Loading...
ST0001-LR020422RoneEn gineers 8908 Ambassador Row Dallas, Texas 75247-4510 (214) 630-9745 (2141630-9819 (fax) IN-PLACE DENSITY TESTING Client: City of Coppell Attn: Ms. Susan Taylor - Engineering Dept PO Box 478 Projectl~ '~.l~Parkway Coppell, TX Services: Perform In-Place Density Test in accordance with ASTM Standards. PROJECT DATA Report No.: 147799 Project No.: 015729 Date of Service: 04/16/2002 Report Date: 04/22/2002 CONTRACTOR: Infrastructure Services, Inc. Test Methods: ASTM D-2922 ASTM D-3017 M/l) No. Description Dark Brown Clay (Lime Treated) Gauge: Troxler 3430 Moisture Gauge Serial No: 32685 Current: 678 Test Mode: DT Previous: 636 MOISTURE DENSITY RELATIONS Maximum Moisture % Density pcf 31.0 85.0 FIELD DENSITY TESTS Standard Counts Density Current: 3132 Previous: 2997 Project Requirements Moisture Density Optimum +5 95 rain TEST PROBE NO TEST LOCATION DEPTH M/D MOISTURE WET DENSITY DRY DENSITY No. t%) (pc0 (pcf} Paving Subgrade I Creekview westbound lane, Station 1+00 6" 1 32.2 Paving Subgrade 2 Creekview eastbound lane, station 3+00 6" 1 34.9 Test results on this report meet project specification. Technician: Joe Jernigan Report Distribution: (I) City of Coppell (1) City of Coppell Started: 9:00AM Finished: ll:00A (1) City of Coppell (1) Schrickel, Rollins & Assoc., Inc. 112.6 85.2 116.4 86.3 Project Manager DENSITY (% max) I00 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided ~br testing. We assonle no responsibility for variation ~ quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our betters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Inc. 07DF Page I of I 8908 Ambassador Row Dallas, Texas 75247-4510 (214) 630-9745 (214) 630-9819 (fax) REPORT OF LIME DEPTH CHECKS Client: City of Coppell Arm: Ms. Susan Taylor - Engineenng Dept PO Box 478 Coppell TX 75109 Projeet: Creekview Drive and Freeport Parkway Coppell, TX Services: Lime Depth Cheeks Report No.: 147800 Project No.: 015729 Date of Service: 04/16/2002 Report Date: 04/22/2002 Report of Test On this date, a Rone Engineers, Inc. representative was on site to perform Lime Depth Checks on the following locations. Location Result Creekview, Station 1+00 Creekview, Station 3+00 8.75" Technician Time: See report #147799 Page 1 of 1 Technician: Joe Jemigan Report Distribution: (1) City of Coppell (1) City of Coppell (1) City of Coppell (1) Infrastructure Services, Inc. (1) Schrickel, Rollins & Assoc., Inc. Project LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Inc. 99DK Page 1 of 1 8908 Ambassador Row Dallas, Texas 75247=4510 (214) 630-9745 (214) 630-9819 (fax) IN-PLACE DENSITY TESTING Client: Project: Services: City of Coppell Arm: Ms. Susan Taylor - Engineering Dept PO Box 478 Coppell TX 75109 Creekview Drive and Freeport Parkway Coppell, TX Perform In-Place Density Test in accordance with ASTM Standards. Report No.: 148002 Project No.: 015729 Date of Service: 04/18/2002 Report Date: 04/22/2002 PROJECT DATA CONTRACTOR: Test Methods: M/D No. Infrastructure Services, Inc. ASTM D-2922 ASTM D-3017 Description Gauge: Troxler 3430 Moisture Gauge Serial No: 32685 Current: 642 Test Mode: DT Prevlons: 636 MOISTURE DENSITY RELATIONS Maximum Moisture % Density pcf Dark Brown Clay (Lime Treated) 31.0 85.0 Standard Counts Density Current: 3008 Previous: 3019 Project Requirements Moisture Density Optimum +5 95 mia FIELD DENSITY TESTS TEST NO PROBE TEST LOCATION DEPTH M/D MOISTURE WET DENSITY DRY DENSITY DENSITY No. (%) (pc/) (PoD (% max) Paving Subgrade Westbound approach, main entrance, 6" 1 32.4 Wagon Wheel Park, middle Test results on this report meet project specification. Technician: Joe Jernigan Report Distribution: (1) City of Coppell (1) City of Coppell (1) City of Coppell (1) Infrastructure Services, Inc. Started: 9:30am Finished: 1 l:30a 113.9 86.0 101 (1) City of Coppell (1) Sckrickel, Rollins & Assoc., Inc. Clay Stark Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Inc. 07DK Page 1 of 1 8908 Ambassador Row Dallas, Texas 75247-4510 (214) 630-9745 (214) 630-9819 (fax) REPORT OF CYLINDER CANCELLATION Client: City of Coppell Attn: Ms. Susan~incering Dept Servi~cellation Report No.: 147709 Project No.: 015729 Date of Service: 04/15/2002 Report Date: 04/22/2002 Report of Cancellation On this date a Rone Engineers, Inc. representative arrived on site as scheduled. Upon arrival our representative was informed that testing/inspection was cancelled for the day. Technician Time: Page 1 of 1 7:00 am to 8:00 am Technician: Anthony Maldonado Report Distribution: (1) City of Coppell (1) City of Coppell LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Inc. 99CM Page 1 of 1 R°neEngineers Client: City of Coppell Attn: Ms. Susan Taylor - Engineering Dept PO Box 478 Coppell TX 75109 Project: Creekview Drive and Freeport Parkway Coppell, TX Services: Cylinder Collection 8908 Ambassador Row Dallas, Texas 752474510 (214} 630-9745 (214) 630-9819 (fax) REPORT OF CYLINDER COLLECTION Report No.: 147306 Project No.: 015729 Date of Service: 04/06/2002 Report Date: 04/22/2002 Report of Collection On this date, a Rone Engineers, Inc. representative arrived on site as scheduled to pick up compressive strength test specimen cast prior to this date. Technician Time: Page 1 of 1 Technician: Cody Carroll Report Distribution: (1) City of Coppell (1) City of Coppell (1) City of Coppell (1) Infrastructure Services, Inc. 8:00 am to 10:00 am (1) City of Coppcll (1) Schrickel, Rollins & Assoc., Inc. Clay Stark Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Inc. 99CIM Pa£e 1 of 1