Amberpoint BP-LR020411CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94021029.0180
Service Date: April 3, 2002
Client: Transwestern Commercial Services
Attn: Jim Gaspard
5001 Spring Valley Rd. Suite 600W
Dallas TX 75244
ENGINEERING
8901 Carpenter Frwy., Suite#100
Dallas, Texas 75247
(214) 630-1010
Report Date: April 11,2002
Project: Amberpoint Building No. 1
Amberpoint Bus. Pk. @ Coppell
Coppell, Texas
Project Number: 94021029
Material Information
Specified Strength: 3000 psi @ 28 Days
Batch Time: 9:00am
Supplier: Potter
Truck No: 114
Mix I.D. No.: 9337
Plant: 16
Ticket No: 612511
Sample Information
Sample Time: 9:20am Date Cast: April 3, 2002
Technician: Steve Campbell
Weather Conditions: Clear, windy
Accumulative Yards: 10
Placement Method: Direct Discharge
Sample Locations: Pier D-6
Placement Location: Piers D-6, E-6, F-6
Field Test Data
Test Result Specification Test Method
Slump, inches: 6.50 6-7 ASTM C-143
Air Content, %: None
Concrete Temperature,° F: 62 ASTM C1064
Ambient Temperature, o F: 49 ASTM C-1064
Plastic Unit Weight, pcf:
Laboratorv Test Data Age at Maximum Compressive
Set Specimen Diameter Area Date Test Load Strength
No. ID (inches) (sq. inches) Tested (days) (lbs) (psi)
1 1 6.00 28.27 04/10/2002 7 133,200 4,710
1 2 6.00 28.27 04/10/2002 7 133,560 4,720
Average 4,720
1 3 05/01/2002 28
1 4 05/01/2002 28
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
Technician: Steve Campbell
Report Distribution:
(1) Transwestern Commercial Services
(1) O'Brien & Associates Inc
(1) TechniStructures Inc
(1) City of Coppell - Bldg Insp
(1) Hill & Wilkinson Ltd
(1) Halff Associates
Reviewed by:
HBC Engin~
Eugene Harbour
(1) City of Coppell - Constr Insp (1) State Farm Insurance Principal
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
Page 1 of 1
REPORT OF DRILLED BELLED PIER OBSERVATION
Report Number: 94021029.0179
Service Date: April 3, 2002
8901 Carpenter Frw¥., Suite #100
Dallas, Texas 75247
(214) 630-1010
Client: Transwestem Commercial Services
Attn: Jim Gaspard
5001 Spring Valley Rd. Suite 600W
Dallas TX 75244
Report Date: April 11,2002
Project: Amberpoint Building No. 1
Amberpoint Bus. Pk. @ Coppell
Coppell, Texas
Project Number: 94021029
Services:
Drilled belled pier observation.
On this date, an HBC Engineering technician arrived at the above referenced jobsite as scheduled for
drilled belled pier observation. See the attached sheet(s) for recorded data.
Technician: Steve Campbell //
Report Distribution: HBC Engi~
(1) Transwestern Commercial Services (1) City of Coppell - Bldg Insp
(1) O'Brien & Associates Inc (1) Hill & Wilkinson Ltd Reviewed by:
(1) TechniStructures Inc (1) Halff Associates Eugene Ha,~our
(1) City of Coppell - Constr Insp (1) State Farm Insurance Principal
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 1 ~ ~
<<~
REPORT OF DRILLED BELLED PIER OBSERVATION
Report Number: 94021029.0184
Service Date: April 4, 2002
8901 Carpenter Frwy., Suite #100
Dallas, Texas 75247
(214) 630-1010
Client: Transwestem Commercial Services
Attn: Jim Gaspard
5001 Spring Valley Rd. Suite 600W
Dallas TX 75244
Report Date: April 11,2002
Project: Amberpoint Building No. 1
Amberpoint Bus. Pk. @ Coppell
Coppell, Texas
Project Number: 94021029
Services:
Drilled belled pier observation
On this date, an HBC Engineering technician arrived at the above referenced jobsite as scheduled for
drilled belled pier observation. See the attached sheet(s) for recorded data.
Technician: Steve Campbell
Report Distribution:
(1) Transwestern Commercial Services
(1) O'Brien & Associates Inc
(1) TechniStructures Inc
(1) City of Coppell - Bldg Insp
(1) Hill & Wilkinson Ltd
(1) Halff Associates
Reviewed by:
Eugene Harbour
(1) City of Coppell - Constr Insp (1) State Farm Insurance Principal
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 1