Amberpoint BP-LR020422 (2)CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0214 Service Date: April 15, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 Report Date: April 22, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Ma terial In formation Specified Strength: 3000 psi @ 28 Days Batch Time: 10:04am Plant: 16 Supplier: Potter Truck No: 102 Mix I.D. No.: 9337 Ticket No: 612967 70 Sample Information Sample Time: 10:30am Date Cast: April 15, 2002 Technician: Gerry Graham Weather Conditions: Cloudy Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: Pier G.7-11 Placement Location: Pier G.7-11, H.4-11, J.4-11 Field Test Data Test Result Specification Test Method Slump, inches: 5.75 6-7 ASTM C-143 Air Content, %: N/A Concrete Temperature,° F: ASTM C1064 Ambient Temperature, o F: ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Set Specimen Diameter Area Date Test No. ID (inches) (sq. inches) Tested (days) 1 I 6.00 28.27 04/22/2002 7 1 2 6.00 28.27 04/22/2002 7 Average 1 3 05/13/2002 28 1' 4 05/13/2002 28 Maximum Compressive Load Strength (lbs) (psi) 104,380 3,690 107,380 3,800 3,750 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Gerry Graham Report Distribution: (1) Transwestern Commercial Services (1) O'Brien & Associates Inc (1) TechniStructures Inc (1) City of Coppell - Constr Insp (1) City of Coppell- Bldg Insp (1) Hill & Wilkinson Ltd (1) Halff Associates (1) State Farm Insurance Reviewed by: HBC Enginee_~ Eugene Harbour Principal The tests were performed in general accordance with applicable ASTM. AASHTO, or DOT test methods. This report is exclusively for the use or,he client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 °' ~'~°' CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0209 Service Date: April 12, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 Report Date: April 22, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. (~ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 10:33am Plant: 16 Supplier: Potter Truck No: 112 Mix I.D. No.: 9337 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Ticket No: 612914 Sample Information sample Time: 10:45am Date Cast:April 12, 2002 Technician: Gerry Graham Weather Conditions: Fair, clear Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: A/1 and A/1.5 Placement Location: Piers Result Specification Test Method 6.25 5-7 ASTM C-143 2.6 N/A ASTM C-231 77 ASTM C1064 72 ASTM C-1064 Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 I 6.00 28.27 04/19/2002 7 99,900 3,530 1 2 6.00 28.27 04/19/2002 7 97,240 3,440 Average 3,490 1 3 05/10/2002 28 1 4 05/10/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Gerry Graham Report Distribution: (1) Transwestern Commercial Services (1) O'Brien & Associates (1) TechniStructures Inc (1) City of Coppell - Constr Insp (1) City of Coppell - Bldg Insp (1) Hill & Wilkinson Ltd (1) Halff Associates (1) State Farm Insurance Reviewed by: HBC Engineering Eugene~Harbour Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the c~ient indicated above and shall not be reproduced except in tull without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the propedies of other apparently similar or identical materials. Page 1 of 1 °~ LLW~Ol F~ CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0203 Service Date: April 11,2002 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 8901 Carpenter Frwy., Suite#100 Dallas, Texas 75247 (214) 630-1010 Report Date: April 22, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. (~ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 11:55am Supplier: Potter Truck No: - 1888 Mix I.D. No.: 9337 Plant: 29 Ticket No: 42483 Sample Information sample Time: 1:00pm Date Cast: April 11,2002 Technician: Steve Campbell Weather Conditions: Clear Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: Pier N-2 Placement Location: Piers M-2, N-2, 0-2 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data set specimen No. ID 1 1 1 2 I 3 I 4 Services - Result Specification Test Method 5.00 6-7 ASTM C-143 1.1 None ASTM C-231 ASTM C1 O64 75 ASTM C-1064 76 Age at Maximum Compressive Diameter Area Date Test Load Strength (inches) (sq. inches) Tested (days) (lbs) (psi) 6.00 28.27 04/18/2002 7 87,200 3,080 6.00 28.27 04/18/2002 7 94,800 3,350 Average 3,220 05/09/2002 28 05/09/2002 28 Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Steve Campbell Repod Distribution: (1) Transwestern Commercial Services (1) O'Brien & Associates Inc (1) TechniStructures Inc (1) City of Coppell - BIdg Insp (1) Hill & Wilkinson Ltd (1) Halff Associates Reviewed by: HBC En~ Eugene Harbour Principal (1) City of Coppell - Constr Insp (1) State Farm Insurance The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test resutts transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarity indicative of the propedies of other apparently similar or identical materiats. Page 1 of 1