Deforest Court-LR020429CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021129.0010 Service Date: April 18, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: The Holmes Builders Attn: Dean Trudell 1406 Halsey Way Suite 100 Carrollton TX 75007 Report Date: April 29, 2002 Project: Single Family Home ~ 632 De___Fores_t Court Project Number: 94021129 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 4:15pm Supplier: Redi-Mix Truck No: 217 Mix I.D. No.: 914 Plant: 1 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Ticket No: 17343 Sample Information Sample Time: 5:15pm Date Cast:April 18, 2002 Technician: Phil Green Weather Conditions: Cloudy, warm Accumulative Yards: 30 Placement Method: Crane & Bucket Sample Locations: Pier #23 Placement Location: Piers Result Specification Test Method 4.00 5-7 ASTM C-143 1.7 N/A ASTM C-231 87 ASTM C1064 85 ASTM C-1064 Age at Test (days) Set Specimen Diameter Area Date No. ID (inches) (sq. inches.) Tested 1 1 6.00 28.27 04/25/2002 I 2 6.00 28.27 04/25/2002 7 Average 1 3 05/16/2002 28 1 4 05/16/2002 28 Maximum Compressive Load Strength (lbs) (psi) 75,350 2,660 73,740 2,610 2,640 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Phil Green Report Distribution: (1) The Holmes Builders (1) City of Coppell - Constr Insp (1) City of Coppell- Bldg Insp Reviewed by: HBC Engineering Hussein H. Abusaad, P.E. Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021129.0012 Service Date: April 19, 2002 8901 Carpenter Envy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: The Holmes Builders Attn: Dean Trudell 1406 Halsey Way Suite 100 Carrollton TX 75007 Report Date: April 29, 2002 Project: Single Family Home 632 DeForest Court Coppell, Texas Project Number: 94021129 Material Information Specified Strength: 3000 psi @ 26 Days Batch Time: 3:45pm Supplier: Redi-Mix Truck No: 108 Mix I.D. No.: 914 Plant: 1 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Ticket No: 17410 Sample Information Sample Time: 5:30pm Date Cast:April 19, 2002 Technician: Phil Green Weather Conditions: Overcast Accumulative Yards: 30 Placement Method: Crane & Bucket Sample Locations: Pier #37 Placement Location: Piers Result Specification Test Method 3.00 5-7 ASTM C-143 2.2 N/A ASTM C-231 88 ASTM C1064 87 ASTM C-1064 Age at Set Specimen Diameter Area Date Test No. ID (inches) (sq. inches) Tested (days) 1 1 6.00 28.27 04/26/2002 7 1 2 6.00 28.27 04/26/2002 7 Average 1 3 05/17/2002 28 1 4 05/17/2002 28 Maximum Compressive Load Strength (lbs) (psi) 61,870 2,190 63,210 2,240 2,220 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Phil Green Report Distribution: HB~ring (1) The Holmes Builders (1) City of Coppell - Constr Insp Reviewed by: (1) city of Coppell - Bldg Insp Hussein H. Abusaad, P.E. Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 o,.~w~,