Northpoint Dr-LR020412FIELD DENSITY TESTING
Report Number: 94021061.0022
Service Date: April 3, 2002
Client: Transwestern Commercial Services
Attn: Jim Gaspard
5001 Spring Valley Rd Suite 600W
Dallas TX 75244
8901 Carpenter Frwy., Suite #100
Dallas, Texas 75247
(214) 630-1010
Report Date: April 12, 2002
Project: Northpoint Drive &
Associated Utilities
Coppell, Texas
Project Number: 94021061
Material Information Lab Test Data Proiect Requirements
Optimum Max. Lab Water
Water Dry Unit Content Minimum Dry
Material Laboratory Content Weight Range Unit Weight
No. Test Method Description and Classification (%) (pct') (%) (% compaction)
1. 210610004 ASTM D 698 Reddish brown silty clayey sand
11.8 117.0 -1/+3 95
Field Test Data Probe Water Dry Unit Dry Unit
Test Lift/ Mat. Depth Content Weight Weight
No. Test Location Elevation No. (inches) (%) (pct') (% compaction)
Storm Sewer, Line A
86 Sra. 5+50 1st 1 6 11.7 114.3 98
87 Sra. 5+55 2nd 1 6 11.4 112.8 96
88 Sta. 5+60 3rd/Final 1 6 11.8 111.8 96
89 Sta. 7+00 1st I 6 12.1 113.7 97
90 Sta. 6+95 2nd 1 6 12.3 114.6 98
91 Sra. 6+90 3rd/Final I 6 11.6 114.9 98
Comments:
Test ~esults on this report meet project specification,
Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture
condition.
Field Test Method:ASTM D2922, ^STM D3017
Gauge ID:
Field Results Reported To: Contractor/Moss
Technician: Brad Rengstorff
Report Distribution:
(1) Transwestem Commercial Services (1) City of Coppell - Bldg Insp
(1) Glenn Thurrnan Inc (1) State Farm Insurance
(1) Halff Associates (1) Moss Construction
Reviewed by:
Principal
(1) City of Coppell - Engineering
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of I
FIELD DENSITY TESTING
Report Number: 94021061.0020
Service Date: March 23, 2002
Client: Transwestern Commemial Services
Attn: Jim Gaspard
5001 Spring Valley Rd Suite 600W
Dallas TX 75244
8901 Carpenter Fn~vy., Suite #100
Dallas, Texas 75247
(214) 630-1010
Report Date: April 12, 2002
Project: Northpoint Drive &
Associated Utilities
Coppell, Texas
Project Number: 94021061
Material Information Lab Test Data Project Requirements
Optimum Max. Lab Water
Water Dry Unit Content Minimum Dry
Material Laboratory Content Weight Range Unit Weight
No. Test Method Description and Classification (%) (pct') (%) (% compaction)
1. 210290004 ASTM D-698 Dk brown clay 22.4 99.9 -1t+3 95
Field Test Data Probe Water Dry Unit Dry Unit
Test LiftJ Mat. Depth Content Weight Weight
No. Test Location Elevation No. (inches) (%) (pct') (% compaction)
Water Line, Line B
34 Sta. 5+25 1st I 6 23.8 97.3 97
35 Sta. 5+30 2nd 1 6 22.7 96.5 97
36 Sta. 6+70 1st 1 6 24.9 95.2 95
37 Sta. 6+75 2nd 1 6 23.8 98.3 98
38 Sta. 8+25 1st 1 6 25.6 * 96.3 96
39 Sta. 8+30 2nd 1 6 23.7 97.6 98
Comments:
An asterisk (*) appears next to test results which do NOT meet the project specifications.
Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture
condition.
Field Test Method:ASTM D2922, ASTM D3017
Gauge ID:
Field Results Reported To: Contractor/Moss
Technician: Brad Rengstorff
Report Distribution:
(1) Transwestem Commercial Services (1) City of Coppell - Bldg Insp
(1) Glenn Thurman Inc (1) State Farm Insurance
(1) Haiff Associates (1) Moss Construction
Reviewed by:
Principal
(1) City of Coppell- Engineering
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 1 ~o~7~,~
FIELD DENSITY TESTING
Report Number: 94021061.0009
Service Date: March 22, 2002
Client: Transwestem Commercial Services
Attn: Jim Gaspard
5001 Spring Valley Rd Suite 600W
Dallas TX 75244
8901 Carpenter Frwy., Suite #100
Dallas, Texas 75247
(214) 630-1010
Report Date: April 12, 2002
Project: Northpoint Drive &
Associated Utilities
Coppell, Texas
Project Number: 94021061
Material Information
Material Laboratory
No. Test Method
Description and Classification
Lab Test Data Project Requirements
Optimum Max. Lab Water
Water Dry Unit Content Minimum Dry
Content Weight Range Unit Weight
(%) (pcf) (%) (% compaction)
1. 210290004 ASTM D-698 Dk brown clay 22.4 99.9 -1/+3
Field Test Data Probe Water Dry Unit
Test Lift/ Mat. Depth Content Weight
No. Test Location Elevation No. (inches) (%) (pcf)
Water Line, Line B
28 Sta. 0+75 1st 1 6 23.6 96.4
29 Sta. 0+80 2nd 1 6 21.9 97.8
30 Sta. 2+50 1st 1 6 24.2 98.7
31 Sta. 2+55 2nd 1 6 22.3 95.8
32 Sra. 4+05 1st I 6 23.8 96.2
33 Sra. 4+10 2nd 1 6 22.6 96.7
95
Dry Unit
Weight
(% compaction)
96
98
99
96
96
97
Comments:
Test results on this report meet project specification.
Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture
condition.
Field Test Method:ASTM D2922, ^STM D3017
Gauge ID:
Field Results Reported To: Contractor/Moss
Technician: Brad Rengstorff
Report Distribution:
(1) Transwestem Commercial Services (1) City of Coppell - Bldg Insp
(1) Glenn Thurman Inc (1) State Farm Insurance
(1) Halff Associates (1) Moss Construction
Reviewed by:
HBC~En 'n ring
Eugene Hafoour
(1) City of Coppell - Engineering Principal
The tests were performed in general accordance with applicable ASTM. AASHTO, or DOT test methods, This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon, Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page I of I
FIELD DENSITY TESTING
Report Number: 94021061.0021
Service Date: March 24, 2002
Client: Transwestem Commercial Services
Attn: Jim Gaspard
5001 Spring Valley Rd Suite 600W
Dallas TX 75244
8901 Carpenter Fn~,y., Suite #100
Dallas, Texas 75247
(214) 630-1010
Report Date: April 12, 2002
Project: Northpoint Drive &
Associated Utilities
Coppell, Texas
Project Number: 94021061
Material Information Lab Test Data Proiect Requirements
Optimum Max. Lab Water
Water Dry Unit Content Minimum Dry
Material Laboratory Content Weight Range Unit Weight
No. Test Method Description and Classification (%) (pct') (%) (% compaction)
1. 210290004 ASTM D-698 Dk brown clay 22.4 99.9 -1/+3 95
Field Test Data Probe Water Dry Unit Dry Unit
Test Lift/ Mat. Depth Content Weight Weight
No. Test Location Elevation No. (inches) (%) (pcf) (% compaction)
Water Line, Line B
40 Sta. 27+50 1 st 1 6 24.6 100.2 100
41 Sta. 27+45 2nd 1 6 25.3 98.7 99
42 Sta. 25+10 1st 1 6 22.7 99.3 99
43 Sta. 25+05 2nd 1 6 23.8 98.7 99
44 Sta. 23+45 1st I 6 21.9 99.4 99
45 Sta. 23+40 2nd 1 6 25.2 97.6 98
46 Sta. 10+50 1st 1 6 23.1 99.9 100
47 Sta. 1'0+55 2nd 1 6 24.2 100.2 100
48 Sta. 12+05 1st 1 6 23.9 100.6 101
49 Sta. 12+10 2nd 1 6 25.2 95.7 96
50 Sta. 13+40 1st 1 6 24.3 98.6 99
51 Sta. 13+45 2nd 1 6 23.9 100.3 100
Comments:
Test results on this report meet project specification.
Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture
condition.
Field Test Method:ASTM D2922, ASTM D3017
Gauge ID:
Field Results Reported To: Contractor/Moss
Technician: Brad Rengstorff
Report Distribution:
(1) Transwestem Commemial Services (1) City of Coppell - Bldg Insp
(1) Glenn Thurman Inc (1) State Farm Insurance
(1) Halff Associates (1) Moss Construction
Reviewed by:
HBC.~ring~ g~
Eugene Harbour
(1) City of Coppell - Engineering Principal
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of I
FIELD DENSITY TESTING
Report Number: 94021061.0012
Service Date: March 27, 2002
Client: Transwestern Commemial Services
Attn: Jim Gaspard
5001 Spring Valley Rd Suite 600W
Dallas TX 75244
8901 Carpenter Frwy., Suite #100
Dallas, Texas 75247
(214) 630-1010
Report Date: April 12, 2002
Project: Northpoint Drive &
Associated Utilities
Coppell, Texas
Project Number: 94021061
Material Information
Material Laboratory
No. Test Method
Description and Classification
Lab Test Data Proiect Requirements
Optimum Max. Lab Water
Water Dry Unit Content Minimum Dry
Content Weight Range Unit Weight
(%) (pct') (%) (% compaction)
1. 210610005 ASTM D 698 Brown silty clayey sand 12.6 115.6 -1/+3
Field Test Data Probe Water Dry Unit
Test Lift/ Mat. Depth Content Weight
No. Test Location Elevation No. (inches) (%) (pcf)
Storm Sewer, Lateral B-1
71 Sra. 1+00 1st 1 6 14.2 110.8
72 Sta. 1+00 2nd 1 6 15.1 111.4
73 Sta. 2+50 1st 1 6 12.3 112.6
74 Sta. 2+50 2nd I 6 12.9 113.2
75 Sta. 3+75 1st 1 6 14.6 111.6
76 Sta. 3+75 2nd 1 6 13.8 110.7
77 Sta. 5+00 1st 1 6 14.6 111.9
78 Sta. 5+00 2nd 1 6 15.2 114.2
79 Sta. 6+15 1st I 6 15.3 113.6
80 Sta. 6+15 2nd I 6 14.8 112.1
95
Dry Unit
Weight
(% compaction)
96
96
97
98
97
96
97
99
98
97
Comments:
Test results on this report meet project specification.
Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture
condition.
Field Test Method:ASTM D2922, ASTM D3017
Gauge ID:
Field Results Reported To: Contractor/Moss
Technician: Brad Rengstorff
Report Distribution:
(1) Transwestern Commemial Services (1) City of Coppell - BIdg Insp
(1) Glenn Thurman Inc (1) State Farm Insurance
(1) Halff Associates (1) Moss Construction
Reviewed by:
HBC ~ng
Eugene Harbour
Principal
(1) City of Coppell- Engineering
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
rnatedals.
Page 1 of I
FIELD DENSITY TESTING
Report Number: 94021061.0017
Service Date: March 28, 2002
Client: Transwestern Commemial Services
Attn: Jim Gaspard
5001 Spring Valley Rd Suite 600W
Dallas TX 75244
8901 Carpenter Frwy., Suite #100
Dallas, Texas 75247
(214) 630-1010
Report Date: April 12, 2002
Project: Northpoint Drive &
Associated Utilities
Coppell, Texas
Project Number: 94021061
Material Information Lab Test Data
Optimum Max. Lab
Water Dry Unit
Material Laboratory Content Weight
No. Test Method Description and Classification (%) (pcf)
Project Requirements
Water
Content Minimum Dry
Range Unit Weight
(%) (% compaction)
1. 210610005 ASTM D 698 Brown silty clayey sand 12.6 115.6 -1/+3
Field Test Data Probe Water Dry Unit
Test Lift/ Mat. Depth Content Weight
No. Test Location Elevation No. (inches) (%) (pcf)
Storm Sewer, Line B
81 Sta. 0+50 1st/Final 1 6 13.4 112.6
82 Sra. 1+10 1st/Final 1 6 13.9 113.7
95
Dry Unit
Weight
(% compaction)
97
98
Comments:
Test results on this report meet project specification.
Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture
condition.
Field Test Method:ASTM D2922, ASTM D3017
Gauge ID:
Field Results Reported To: ContractodMoss
Technician: Brad Rengstorff
Report Distribution:
(1) Transwestem Commercial Services (1) City of Coppell - Bldg Insp
(1) Glenn Thurman Inc (1) State Farm Insurance
(1) Halff Associates (1) Moss Construction
Reviewed by:
Eugene Hart)our
Principal
(1) City of Coppell - Engineering
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of I
CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94021061.0016
Service Date: March 26, 2002
Client: Transwestern Commercial Services
Attn: Jim Gaspard
5001 Spring Valley Rd Suite 600W
Dallas TX 75244
Report Date: April 12, 2002
Project: Northpoint Drive &
Associated Utilities
Coppell, Texas
Project Number: 94021061
EN1GINE, E i~.ING
8901 Carpenter Frwy., Suite #100
Dallas, Texas 75247
(214) 630-1010
Material Information
Specified Strength:
Batch Time: N/A
Supplier: N/A
Truck No: N/A
Mix I.D. No.: N/A
Plant: N/A
Field Test Data
Test
Slump, inches:
Air Content, %:
Concrete Temperature,° F:
Ambient Temperature, o F:
Plastic Unit Weight, pcf:
Laboratory Test Data
Set Specimen Diameter
No. ID (inches)
Ticket No: N/A
Sample Information
sample Time: N/A Date Cast: March 14, 2002
Technician: Contractor Made
Weather Conditions: N/A
Accumulative Yards: N/A
Placement Method: N/A
Sample Locations: MH Sta. 12+51.39 Line C
Placement Location: Sanitary Sewer
Result Specification Test Method
N/A N/A ASTM C-143
N/A N/A
N/A ASTM C1064
N/A ASTM C-1064
Age at Maximum Compressive
Area Date Test Load Strength
(sq. inches) Tested (days) (lbs) (psi)
I I 6.00 28.27 03/27/2002 13 101,700 3,600
1 2 6.00 28.27 03/27/2002 13 100,700 3,560
Average 3,580
1 3 6.00 28.27 04/11/2002 28 125,860 4,450
1 4 6.00 28.27 04/11/2002 28 128,740 4,550
Average 4,500
Services -
Pick up test cylinders cast by others and return them to the laboratory for curing and testing.
Technician: Brad Rengstorff
Report Distribution:
(1) Transwestern Commercial Services
(1) Glenn Thurman
(1) Halff Associates
(1) City of Coppell- Bldg Insp
(1) State Farm Insurance
(1) Moss Construction
Reviewed by:
HBC Eng~
Eugene Harbour
(1) City of Coppell - Engineering Principal
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods, This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials. Page 1 of 1 o~ ~,~,~o,
FIELD DENSITY TESTING
Report Number: 94021061.0011
Service Date: March 26, 2002
Client: Transwestern Commercial Services
Attn: Jim Gaspard
5001 Spring Valley Rd Suite 600W
Dallas TX 75244
8901 Carpenter Frwy., Suite #100
Dallas, Texas 75247
(214) 630-1010
Report Date: April 12, 2002
Project: Northpoint Drive &
Associated Utilities
Coppell, Texas
Project Number: 94021061
Material Information Lab Test Data Project Requirements
Optimum Max. Lab Water
Water Dry Unit Content Minimum Dry
Material Laboratory Content Weight Range Unit Weight
No. Test Method Description and Classification (%) (pcf) (%) (% compaction)
1. 210290004 ASTM D-698 Dk brown clay 22.4 99.9 -1/+3 95
Field Test Data Probe Water Dry Unit Dry Unit
Test Lift/ Mat. Depth Content Weight Weight
No. Test Location Elevation No. (inches) (%) (pcf) (% compaction)
Water Line, Lateral Line B
64 Sta. 10+15 Final 1 6 24.4 95.7 96
65 Sra. 15+06 Final 1 6 23.7 96.3 96
66 Sta. 17+18 Final 1 6 22.6 99.3 99
67 Sra. 21 +11 Final 1 6 23.8 97.3 97
68 Sta. 23+79 Final 1 6 24.9 96.1 96
69 Sra. 26+45 Final I 6 25.3 98.4 98
70 Sra. 27+03 Final 1 6 25.1 97.2 97
Comments:
Test results on this report meet project specification.
Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture
condition.
Field Test Method~,STM D2922, ASTM D3017
Gauge ID:
Field Results Reported To: Contractor/Moss
Technician: Brad Rengstorff
Report Distribution:
(1) Transwestern Commercial Services (1) City of Coppell - Bldg Insp
(1) Glenn Thurman Inc (1) State Farm insurance
(1) Halff Associates (1) Moss Construction
Reviewed by'
HBC En~g
Eugene Harbour
(1) City of Coppell - Engineering Principal
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This repod is exclusively for the usa of the client
indicated above and shall not be reproduced except in fult without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 1 0~ s~.~oT~,
FIELD DENSITY TESTING
Repo[t Number: 94021061.0010
Service Date: March 25, 2002
ENGINEERING
8901 Carpenter Frwy., Suite #100
Dallas, Texas 75247
(214) 630-1010
Client: Transwestern Commercial Services
Attn: Jim Gaspard
5001 Spring Valley Rd Suite 600W
Dallas TX 75244
Report Date: April 12, 2002
Project: Northpoint Drive &
Associated Utilities
Coppell, Texas
Project Number: 94021061
Material Information Lab Test Data Proiect Requirements
Optimum Max. Lab Water
Water Dry Unit Content Minimum Dry
Material Laboratory Content Weight Range Unit Weight
No. Test Method Description and Classification (%) (pcf) (%) (% compaction)
1. 210290004 ASTM D-698 Dk brown clay 22.4 99.9 -1/+3 95
Field Test Data Probe Water Dry Unit Dry Unit
Test Lift/ Mat. Depth Content Weight Weight
No. Test Location Elevation No. (inches) (%) (pct') (% compaction)
Water Line, Line B
52 Sta. 22+05 1st 1 6 21.7 99.3 99
53 Sta. 22+00 2nd 1 6 21.4 98.1 98
54 Sta. 20+45 1st 1 6 23.6 97.3 97
55 Sra. 20+40 2nd 1 6 23.8 99.6 100
56 Sra. 18+10 1st 1 6 24.2 97.2 97
57 Sta. 18+05 2nd 1 6 24.7 97.3 97
58 Sta. 16+50 1st 1 6 23.2 99.2 99
59 Sta. 16+45 2nd 1 6 24.8 96.8 97
60 Sta. 15+05 1st 1 6 24.7 96.3 96
61 Sta. 15+10 2nd 1 6 25.1 95.6 96
Water Line, Lateral Line B
62 Sta. 6+54 Final 1 6 22.7 100.6 101
63 Sta. 9+06 Final 1 6 23.3 101.2 101
Comments:
Test results on this report meet project specification.
Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture
condition.
Field Test Method~,STM D2922, ASTM D3017
Gauge ID:
Field Results Reported To: ContractodMoss
Technician: Brad Rengstodf
Report Distribution:
(1) Trenswestern Commercial Services (1) City of Coppell - Bldg Insp
(1) Glenn Thurrnan Inc (1) State Farm Insurance
(1) Halff Associates (1) Moss Construction
Reviewed by:
Eugene Harbour
(1) City of Coppell - Engineering Principal
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 1 o~..~s~o7
FIELD DENSITY TESTING
Report Number: 94021061.0018
Service Date: March 29, 2002
8901 Carpenter Frwy., Suite #100
Dallas, Texas 75247
(214) 630-1010
Client: Transwestern Commercial Services
Attn: Jim Gaspard
5001 Spring Valley Rd Suite 600W
Dallas TX 75244
Report Date: April 12, 2002
Project: Northpoint Drive &
Associated Utilities
Coppell, Texas
Project Number: 94021061
Material Information Lab Test Data Project Requirements
Optimum Max. Lab Water
.Water Dry Unit Content Minimum Dry
Material Laboratory Content Weight Range Unit Weight
No. Test Method Description and Classification (%) (pct~ (%) (% compaction)
1. 210610004 ASTM D 698 Reddish brown silty clayey sand 11.8 117.0 -1/+3 95
Field Test Data Probe Water Dry Unit Dry Unit
Test LiflJ Mat. Depth Content Weight Weight
No. Test Location Elevation No. (inches) (%) (pct~ (% compaction)
Storm Sewer, Line A
83 Sta. 3+00 1st/Final 1 6 10.7 * 113.7 97
84 Sta. 4+00 1st 1 6 11.2 112.8 96
85 Sra. 4+00 2nd/Final 1 6 11.6 114.6 98
Comments:
An asterisk (*) appears next to test results which do NOT meet the project specifications.
Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture
condition.
Field Test Method:ASTM D2922, ASTM D3017
Gauge ID:
Field Results Repoded To: Contractor/Moss
Technician: Brad Rengstodf
Report Distribution:
(1) Transwestern Commercial Services
(1) Glenn Thurman Inc
(1) Halff Associates
(1) City of Coppetl - Engineering
(1) City of Coppell - Bldg Insp
(1) State Farm Insurance
(1) Moss Construction
Reviewed by:
HBC En~ng
Eugene Harbour
Principal
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 1 ~ sos~07