Loading...
CF-Coppell Rd SC-LR020411Hooper Engineering Laboratories, Inc. Construction Materials Testing REPORT OF CONCRETE TESTS CLIENT: Texas Unified C0nstruct~ PROJECT: Field ~ervice Offices & Ma~-~E. Fac., C0ppell JOB NO.: 01.1054 DATE: 11 April 2002 SUPPLIER: Lattimore Curb and gutter at southwest parking area, west property line LOCATION OF POUR SET 1: LOCATION OF POUR SET 2: SAMPLE DATA: SET 1 SET 2 MIX NO. Truck No. i 093 Cement Ticket No. 7115327 Flyash Time Batched 10:17am Sand Time Sampled 11:20am in. Concrete Temp. (ASTM C1064) 78°F 1.0 in. Air Content (ASTM C231} 2.8% Water Unit Weight IASTM C138) Admix //1 Admix //2 AEA 64 COMPRESSIVE STRENGTH TESTS (ASTM C39) (Standard 6 inch x 12 inch cylinder) Cylinder Slump Age Test Total Load Compressive Required Number Inches Days Date Pounds Strength 28-Day (ASTM C143) psi Strength 1 98 3.50 7 04/1 8/02 1 99 3.50 28 05/09/02 200 3.50 28 05/09/02 101,400 3590 28-Day Average 3500 TECHNICIAN: DISTRIBUTION: RJW (10:30am-12:30pm) (1) Vidaud & Associates (1) Doyle Engineering Group (1) Texas Unified Constructors, 2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148