Amberpoint BP-LR020424 (2)CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0159 Service Date: March 27, 2002 Client: Transwestem Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Repo~ Pr ' Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 3000 psi (~ 28 Days Batch Time: 9:08am Supplier: Potter Truck No: 101 Mix I.D. No.: 9337 Plant: 16 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 6.25 61 54 Set Specimen Diameter Area No. ID (inches) (sq. inches) I 1 6.00 28.27 1 2 6.00 28.27 1 3 6.00 28.27 I 4 6.00 28.27 Ticket No: 612349 Sample Information Sample Time: 9:19am Date Cast: March 27, 2002 Technician: Gerry Graham Weather Conditions: Fair Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: Fl10, 1/8, I/9 & 1/10 Placement Location: Piers Specification Test Method 5-7 ASTM C-143 N/A ASTM C1064 ASTM C- 1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 04/03/2002 7 119,910 4,240 04/03/2002 7 120,250 4,250 Average 4,250 04/24/2002 28 157,090 5,560 04/24/2002 28 165,700 5,860 A?r~ ~ 5,710 Services - Obtain samples of fresh concrete at the placement locations, perform.~]~ired ~1~sts' and cast compressive strength samples. Technician: Gerry Graham HBC FJ~g Report Distribution: (1) Transwestern Commercial Services (1) City of Coppell - BIdg Insp Reviewed by: (1) O'Brien & Associates Inc (1) Hill & Wilkinson Ltd (1) TechniStructures Inc (1) Halff Associates Eugene Harbour (1) City of Coppefl - Constr Insp (1) State Farm Insurance Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 0, L~w,.0~ REPORT OF DRILLED BELLED PIER OBSERVATION Report Number: 94021029.0228 Service Date: April 19, 2002 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: April 24, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Services: Drilled belled pier observation On this date, an HBC Engineering technician arrived at the above referenced jobsite as scheduled for drilled belled pier observation. See the attached sheet(s) for recorded data. Technician: Steve Campbell .. j HBC Engine i Report Distribution: (1) Transwestern Commercial Services (1) City of Coppell- Bldg Insp (1) O'Brien & Associates Inc (1) Hill & Wilkinson Ltd Reviewed by: Eugene (1) TechniStructures Inc (1) Halff Associates (1) City of Coppell ~ Constr Insp (1) State Farm Insurance Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 ~gL~w~,~y