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: See placement location Placement Location: Manhole at NW corner of slab Result Specification Test Method 2.50 3.0 Max ASTM C-143 4.7 3.5-6.5 ASTM C-231 81 ASTM C1064 65 ASTM C-1064 Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 1 6.00 28.27 04/11/2002 7 120,720 4,270 1 2 6.00 28.27 04/11/2002 7 117,770 4,160 Average 4,220 1 3 05/02/2002 28 1 4 05/02/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Steve Campbell Report Distribution: (1) Transwestern Commercial Services (1) O'Brien & Associates Inc (1) TechniStructures Inc (1) City of Coppell - Constr Insp (1) City of Coppell - BIdg Insp (1) Hill & Wilkinson Ltd (1) Halff Associates (1) State Farm Insurance Reviewed by: HBC En~ Eugene Harbour Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shal~ not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. 01 L[W~01 F~ure Key Page 1 of 1