Loading...
WA9302A-SP 960528. North Texas Municipal Construction Company, Inc. SUBMITTAL NO. 04000-03 5614 Dyer St. Dallas, Texas 75206 City of Coppoll 214/368-6880 Village Parkway Pump Station FAX 214/368-4950 "Certification Statement: By this submittal. t hereby represcnL that [ have determined and verified all fieid measurements, field constructions criteria, materials. dimension::, catalog numbers and similar data and [ have checked and c~.ordinated each item with other applicable approved Shop Drawings and all Contract requirements.' NORTH TE~S MUNICIPAL "ONSTRUCTION COMPANY, INC. i · ~AKE CORRECTIONS NOTED [] REJECTED [] R-EVISE AND RESUBMIT [] SUBMIT SPECIFIED ITEM Checking Is only for general conformance with the desl&m concept of the project and general compliance with the information given in the contract documents- Any action shown is subject to the requirements of the plans and specifications. Contractor is responsible for: dimensions which shall be confirmed and correlated at the iob site; fabrication processes and techniques of construction, co- ordination of his work with that of all other trades and .performing his work in a safe and satisfactorY manner. SHIMEK, JACOBS & FINKLEA CONSULTING ENGINEERS DALLAS, TEXAS CONSTRUCTION * SALES * SERVICE ~. "'.DALLAS CAST STONE CO., .'INC. - 4107 Hancock St. - Dallas, Texas 75210 -(214)428-8269 Contr.ctor H-'T- _T-,] Dgte ............... ~ .... ~1/~ , .:,, ............................ ~_ - II .,DALLAS-CAST STONE CO.', .iNC..- 4107 Hancock St. - Dallas, Texas 75210 -(214)428-626g MTI MASONRY TECHNOLOGY, INC. May 20, 1996 North Texas Municipal Const. Co. 5614 Dyer Street Dallas, Texas 75206 Attn: Bill Bigham Re: Village Parkway Pump Station Coppell, Texas Type "S" Mortar Design Gentlemen: Our mortar for above grade use shall be Type "S" . Per ASTM 270 the mix shall consist of 1 part Portland Cement, ~ to ~A part Hydrated Lime, and 4~/~ parts Sand. If there are any questions or comments regarding this matter, please contact this office. Sincerely, MASONRY TECHNOLOGY, INC. WTW/dw xc: Submittal #2 File MA,'L i,',G ,aDD~qE 55 S Ti~£ F 7 ~aD~n~'E S S ~' ~" -E44~ PO BOX 280477 4101 SOUTH SHILOH ROAD MEMBE~ M~SON CON]R~TC:E 328-1039 DALLAS. TEXAS 7522E-9077 GARLAND. TEXAS 7504 1 ASEQg~TION OF AMERICA MTI MASONRY TECHNOLOGY, INC. May 20, 1996 North Texas Municipal Const. Co. 5614 Dyer Street Dallas, Texas 75206 Attn: Bill Bigham Re: Village Parkway Pump Station Job No. M1262 Coppell, Texas Mortar Mix Design for Grout Gentlemen: We propose to supply grout as required for this project per ASTM C476. The fine grout shall consist of 1 part Portland Cement, no more than 1/10 part Hydrated Lime, and 2 ~ to 3 parts fine aggregate. The course grout shall consist of 1 part Portland Cement, no more than 1/10 pan Hydrated Lime, 2 ~ to 3 pans f'me aggregate, and 1 to 2 pans course aggregate. If there are any questions or comments regarding this matter, please contact this office. Sihcerely, ~// MASONRY TECHNOLOGY, INC. Project Manager WTW/dw xc: Submittal #3 File M,llfLIIVG .t, DE~RESS STREET ~DDRESS 321-6443 RO. BOX 28~77 4101 SOUTH SHILOH ROAD MEMBER M~SON CONTRACTORS ~;~. (214) 328-1029 DALLAS. TEXAS 75228-9077 GARLAND. TEXAS 75~I ASSOCIAI~ON OF AMER:CA Lox A!I® Adj usta bl res . "lADDER TYPE' ~270 · AJlows construction .of interior wythe "-'-"" Ily mason backu . -, · Available mill galvanized, hot dip galvanized, or stainless steel. Shod SpeCifiCCltiOrl facturea by HOHMANN & BARNARD, INC., · Rejnforcina f~r interior w~he Can be Where horizontal mortar joints do not Hauppauge, NY, or approved eCIUQI. TNDARi5WEIGHT (9 ga. x 9 ga;~g align in composite, cavity or insulated *When ordering HOHMANN & BARNARD RA HEAVY~3/16" 5iae i~oas x a. walls, or when interior wythe is to be con- EYE-WIRE, slate block width, cavity size, Cross Rods), or SUPER HEAVY DUTY structed before exterior _wythe, reinforce- thickness of insulation (if any), and (all 3/'16'). Eyes and Pinties are 3/q6" ment shall be LOXOALI. ,e~:)JUSTABLE brick width. Eyes are welded 16" o~. did. standard. EYE-WIRE (truss or ladder type) as manu- H & B recommends Type 3(:: ~, or Type 316 Stainless Steel Rectangular Adjustable Wall Ties for maximum protection ag Jinst corrosion. Adjustable Wall Tie 00MPLFTE 11E PiNTIE SECTION ~ S[-C110N ' '; ' ' ' ~ 600 6' 325H 3~A' 275E 23~· 750 74' 475H 434' 275E 23A' 800 8' 325H 31~· 475E 800A 8' 525H 51A· 275E 23A' 950 94' 475H 4~' 475E 43,~' 1000 10' 525H 5~A' 475E 43,~' Available mill galvanized, hot dip galvanized. or stainless steel. HB HOOK-IT- Adjustable Two Wythe Wall Reinforcement · Reinforces both inner and outer - .:-' i;~..~ Hook-It-2 .. . wythes and provides vertically -~ Reinforcement adjustable ties between them. '- ~ ~ nd t he · Non-aligned bed joints are -, do no~ oS~. compensated for, and telltale joint I~ variations are eliminated because the masoO no longer has to force "' brick under rigidly fixed reinforcing. //; · The box portion does not clog with , mortar and a certain ai'fiount of ~: longitudinal adjustment is provided. can be fevef!~cI to~ illcradled Odi-dltalc~l~y. · Projecting box portions hold rigid -, insulation in place while the hook ~B;~ holds it against the back-up. an 3/16" DIA. HOOKS U 46'~°O'C' EaCh Way 6 inexpensive securing system. · Labor savings more than make up up for the slight additional cost of Reinforcemenl for Inner and outer wythes available material... and you get a beHer In any combination of ladder or truss types, job in addition. · Mill Galv./Hot Dip Gafv./Stainl~ss Steel · q ga. or 3/q6" did. Side Rods , · 9 ga or 3/16" dia. Cross Rods J !-1/2" · 3/I~'' did x 2" wide Boxes .s. Patent 3,964,22